background image

22

23

• The installati on must be done by qualifi ed and experienced professionals;

• Choose where the control module will be placed. Use a multi meter to check the 

vehicle’s signals;

•  Connect  the  signal  and  power  wires  according  to  installati on  informati on  and 

availability of functi ons in the vehicle;

• Before connecti ng the control module to the electrical harness make sure there 

are no “short”.

• Do not forget to plug  the module central aft er the installati on is complete.

If you have any questi ons, please contact the dealer or the shop where installati on 

was performed, or please contact our 

SAC: 3003 1900

. Go to 

www.stetsom.com.br/

en/instaladores

 to fi nd specifi c installati on materials in diff erent vehicles.

INSTALLATION

INSTALLATION DIAGRAM

21

22

The perfect working of this product depends on the technical characteristi cs of the vehicle. 

Some functi ons or features may not apply. Actuators, modules and external relays may be 

required, not included in the alarm kit.

STETSOM

Ground

Ground

Only  program  the  automati c  closing  of  the  windows  when  the  window 

regulator  has  an  anti -pinch  device  in  accordance  with 

annex  S5  of  the 

regulati on §571.118 Standard No. 118

.

The igniti on coil and fuel pump lockout opti ons are not recommended by STETSOM 

as  they  may  compromise,  in  whole  or  in  part,  the  operati onal  performance  and 

safety of the vehicle.

If there is a need to install equipment with current consumpti on higher than that 

indicated  for  each  output  (auxiliary,  sound,  lock,  unlock,  expansion)  relays  are 

required.

RELAY INSTALLATION DIAGRAM

23

Negati ve

Signal

(Alarm)

+12V

Output

+12V

Turn 

NEGATIVE

 alarm signal 

(200mA)

 into 

POSITIVE 

+12V

.

Turn 

NEGATIVE

 alarm signal 

(200mA)

 into 

NEGATIVE

 of 

higher power.

Negati ve

Signal

(Alarm)

Negati ve 

Output

Ground

(Negati ve)

+12V

STARTING 

SWITCH 

(yellow wire)

SYSTEM TO BE 

LOCKED

SYSTEM TO BE 

LOCKED

START 

ENGINE 

(yellow wire)

+12V

(yellow wire)

ALARM

MODULE

(block)

ALARM

MODULE

(block)

Connecti on for Lock

(Corrent to 10A)

Connecti on for Lock

(Corrent greater to 10A)

(Auxiliary relay sold separately)

ULTRASOUND 

(Passenger)

ULTRASOUND 

(Driver)

HOOD 

(brown)

PLAYER/RADIO 

(purple)

AUXILIARY 

(gray)

DOOR 

(green)

IGNITION 

(blue)

OUTPUT WINDOW 

(green/black)

SIREN

(black/yellow)

+12V 

(red)

MASTER BUTTON

(black)

LOCK

 (red/yellow)

(black/green)

RIGHT BLINKER

LEFT BLINKER

UNLOCK

 (red/black)

Summary of Contents for ELT PLUS

Page 1: ...Portugu s English Espa ol Manual do Usu rio User Manual Manual de Usuario EVOLUTION LINE Alarme Automotivo CERTIFICADO DE GEST O ORGANIZACIONAL ISO 9001 2015 CERTIFIED COMPANY...

Page 2: ...omente se a fun o 10 pisca estiver habilitada 1 2 Fun o Auxiliar Por 3 segs Em seguida Ativa o alarme sem ultrassom Emite dois bips curtos EVX TOP ELT TOP I MOVE ELT PLUS L mina da chave n o inclusa P...

Page 3: ...1min e 20segs emite aviso sonoro de 10 segundos ap s o qual entra no ciclo de bloqueio 6 2 ANTIFURTO PELA IGNI O Cada vez que for ligada a igni o acionado o antifurto se a fun o 7 da tabela de progra...

Page 4: ...adquiridos separadamente Ao desativar o sistema ap s um disparo e ligar a igni o o LED pisca um n mero de vezes que indica qual a causa do disparo na ltima vez que o alarme esteve ativado Se ocorreu m...

