background image

About us

Steridose is a global company and our world head-

quarters are located in Tumba, Sweden. We are highly
specialized in the design, development and manufactur-
ing of magnetic coupled mixers and radial diaphragm
valves.

Steridose is part of the Velcora group, with regional

offices in key locations around the world.

Steridose is represented in important certifying and

standards organizations, most notably and relevant to
the pharmaceutical industry, ASME BioProcessing Equip-
ment standards committee (BPE). We help develop the
standards and Good Manufacturing Practices that mini-
mize risk for process interference.

Steridose partners with the best distributors and repre-

sentatives in the industry all over the world. Together we
become the perfect mix; a premium product with global
references combined with local presence for product and
application support.

Steridose AB

Himmelsbodavägen 7
SE 147 39 Tumba, Sweden
Phone: +46 8 449 9900
[email protected]

www.steridose.com

Steridose Inc.

5020 World Dairy Drive
Madison, WI 53718, U.S.A.
Phone: +1 608 229 5225
[email protected]

www.steridose.com

Visit our website for the latest version of this document. The original instruction is in English, all non-English

instructions are translations of the original instruction. © Steridose AB

STD0023EN00

Revision

en-1.0.0

-

20180831

Summary of Contents for sterimixer

Page 1: ...anual for future reference 1 2 Safety terminology and symbols 1 2 1 Hazard levels and indications The following symbols are used to indicate hazard levels DANGER Indicates a hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a hazardous situation which...

Page 2: ...ngers Pay attention to the risks of electric shock or arc flash hazards Always bear in mind the risk of pinching fingers electrical accidents and burn injuries 1 4 2 Safety equipment Use safety equipment according to the company and local regulations 1 4 3 Electrical connections Electrical connections must be made by certified electri cians in compliance with all international national state and l...

Page 3: ...12837 210 112838 a includes extended drive unit flange extended shaft and lowering device b includes lowering device assumes re using shaft and flange n Table 1 Part numbers for upgrade kits Refer to sec tion 7 for details for the magnet rotor when in the lowered position the use of the Magnet Lowering Device requires the drive unit to be equipped with the cooling jacket extension Retrofit kits ar...

Page 4: ...n Figure 2 Example of a sign for the correct use of the Magnet Lowering Device 4 Steridose www steridose com ...

Page 5: ...gearbox 3 Remove the shaft from the gearbox s hollow shaft 4 Remove the magnet rotor from the shaft STRONG MAGNETIC FIELDS HAZARD The Sterimixer impeller and magnetic rotor include strong magnets with the associated risk of pinching fingers and permanently damaging magnetic cards e g credit cards if being close to these compo nents HAZARD FOR WEARERS OF CARDIAC PACE MAKER The Sterimixer impeller a...

Page 6: ... stop provided by the bottom circlip If necessary use a file to de burr and straighten the hollow shaft keyway and or the bot tom shaft key 12 Once the shaft runs smoothly up and down the gear box apply additional grease to the gearbox s hollow shaft 13 Apply a suitable thread sealant locking liquid e g Loctite 243 Loctite 2400 to the Magnet Lowering Device screw 14 Screw the Magnet Lowering Devic...

Page 7: ...t cards if being close to these compo nents HAZARD FOR WEARERS OF CARDIAC PACE MAKER The Sterimixer impeller and magnetic rotor include strong magnets thus personnel equipped with pacemaker shall not handle these components Fix the magnet rotor on the shaft with the magnet rotor screw 18 For final tightening of the magnet rotor and Magnet Lowering Device mounting screw put the drive unit on its si...

Page 8: ...he sensor works as intended Since the magnetic sensing range might pick up interference from other moving parts in the Magnet Lowering Device the sensor bracket has a slotted hole to allow for adjustment of the sensor position to eliminate interference Sensor technical data can be obtained from the sensor supplier s product information 8 Steridose www steridose com ...

Page 9: ...www steridose com Installation Operation 9 ...

Page 10: ...ing Practices that mini mize risk for process interference Steridose partners with the best distributors and repre sentatives in the industry all over the world Together we become the perfect mix a premium product with global references combined with local presence for product and application support Steridose AB Himmelsbodavägen 7 SE 147 39 Tumba Sweden Phone 46 8 449 9900 info steridose com www ...