QUICK REFERENCE GUIDE:
CAPACITY REMAINING
MANUAL REGENERATION
NOTE: For softeners, if
brine tank does not con-
tain salt, fill with salt and
wait at least 2 hours before
regeneration. If you need to initiate a
manual regeneration, either immediately, or
the same night at the preprogrammed time for
regeneration (typically 2:00 AM), complete the following steps:
For Immediate Regeneration:
Press and hold REGEN until valve
motor starts (typically 3 seconds).
For Regeneration the same night:
Press and release REGEN
(notice that flashing "REGEN TODAY" appears.)
TO SET TIME OF DAY
In the event of a pro-
1. Accessed by
longed power outage, pressing SET CLOCK
time of day flashes, 2. Adjust hours with
indicating that this and buttons,
needs to be reset. All AM/PM toggles at 12
other information will 3. Press NEXT
be stored in memory no 4. Adjust minutes with
matter how long the and buttons
power outage. Please 5. Press NEXT to
complete the steps as complete and return to
shown to the right. To normal operation.
access this mode,
press SET CLOCK
GENERAL OPERATION
When the system is operating,
one of three displays will be
shown: Time of day, gallons of
treated water available, or
gallons per minute. Pressing
NEXT will toggle between the
three choices.
ERROR
If the display toggles between "Error"
and an error code (i.e. a number), call
a service technician and report the
error code.
BYPASS VALVE OPERATION
To shut-off water to the system, please position arrow handles as
shown in the bypass operation diagram below. If your valve
doesn't look like the diagram below, contact your service
technician for instructions on how to shut off water.
NORMAL OPERATION BYPASS OPERATION
"TREATED"
WATER EXITS
SUPPLY
WATER ENTERS
SUPPLY
WATER EXITS
SUPPLY
WATER ENTERS
ADJUST HARDNESS, DAYS BETWEEN REGENERATION,
OR TIME OF REGENERATION
For initial set-up or to 1. Accessed by pressing
make adjustments, NEXT and button
please complete simultaneously
the steps as shown to 2. Adjust hardness setting
the right. Access this and buttons
mode by pressing 3. Press NEXT
NEXT and button 4. Adjust days between
simultaneously. regenerations using
and buttons
NOTE:
Hardness display 5. Press NEXT
shows "-nA-" if used as 6. Adjust time of regen-
a filter. If other displays eration hour with
do not appear, refer to and buttons, AM/PM
manual. toggles at 12.
7. Press NEXT
8. Adjust time of regenera-
tion minutes with
and buttons.
9. Press NEXT to complete
and return to normal
operation.
12630 US Highway 33 North
Churubusco, IN 46723
Phone: (260)693-1972 Fax: (260)693-0602