background image

Sterling Power Products

Copyright 

S

TERLI   G

P

OWER

Pro Batt Ultra - Battery to Battery Charger 

Copyright © 2019
Sterling Power 
Feb 2019 V69+

Starter

Engine Bat.

 

Pos

in

Pos

out

Neg

fuse

fuse

House / Domestic / Aux

/ Bow thruster 

 

MUST READ 

For the majority of users, reading this paragraph should be sufficient 
for  installation.  The  unit  can  be  installed  by  simply  connecting  it 
between an input and output battery as depicted. The unit, by default, 
shall  start  charging  when  the  input  voltage  exceeds  13.2V  and 
switches off when the voltage drops below 13.0V for more than 240s 
(adjustable). Going above 13.2V for 5 seconds shall reset this timer. 
The default charging profile is 14.4V abs. and 13.6V float - 

for sealed 

lead acid batteries

 

(x2 for 24V | x3 for 36V | x4 for 48V). 

This means that 

the vast amount of installations can be fitted out of the box without 
any adjustments.

 In certain circumstances, when installing in a Euro 6 

vehicle, you may have to use an ignition feed to the unit. When the ignition 
is live, unit starts charging (may take up to 60seconds). Please read the 
manual for additional information. If in doubt, and installing on a New Euro 
6+, use ignition feed.

Code:

BB1230
12V-12V 30A input

battery temp

sensor

USERS MANUAL.  

Sterling Power Products

H Charge

Float

In / Unit

Out / Rem

Batt.

V

12.2

Temp
Menu

Change

Volts

Select

Audible alarm on/off 

hold > 3 sec

On / Off

hold>3 sec

Fault

Absorption

Cond.

Optional Remote

Instructions inside 

technology

4

DU

 : 

L

R

A

A

T

I

B

G

L

I

E

 

:

:

 

 D

CI

E

S

M

I

A

G

N

N

Y

D

ProDigital 

RoHS

compliant

R.B.F

R

egenerative 

raking  riendly 

B

F

Test Report Sheet

Each product gets uniquely tested and a report is generated.
This unique test report is present inside this box.
You must keep this test sheet in this box and keep this box safe.
This sheet should be present when the charger is being warranted. 

For other European languages refer to website:

    Europe / RoW: 

www.sterling-power.com

North America: 

www.sterling-power.usa.com

*default mode does not require ignition feed*

Code:

BB1260       12V-12V 60A input
BB122470  12V-24V 70A input
BB123670  12V-36V 70A input
BB124870  12V-48V 70A input
BB242435  24V-24V 35A input
BB241235  24V-12V 35A input
BB123670  12V-36V 70A input 
BB124870  12V-48V 70A input

+ +

+

Please  read  the  legal  and  safety 
information first before proceeding 
and  we  strongly  advise  hiring  a 
professional to fit.

English Manual

WARNING: Important

For  our  regular  customers 

who  fit 

many of these devices. Upgrades have 
taken  place  with  this  new  product  on 
the ignition feed line.

Please note the new ignition feed cable 
location has changed and link wires are 
no longer required.

line to ignition

(recommended if vehicle is Euro 6)

+

+

+

Ignition
BMS (1)
BMS (2)

These instructions are for the NEWER green stripe BB models

please note that the position of the ignition feed wire has changed and also that the link wires ar no longer there 

Summary of Contents for BB1230

Page 1: ...e Float In Unit Out Rem Batt V 12 2 Temp Menu Change Volts Select Audible alarm on off hold 3 sec On Off hold 3 sec Fault Absorption Cond Optional Remote Instructions inside technology 4 DU L R A A T...

Page 2: ...ustomise Operational Voltages Detailed Installation guide Page 8 Remote Control Operations Page 13 Operational m odes 1 2 3 Comprehensive breakdow n of remote functions Installation diagram Fault Find...

Page 3: ...rrent limiting With fuses protecting the DC cables In a well ventilated dry dust free and condensation free environment When instruction manual has been read through Safety Symbols Example WARNING Nev...

Page 4: ...tage if on solid it is high output voltage if flashing it is high input voltage 10 11 13 8 9 7 6 5 4 3 12 14 15 16 17 18 23 24 19 21 17 High temp trip if flashing then high unit temperature trip 18 No...

Page 5: ...required Models BB1260 BB122470 BB123670 BB124870 BB242435 BB241235 Models BB1230 Front Panel II 8 2 3 4 7 10 11 12 13 9 5 14 5 3 4 BB122470 BB123670 BB124870 BB1260 BB242435 BB241235 4 60 73 00 4 60...

Page 6: ...signal the BBC shall start charging again Use BMS 2 if your BMS trips to a ve voltage 2V 17V then use BMS 2 This shall result in the BBC turning off when this voltage is received Once the BMS removes...

Page 7: ...2 seconds to confirm 2 x 3 sets of green LEDs shall flash to confirm Press Length s Action 0 1 Change to status fault display back to Voltage display mode 5 10 Toggles between 1 2 and 1 1 full power...

Page 8: ...24V then the unit will simply start charging If the voltage drops below 13 0V the unit shall turn off With a caveat read on However if the input voltage has exceeded 13 2V 2x for 24V for 5 seconds the...

Page 9: ...old both buttons for 30 seconds and let go The LED columns shall alternatively flash To confirm factory default press BOTH buttons again for 2 seconds Once confirmed 3 green LEDs on both columns shall...

Page 10: ...auto regen timer starts to count If the voltage does not rise above 13 2V the timer will not reset and the unit will switch off however as soon as the voltage rises above 13 2V the auto regen timer w...

Page 11: ...red custom values make a note Boost bulk absorption V ________ Conditioning V ________ Float V ________ AbsorptionTime Factor 0 18 ________ Absorption Minimum 0 960 minutes ________ Absorption Maximum...

Page 12: ...ck mode constant voltage full current accessibility Stage 4 Backlash voltage If charger power exceeded and battery discharge unit resets to stage 1 Stage 5 Time Depending on battery size type state of...

Page 13: ...e display shall read loc on number you have stored To remove loc return to loc and re enter the number Press select button and the display should read loc off green back light Please make a note of th...

Page 14: ...ltage is 0 13V starter battery voltage then alternator may have failed Or requires increase rpm of engine possible belt slip Is your output voltage slightly higher or lower than expected even with no...

Page 15: ...does not apply for shipping organised by yourself Please do not throw out any shipping or packaging materials All returns for any reason will require a proof of purchase with the purchase date The pr...