Page 5: ...e f brica Armar Desarmar com BIPs Armar Desarmar com setas Tempo de pulso de trava 1 BIP 2 5 segs 2 BIPs 0 8 segs 12V Tempo de expans o 1 BIP 14s 2 BIPs 0 2s GM 3 BIPs VW G5 4 BIPs FIAT Antifurto pela...

Page 6: ...ro de 1996 do Conselho Nacional de Tr nsito CONTRAN As op es de bloqueio de bobina de igni o e bomba de combust vel n o s o recomendadas pela STETSOM pois poder o comprometer no todo ou em parte o des...

Page 7: ...a Marron Dourado Vermelho Preto Marron Dourado 220 Utilize resistor de 220 Ohms caso tenha problemas em encontrar de 180 Ohms Todas as partes desse produto incluindo os componentes el tricos e elet ni...

Page 8: ...ly if function 10 ashes is enabled 1 2 Auxiliary Function For 3 segs Enable alarm wi thout ultrasound Siren beeps twice EVX TOP ELT TOP I MOVE ELT PLUS Key blade not included To install the blade remo...

Page 9: ...o deactivate this anti theft function 6 3 ANTI THEFT BY PRESENCE To activate the presence function program the presence control see section 3 When the ignition is on if the control panel does not rece...

Page 10: ...turn the ignition off and on Another way to generate this signal is to press the bu on when the alarm is off The trigger given for the alarm going off remains valid until the alarm is activated again...

Page 11: ...larm with blinkers Lock pulse time 1 Beep 2 5 segs 2 Beeps 0 8 segs 12V Expansion time 1 Beep 14s 2 Beeps 0 2s GM 3 Beeps VW G5 4 Beeps FIAT Anti theft for opening the door Positive dedicated After th...

Page 12: ...ndows when the window regulator has an anti pinch device in accordance with annex S5 of the regulation 571 118 Standard No 118 The ignition coil and fuel pump lockout options are not recommended by ST...

Page 13: ...n in the image 180 Brown Gray Brown Golden Red Black Brown Golden 220 Use 220 Ohms resistor if you have trouble finding 180 Ohms Alarm Module Operating Voltage Consumption Lock Output Signal Sound Aux...

Page 14: ...ccionales est habilitada 1 2 Activa panel Por 3 segs Activa la alarma sin ultrasonido Emite dois bips curtos EVX TOP ELT TOP I MOVE ELT PLUS L mina de la llave no incluida Para instalar la espada reti...

Page 15: ...periodic transmission 5 2 BLOQUEO O DESBLOQUEO Permite configurar entre dos tiempos de bloqueo desbloqueo pulso de 0 8 segundos o 2 5 segundos Puede ser utilizado para comandar trabas el ctricas orig...

Page 16: ...deben adquirir por separado Al apagar el sistema despu s de un disparo y abrir el contacto el LED destella un n mero de veces que indica la causa del disparo la ltima vez que la alarma estuvo activad...

Page 17: ...f brica Activa Desactiva con beeps Activa desactiva con direccionales Tiempo de pulso de bloqueo 1 Beep 2 5 segs 2 Beeps 0 8 segs 12V Tiempo de expansi n 1Beep 14s 2Beeps 0 2s GM 3Beeps VWG5 4Beeps FI...

Page 18: ...a vidrios posee sistema antipinzamiento en acuerdo a las normas generales de seguridad de su pa s Las opciones de bloqueo la bobina de encendido y bomba de combustible no son recomendadas por STETSOM...

Page 19: ...arr n Dorado 220 Use una resistencia de 220 Ohms si tiene problemas para encontrar 180 Ohms Todas las partes de este producto incluidos los componentes el ctricos y elect nicos deben ser reciclados o...

Page 20: ...date of the Sale to the FINAL Consumer To make use of the benefits of this warranty you must present one of the following documents the Final Consumer s SALE NOTE or this completed CERTIFICATE CASES T...

Page 21: ...o retirada del n mero de serie o lote del producto 3 Mal uso del producto descuido y accidentes como agua fuego ca da instalaci n incorrecta o diferente de lo aconsejado en este manual 4 Da os o cambi...

Reviews: