Connecting the Water Supply
1. The machine should be situated within 1 metre of a drinking water supply from a
rising main, terminating with a W.R.C. approved 15mm compression stop tap.
2. The water supply should comply with both the Statutory Instrument No.1147 -
“Water, England and Wales” and The Water Supply (Water Quality) Regulations
1989.Water pressure at the stop tap must be within the limits 1 - 8 Bar (100 Kpa - 800
Kpa).
3. Connect the flexi-hose supplied with the machine to the stop tap ensuring that the seal
supplied is fitted correctly. Flush the system via the stop tap (several gallons) before
connecting the hose to the machine.
4. Connect the hose to the inlet valve located on the rear of the machine. Ensure that the
seal is correctly fitted. Ensure that all water supply fittings are tight.Turn on the stop tap
and check for leaks.
Connecting the Electricity Supply
Safety First! THE MACHINE MUST BE EARTHED. ON NO ACCOUNT
SHOULD IT BE EARTHED TO THE WATER SUPPLY PIPE
The machine must be connected to a 240 Volt 50Hz 13 amp fused switched socket
outlet, installed to the latest edition of the IEE regulations, using a 3 pin BS approved
13 amp fused plug.
Important: If the mains lead becomes damaged in any way it must be replaced by a
special lead available from the manufacturer.