7 TECHNICAL 

SPECIFICATIONS 

System Pro700 

Number of stations 

Max 

40  

 

recommended 

16 - 20  

Extension call numbers   

 

10-49  

Conversation channels 

 

1  

Program distribution channels 

1  

Input to program channel 

aux. line 

100 mV / 600 ohm  

Power supply 

 

18 VDC (12–27)  

Line specification 

3 twisted pairs 

0.5 or 0.6 mm

Ø

  

Max. distance between power supply and a station,  
0.6 mm

Ø

 cable 

12 VDC 

100 m (330 ft)  

 

18 VDC 

300 m (1000 ft)  

 

24 VDC 

500 m (1600 ft) 

Total cable capacitance 

max. 

87 nF 

Max. cable run in a system

 

Standard cable quality 

120 nF/km 

700 m (2100 ft) 

Good cable quality 

47 nF/km 

1700 m (5100 ft) 

 

Common Station Data 

Operating voltage           

 

12 - 27 VDC 

Current drain 

idle 

30 mA  

 

max 

200 mA  

Frequency range 

 

100 - 5000 Hz  

Output power 

internal loudspeaker 

1 W  

Volume control range 

 

23 dB 

Type of signaling 

 

32 kHz ASK  

 

Master Station - AA711 

Type 

Gray ABS 

Desk / Wall 

Wall mounting 

Bracket 

GF732 

Dimensions: 

D x W x H 

64 x 78 x 214 mm 

  

 

2.5 x 3.0 x 8.4 inch 

 Weight  

 

215 g 

Output power 

external 20 ohm loudspeaker 

2 W 

Current drain 

w/ external loudspeaker  

400 mA 

Display LCD 

digits 

Remote Output (relay) 

resistant load 

max. 48 V/1 A 

 

Master Stations - AA702, AB708, AB709

 

Type Gray 

ABS 

Wall 

Dimensions 

D x W x H 

51 x 80 x 220 mm 

  

  

2.0 x 3.1 x 8.7 inch 

Weight  

350 

Output power 

external 20 ohm loudspeaker 

2 W  

Current drain 

w/ external loudspeaker  

400 mA 

 

Display 

AA702 

LCD, 8 digits 

 

 

 

CE Certification

 

All Pro700 equipment are tested and comply with the EMC 
(Electromagnetic Compatibility) directive 89/336-EEC of the 
European Community and meet or exceed the following 
standards:  
EN 50081-1 Emission 
EN 50082-1 Immunity

Industrial Master Stations 
AA703, AA704, AA705, BC735 

AA703

 

Type  

Gray Bayblend / Dark grey foil 

Wall 

Dimensions 

D x W x H 

63 x 124 x 244 mm 

 

 

2.5 x 4.9 x 9.5 inch 

Weight  

845 

AA704

 

Type 

Dark grey PVC 

Flush / wall w. box 

Dimensions 

D x W x H 

50 x 125 x 280 mm 

 

 

2.0 x 4.8 x 11 inch 

Weight  

400 

AA705

 

Type Orange 

Macrolon Wall 

Dimensions 

D x W x H 

137 x 160 x 240 mm 

 

 

5.4 x 6.3 x 9.4 inch 

Weight  

1000 

BC735

 

Type 

Gray Bayblend / Dark grey foil 

Wall 

Dimensions 

D x W x H 

63 x 124 x 244 mm 

 

 

2.5 x 4.9 x 9.5 inch 

Weight  

750 

Common

 

Current drain 

w/ external loudspeaker 

500 mA 

Output power 

external 20 ohm loudspeaker 

3 W  

Remote Output (relay)  resistant load 

5 A 

 

Door- / Tamper Resistant Stations 
AB731, AB731-F, AB731A, AB731A-F 

AB731 / AB731A

 

Type 

Aluminum box, steel front 

Wall 

Dimensions 

D x W x H 

65 x 90 x 180 mm 

 

