Sterling Power Products
Copyright
S
TERLI G
P
OWER
Pro Batt Ultra - Battery to Battery Charger
Copyright © 2019
Sterling Power
Feb 2019 V69+
Starter
Engine Bat.
Pos
in
Pos
out
Neg
fuse
fuse
House / Domestic / Aux
/ Bow thruster
MUST READ
For the majority of users, reading this paragraph should be sufficient
for installation. The unit can be installed by simply connecting it
between an input and output battery as depicted. The unit, by default,
shall start charging when the input voltage exceeds 13.2V and
switches off when the voltage drops below 13.0V for more than 240s
(adjustable). Going above 13.2V for 5 seconds shall reset this timer.
The default charging profile is 14.4V abs. and 13.6V float -
for sealed
lead acid batteries
(x2 for 24V | x3 for 36V | x4 for 48V).
This means that
the vast amount of installations can be fitted out of the box without
any adjustments.
In certain circumstances, when installing in a Euro 6
vehicle, you may have to use an ignition feed to the unit. When the ignition
is live, unit starts charging (may take up to 60seconds). Please read the
manual for additional information. If in doubt, and installing on a New Euro
6+, use ignition feed.
Code:
BB1230
12V-12V 30A input
battery temp
sensor
USERS MANUAL.
Sterling Power Products
H Charge
Float
In / Unit
Out / Rem
Batt.
V
12.2
Temp
Menu
Change
Volts
Select
Audible alarm on/off
hold > 3 sec
On / Off
hold>3 sec
Fault
Absorption
Cond.
Optional Remote
Instructions inside
technology
4
DU
:
L
R
A
A
T
I
B
G
L
I
E
D
:
:
D
CI
E
S
M
I
A
G
N
N
Y
D
ProDigital
RoHS
compliant
R.B.F
R
egenerative
raking riendly
B
F
Test Report Sheet
Each product gets uniquely tested and a report is generated.
This unique test report is present inside this box.
You must keep this test sheet in this box and keep this box safe.
This sheet should be present when the charger is being warranted.
For other European languages refer to website:
Europe / RoW:
www.sterling-power.com
North America:
www.sterling-power.usa.com
*default mode does not require ignition feed*
Code:
BB1260 12V-12V 60A input
BB122470 12V-24V 70A input
BB123670 12V-36V 70A input
BB124870 12V-48V 70A input
BB242435 24V-24V 35A input
BB241235 24V-12V 35A input
BB123670 12V-36V 70A input
BB124870 12V-48V 70A input
+ +
+
Please read the legal and safety
information first before proceeding
and we strongly advise hiring a
professional to fit.
English Manual
WARNING: Important
For our regular customers
who fit
many of these devices. Upgrades have
taken place with this new product on
the ignition feed line.
Please note the new ignition feed cable
location has changed and link wires are
no longer required.
line to ignition
(recommended if vehicle is Euro 6)
+
+
+
Ignition
BMS (1)
BMS (2)
These instructions are for the NEWER green stripe BB models
please note that the position of the ignition feed wire has changed and also that the link wires ar no longer there