13. Display of the diagnoses
Message Diagnosis
Possible causes
Solutions
A01
No electrode
conductivity.
Electrode not or
incorrectly connected.
Check the connection on the box
and electrode ends. Re-tighten
the nuts if necessary.
This message is SELF-RESETTING when the solution is applied.
A01
Message Diagnosis
Possible causes
Solutions
A15
Electrode
condition.
Salt level too high.
Check the max. salt content
5 g/litre.
Scaled electrode.
Check the electrode condition
/ Clean with a suitable product
(Acidulor) if necessary.
Electrode short
circuited.
Check the connection and the
electrode condition.
A16
Electrode
condition.
Salt level too low.
Check the min. salt content
4 g/litre.
Scaled electrode.
Check the electrode condition
/ Clean with a suitable product
(Acidulor) if necessary.
Electrode wear.
The electrode is at the end of its
service life. Replace it.
A17
Electrode condition
Salt level too low.
Check the min. salt content
4 g/litre.
Electrode disconnected. Check the electrode connection
and the continuity of its cable.
Scaled electrode.
Check the electrode condition
/ Clean with a suitable product
(Acidulor) if necessary.
Electrode out of order.
The electrode is at the end of its
service life. Replace it.
The electrode condition is checked every 100 hours of operation.
These messages do not stop the appliance from operating, chlorine
production continues.
These messages can be RESET by briefly pressing keys + and -.
A15
A16
A17