 

2.6 x 3.5 x 7.1 inch 

Weight  

1500 

 

AB731-F / AB731A-F

 

Type Steel 

front 

Flush 

Dimensions 

D x W x H 

60 x 130 x 220 mm 

 

 

2.4 x 5.1 x 8.7 inch 

Weight  

900 

Common AB731 stations 

Current drain 

w/ external loudspeaker 

500 mA 

Output power 

external 20 ohm loudspeaker 

3 W 

Local Output (lamp) 

max. load 

300 mA 

Remote Output (relay)  resistant load 

5 A 

 

Clean room station - AA706 

Type 

Polyester film w/ antimicrobial front 

 

Flush mount in back box 

Dimensions 

D x W x H 

50 x 125 x 280 mm 

 

 

2.0 x 4.8 x 11.0 inch 

Weight  

1200 

Protection Front 

access 

IP65 

Current drain 

w/ external loudspeaker 

500 mA 

Output power 

external 20 ohm loudspeaker 

3 W 

Local Output (lamp) 

max. load 

300 mA 

Remote Output (relay)  resistant load 

5 A

 

Summary of Contents for Pro700

Page 1: ...1 Pro700 Installation and Programming Manual A100K10226 v 4 1 Jul 2006 Pro700 Communication System Installation and Programming TECHNICAL MANUAL A100K10226 v 4 1 2006 06 06 ...

Page 2: ...ultipurpose substation 10 2 4 Optional Equipment and Interface Units 10 GD745 Handset module 10 GH750 Multipurpose Relay Unit 10 HD752 Audio PA and Radio Interface 11 HD754 Telephone Interface 11 FC740 10 Watt Amplifier w talk back 11 DP996 Sound Detection Module 11 LA617 LA618 and LA925 Power Supplies 12 BD702 Station Kit 12 2 5 Accessories 12 GF732 Wall bracket 12 BF636 Front plate frame 12 Back...

Page 3: ...ual is based upon stations with REV C These stations have Software Edition HM2 For older versions of stations please use the Guide A100K10226 02 00 Aug 1998 or 03 00 Jan 2002 Old and new versions of stations will work together with all functions they can be programmed to perform It is important to note that if the feature SILENT ALARM is to be used on the system all stations must have the new soft...

Page 4: ...ormance on the market 1 1 Typical Pro700 System Users z Small industries z Small prisons z Police stations z Warehouses z Shops supermarkets z Petrol Gas stations z Doctor offices z Dentist offices z Workshops z Nursing homes z Door and gate control z Schools z Private homes Program distribution 12 27V Telephone interface Public address relay unit Closed radio network Master stations Substations M...

Page 5: ... stations access to a busy line 0 Microphone cutout 0 Hurry up 0 Call last caller System Features Loud speaking hands free Soft speaking confidential Privacy Microphone cut out Manual control of speech direction simplex Camp on busy queue feature Call back Hurry up Absence registration Display information Call reply Last number redial Call to last caller Emergency call All call with reply Two Grou...

Page 6: ...nected to the station s wall socket z Programmable features and extension numbers z 8 digit LCD display show caller identification and message absence information z A built in relay can be used for remote output door lock control or to drive external call indication z Designed for desk use or wall mounting using wall bracket GF732 z Connected to an RJ45 wall socket with flexible station cord z Hig...

Page 7: ... Keyboard foil of UV cured PVC resistant to numerous fluids and chemicals z The keyboard is equipped with an adjustable backlight z Internal 3 Watt amplifier z Speaker volume is adjustable with switches inside the station z The unit is prepared for connection of an external speaker z The 10 Watt power amplifier FC740 can be used with this station z A built in relay can be used for Remote Output Do...

