Instruction Manual of
-S3 Inverter for Elevator
Table 5.5 U parameters of operation status, continued
Function
code
Name
Explanation
Range
Unit
Default
value
Remarks
输入
DI1-DI12
U11
Input DI1- DI12
Monitor of input status of DI1-
DI12, in “XXXXXXXXXXXX”,
where “X” = 0, indicating no
input, while “X” = 1, indicating
input.
× × ×
Combined with function
codes of F parameters.
输出
DO1-DO6
U12
Monitor of input status of DO1-
DO6, in “XXXXXX”, where “X”
= 0, indicating no output, while
“X” = 1, indicating output.
× × ×
Combined with function
codes of G parameters.
Output
DO1-DO6
输出电压相位
Monitor of output voltage phase
(for synchronous motors only)
× Deg.
×
U13
Output voltage
phase
输出电流相位
Monitor of output current phase
(for synchronous motors only)
× Deg.
×
U14
Output current
phase
r
Di
git
al O
pera
to
散热器温度
U15
Radiator
temp.
Monitor of radiator temperature
×
℃
×
Under
【
Run State
】
mode, the first line of the LCD shows the “Run State”, the second line
the function code and its parameter value, and the third line the name of the parameter, as
shown in the
following figure.
Select the parameter to be displayed through “Increment” or “Decrement” key, as shown
in the following figure.
5-
5