SVEM*
Stationary Vehicle Engage Mode
Pro Batt Ultra starts charging when input is >13.1V.
Turns off when input is <13.0V.
OEM lock - press Setup button for 30+ seconds -
4 x red LEDs should light to confirm.
repeat procedure to remove the lock.
This mode prevents operators tampering with the unit’s
settings when in the field. The OEM / fitter can set the
unit up as they desire first, the settings shall be stored,
then they can apply this lock.
Guide to buttons
Press Length (s)
Action
2-5
Forces unit into float mode. Press again to take out of float mode.
5-10
Turns unit on / off toggle.
10-20
Battery type select - use SETUP / SELECT to toggle between types. Both to confirm.
20-30
Change operational on/off voltages - use both buttons to scroll between voltages.
30+
Reset unit to default. Then press and hold both buttons for 2 seconds to confirm.
2 x 3 sets of green LEDs shall flash to confirm.
Press Length (s)
Action
0-1
Change to status fault display / back to Voltage display mode.
5-10
Toggles between 1/2 and 1/1 (full) power.
10-15
Set Auto Regen. time - use either buttons to toggle between the preferred time.
15-30
Live output voltage (power supply mode) - press SELECT to change to LED 24.
30+
OEM lock
- disables further adjustment of unit’s functions.
40+
Puts the unit into PURE IGNITION MODE - unit ONLY works with a live ignition.
ideal if you do not want BB charging at all when engine is off. Software V69+
Press Length (s)
Action
2-5
Night mode = 1/2 power for 8 hours, then back to full power.
5-10
Enter standby mode. To take out of standby, repeat.
10-15
Display software version (displayed in binary on display).
15+
SVEM
- Stationary Vehicle Engage Mode
40+
Turns off alarm buzzer indefinitely. Repeat procedure to reapply alarm buzzer.
7
If BB is in sleep mode, either buttons can be pressed to wake the BB up.
New
software V69+
New
software V69+