Upgrade kit contents: 1. extended drive unit

flange, 2. extended shaft, 3 mounting tool, 4. the lowering
device.

DU LD KIT:

This kit is intended to be used when up-

grading drive units delivered in or after 2018. Since
the standard drive unit with cooling extension deliv-
ered in or after 2018 are already equipped with the
modified drive unit flange and shafts with bottom
thread (please consult factory), this kit only contains
the mounting tool and the lowering device (items 3
and 4 in figure 3).

+

NOTICE:

Due to international shipping regulations

grease required for successful retrofit of the lowering
device is NOT included in the kits.

7.1. Steps for assembling the Magnet Lowering Device.

1. Clean the drive unit and especially the gearbox thor-

oughly.

2. Remove the drive unit flange from the gearbox by

loosening the screws that fix it to the gearbox.

3. Remove the shaft from the gearbox’s hollow-shaft.

4. Remove the magnet rotor from the shaft.

STRONG MAGNETIC FIELDS HAZARD:

The

Sterimixer impeller and magnetic rotor include
strong magnets with the associated risk of pinching
fingers and permanently damaging magnetic cards

(e.g. credit cards) if being close to these compo-

nents.

HAZARD FOR WEARERS OF CARDIAC PACE-
MAKER:

The Sterimixer impeller and magnetic

rotor include strong magnets thus personnel
equipped with pacemaker shall not handle these
components.

5. Check the gearbox mounting frame for damage and

remove any paint, leaving the surface of interface
between flange and gearbox clean, even and smooth.

6. Apply a suitable grease (e.g. Chesterton 630 SXCF)

to the gearbox’s hollow-shaft and the frame interface.

This will facilitate movement of the shaft and protect

against corrosion.

7. Fit the extended drive unit flange to the gearbox and

tighten the screws.

8. Fit the bottom circlip on the shaft (use protective eye-

wear when fitting circlips).

www.steridose.com

Installation & Operation

|

5

Summary of Contents for sterimixer

Page 1: ...anual for future reference 1 2 Safety terminology and symbols 1 2 1 Hazard levels and indications The following symbols are used to indicate hazard levels DANGER Indicates a hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a hazardous situation which...

Page 2: ...ngers Pay attention to the risks of electric shock or arc flash hazards Always bear in mind the risk of pinching fingers electrical accidents and burn injuries 1 4 2 Safety equipment Use safety equipment according to the company and local regulations 1 4 3 Electrical connections Electrical connections must be made by certified electri cians in compliance with all international national state and l...

Page 3: ...12837 210 112838 a includes extended drive unit flange extended shaft and lowering device b includes lowering device assumes re using shaft and flange n Table 1 Part numbers for upgrade kits Refer to sec tion 7 for details for the magnet rotor when in the lowered position the use of the Magnet Lowering Device requires the drive unit to be equipped with the cooling jacket extension Retrofit kits ar...

Page 4: ...n Figure 2 Example of a sign for the correct use of the Magnet Lowering Device 4 Steridose www steridose com ...

Page 5: ...gearbox 3 Remove the shaft from the gearbox s hollow shaft 4 Remove the magnet rotor from the shaft STRONG MAGNETIC FIELDS HAZARD The Sterimixer impeller and magnetic rotor include strong magnets with the associated risk of pinching fingers and permanently damaging magnetic cards e g credit cards if being close to these compo nents HAZARD FOR WEARERS OF CARDIAC PACE MAKER The Sterimixer impeller a...

Page 6: ... stop provided by the bottom circlip If necessary use a file to de burr and straighten the hollow shaft keyway and or the bot tom shaft key 12 Once the shaft runs smoothly up and down the gear box apply additional grease to the gearbox s hollow shaft 13 Apply a suitable thread sealant locking liquid e g Loctite 243 Loctite 2400 to the Magnet Lowering Device screw 14 Screw the Magnet Lowering Devic...

Page 7: ...t cards if being close to these compo nents HAZARD FOR WEARERS OF CARDIAC PACE MAKER The Sterimixer impeller and magnetic rotor include strong magnets thus personnel equipped with pacemaker shall not handle these components Fix the magnet rotor on the shaft with the magnet rotor screw 18 For final tightening of the magnet rotor and Magnet Lowering Device mounting screw put the drive unit on its si...

Page 8: ...he sensor works as intended Since the magnetic sensing range might pick up interference from other moving parts in the Magnet Lowering Device the sensor bracket has a slotted hole to allow for adjustment of the sensor position to eliminate interference Sensor technical data can be obtained from the sensor supplier s product information 8 Steridose www steridose com ...

Page 9: ...www steridose com Installation Operation 9 ...

Page 10: ...ing Practices that mini mize risk for process interference Steridose partners with the best distributors and repre sentatives in the industry all over the world Together we become the perfect mix a premium product with global references combined with local presence for product and application support Steridose AB Himmelsbodavägen 7 SE 147 39 Tumba Sweden Phone 46 8 449 9900 info steridose com www ...

Reviews: