Instruction Manual of
-S3 Inverter for Elevator
B-
1
List
s of
Function Parameters
, Runnin
g
-st
atus and Fault
s
Appendix B Lists of Function Parameters, Running
Status and Faults
This appendix is a collection of the function parameter list, running status list and fault list for
the convenience of reference and application of the Inverter.
B.1 Function Parameter
Function
Code
Name
Content
Range
Unit
Default
Remarks
A
Advanced
Menu
Display of the version of the digital operator, language selection, motor autotuning and
mode selection (R/W).
固件版本
A01
Firmware
Version
Inverter version.
Set the following value and press
Enter:
99.99: to reset all parameters to
default value;
99.98: to clear all fault records;
88.88: no checking
Inverter fan:
88.89: to check Inverter fan.
Press ENTER to return to Inverter
version.
Refer to Note 1.
0
~
655.35
× 445.01
语言选择
A02
Language
Select
Select the display language of the
operator:
0: English;
1: Chinese.
0 / 1
×
1
同步电机
自整定
A03
PMSM
AutoTunning
Autotuning for synchronous
motors:
0: normal operation;
3: completion of motor autotuning
(A03 automatically changed to
“
3
”
after each autotuning
process);
4: go to autotuning mode;
7: save encoder identification data
for SIN/COS encoders;
9: go to SIN/COS encoder
identification;
10: encoder identification status
(A03 automatically changed to
0/4/7/9 × 0