Instruction Manual of
-S3 Inverter for Elevator
Table 2.4 Technical indexes and specifications of
400V
-S3
Inverter
Model Number:
-S3
4002 4003 4005
4007
4011
4015
4018
4022
4030 4037
4045 4055
4075
Maximum Applicable Motor
Output (kW)
2.2 3.7 5.5
7.5
11 15 18.5
22 30 37
45 55 75
Rated capacity
(kVA)
4.7 6.9 8.5
14 18 24 29 34 50 61
74 98 130
Model and S
pecification
Rated
current
(A) 6.2 9 13 18 27 34 41 48 65 80
97 128
165
Rated
Output
Maximum voltage
output (V)
3-phase, 380/400/415/440/460 (corresponding to voltage input)
Phase, voltage,
frequency
3-phase, 380/400/415/440/460V 50/60Hz
Allowed fluctuation
in voltage
-15%
~
+10%
Allowed fluctuation
in frequency
-5%
~
+5%
3-phase unbalance
rate
≤
2%
Power
Supply
Instantaneous low
voltage bearing
Keep running above AC 300V;
Undervoltage protection occurs when the voltage is below AC 300V and lasts for 15 ms.
Table 2.5 Shared technical indexes and specifications of
200V
and
400V
-S3
Inverters
Control method
Vector control with PG card
Startup torque
150% 0Hz (vector control with PG card)
Speed range
1:1000 (vector control with PG card)
Speed precision
±0.05% (vector control with PG card, 25±10 )
℃
Torque limit
Yes (set by parameter)
Torque precision
±5%
Frequency control range
0
~
100Hz
Frequency precision (temp.
fluctuation)
±0.01% (digital instruction)
,
±0.1% (analog instruction)
Frequency setting resolution
0.01Hz (digital instruction)
,
±0.03Hz/60Hz (analog instruction)
Control
Characteristics
Frequency output resolution
(calculation of resolution)
0.001Hz
Zero speed to 130%, <3Hz when 150%,> 3Hz 185% when
Overload ability
Braking torque
150% (connecting peripheral braking resistor), built-in braking
unit
Accelerating/decelerating time
0.01
~
3600s
Carrier frequency
5
~
15kHz
2-
3