Sterling Power Products
Copyright
10
11
13
8
9
7
6
5
4
3
2
1
12
14
15
High bat temp (fl) SVEM (S)
Regen timer off (S) / on (fl)
16
17
18
19
20
21
22
23
24
25
26
27
28
Front label display
1 & 26)
ENTER / SETUP and SELECT buttons, used to
adjust settings.
2 & 25)
Background light for button, used also to show
unit is operational.
3)-11)
The left column of LEDs have 3 different
functions. Firstly, on unit start up the battery type is
displayed. Secondly, after startup it becomes an input
voltmeter. Thirdly, during custom setting the voltage
scale is used to set the voltage - refer to later.
12)
This LED has 3 meanings. Firstly, when on battery
type selection mode this is the LiFePO
4
lithium battery
indicator. Secondly, on default mode (most times) this
shows the charger is on fast charge mode. Thirdly, if
flashing, then the unit is in standby and was in fast
charge prior to entering standby.
13-15)
These LEDs show the battery charge
progression through its cycle.
15)
Flash when in standby.
16-24)
Has 3 functions: Firstly, during operation they
show the output voltage. Secondly, if an alarm is present
the alarm shows up. Thirdly, this row is used in the
custom setup procedure to set timing functions, voltages
and time factors. Its general function is as an output
voltmeter, in the event 2 LEDs are on the voltages is
between the 2 settings, if the top or bottom red LED is on
then the voltage is outside the parameters off the
voltmeter.
16)
High voltage, if on solid it is high output voltage, if
flashing it is high input voltage.
10
11
13
8
9
7
6
5
4
3
12
14
15
16
17
18
23
24
19
21
17)
High temp trip, if flashing then high unit
temperature trip.
18)
No faults (solid on). Power Pack mode / live
voltage output (flashing).
19)
No regen. mode or regen. timer at 0 = solid LED.
Regen on / timer on = flashing LED.
20)
Remote Battery sense cable connected (solid).
Battery sense voltage drop in cable outside the
21)
prescribed 1.5V drop maximum, thicker cable
required - LED flashing.
22)
Device’s power ability reduced due to high
ambient temperature or voltage drop in output cable
to big. Alarm will be in conjunction with other
information alarm. If flashing unit is in night mode
with reduced power and low fan speed.
23)
Low voltage alarm, low voltage on input =
flashing LED. Input alternator not supplying enough
power or failed. Low voltage output = solid LED.
Something consuming a lot of power or unit not
working. No voltage output then LED on solid.
24)
If flashing then battery temperature too high.
Solid LED is in
SVEM mode - Stationary Vehicle
Engage Mode.
27)
Numbers relating to battery custom setup (if
used) this is the charge factor number.
28)
Numbers relating to custom setup mode these
numbers relate to timing, i.e. maximum and
minimum time settings.
20
22
Models:
BB1260 / BB122470 / BB123670 / BB124870 /
BB242435 / BB241235 / BB123670 / BB124870
Model:
BB1230
Front Panel
Regen timer off (S) / on (fl)
High bat temp (fl) SVEM (S)
4
Remote control
Battery
temperature
sensor
Rem V sense
SETUP
ENTER
SELECT
Reverse
polarity
tell
Enter/Select
buttons under cover
Reverse
polarity
tell
f u s e
Bat
in +
Bat
out +
Neg
-
1 26
Ignition
BMS (1)
BMS (2)
1