![stertil-KONI ST 1082-FS Installation, Operation And Maintanance Instructions Download Page 38](http://html.mh-extra.com/html/stertil-koni/st-1082-fs/st-1082-fs_installation-operation-and-maintanance-instructions_1375431038.webp)
Operating instructions (Version F)
38
ST 1082 & ST 1100
4.
Press the <SELECT> button.
The <ALL> light will light up to indicate the following:
- the system operation has been checked to ensure its correct functioning,
- the sequence of all columns is stored in the system memory
- the master column in the system has been connected to the mains,
- the height of every column has been saved in the memory,
- the column lifts can now be operated.
5.
All system functions are now available (the default is <ALL> all columns):
- button 3 all columns will rise,
- button 4 all columns will lower in the safeguard,
- buttons 6 and 4 all columns will lower.
5.3.2 Pair operation
Note
n
Setting to the pair operation (only possible when you have an even number of
column lifts):
1.
Select the master columns at one axle to set this function (for example, the front
wheel axle).
2.
Press the <SELECT> button until the <PAIR> light starts to flash.
Next, select the other column of "the pair".
3.
Go to the other column of "the pair" and press <SELECT> until the <PAIR> light is
continuously lit. Now "the pair" has been selected.
4.
Press button 3 to raise "the pair" columns.
Press button 4 to lower "the pair" columns.
Note
n
An acoustic signal will be emitted when “PAIR” UP and DOWN is operational
because this is an exceptional situation.
Note
n
When a pair operation is set up, the other axle pairs are also automatically selected
as a pair in the operating system. This will only work correctly if all column lifts have
been configured in a closed circuit according to
Figure 4.2 "Linking columns" on
.