Page 8: ...o all programmed stations direct dial to station no 13 emergency call to all stations z Internal 1 Watt amplifier z The speaker volume can be adjusted inside the station z External loudspeaker can be connected to the station s terminals z Designed for wall surface mounting with BF 636 frame z High grade impact resistant ABS plastic with a satin finish AB709 Wall Substation with 3 direct dialing bu...

Page 9: ...ilt in relays for Remote Output or Door Opener function z Optional Sound Detection Module DP996 can initiate a call when a preset sound level is reached AB731A AB731A F Door station substation z Robust vandal proof and dust resistant designed for in or outdoor use AB731A on wall mounting AB731A F flush mounting z Aluminum construction with 1 5 mm stainless steel front plate for optimal protection ...

Page 10: ...on or to drive external call indicators z Handset GD745 can be connected to the unit 2 4 Optional Equipment and Interface Units GD745 Handset module z The GD745 Handset Module can be connected to the following Pro700 stations AA703 AA704 AA705 BC735 z Equipped with a cradle switch and a press to talk button for simplex function GH750 Multipurpose Relay Unit z Equipped with 8 programmable relays z ...

Page 11: ...z Incoming calls One preprogrammed number in the Pro700 system call no 13 or the door bell function Selective dialing any number in the Pro700 system z A programming option is to give a 4 digit password code to incoming calls before access is given to the Pro700 system z The telephone conversation may be loud speaking and hands free in the Pro700 system FC740 10 Watt Amplifier w talk back z 10W am...

Page 12: ...chanical parts such as housing front plate button s and keyboard must be supplied locally Detailed assembling diagrams are included 2 5 Accessories GF732 Wall bracket Gray plastic bracket for wall mounting of station AA711 BF636 Front plate frame Plastic frame for flush mounting of stations AA702 AB708 and AB709 Back boxes BF934 Metal box for flush mounting AB731 F and AB731A F BF935 Metal box for...

Page 13: ...tations The output is adjustable between 13 5 and 18V LA925 27VDC 5A units should be used in systems with long cable runs and max 25 stations z Maximum distance on a 0 6 mmØ 24 AWG wire between any station and a power unit is 12 V 100 meters 300 ft 18 V 300 meters 1000 ft 24 V 500 meters 1600 ft z A system can be powered with more than one unit to give a decentralized solution for large installati...

Page 14: ...Loop configuration z The stations are connected in parallel along one cable run z The system power should be connected where the majority of stations are located 3 1 6 Considerations Power supply z The power supply must be wall mounted and located in an area with adequate ventilation z The temperature must be between 0 35o C 32 95o F z The relative humidity range of 30 to 90 must be maintained Ins...

Page 15: ...tation to receive All Call and Group Calls in group 1 and or group 2 4 5 Applications and Features Locate the10 switch U3 switch package 4 5 1 Station type The U3 switches 1 2 and 3 are used to set the station type z Master stations Substations Standard station Direct Dial 1 and 3 key station Direct dial 10 key station Doorbell station CAS Operator station CAS Call in station 4 5 2 Station feature...

Page 16: ...larm Yes No SW FUNCTION ON OFF 4 5 6 7 8 9 10 CAS OPERATOR STATION Call time 30 sec Doorbell no on key 6 2 1 Doorbell tone on key 6 5 sec Single 2 1 Doorbell active time 30 sec 2 min SW FUNCTION ON OFF 4 5 6 7 8 9 10 Doorbell no on key 9 Doorbell tone on key 9 5 sec Single DOORBELL STATION DIRECT DIAL 10 KEY STATION Call time 30 sec Always Privacy Yes No Emergency Call on key 9 Yes No Dir Dial Num...

Page 17: ...ith its power supply to terminals 1 and 8 Door opening activated by 5 from a priority station during conversation Set jumper E pos 1 2 Optional Warning active when station is called cancelled by 2 Set jumper E pos 2 3 External call switch Program distribution can be substituted by an external switch in parallel with the keyboard switch 6 or 9 Connect the switch between terminals 2 and 6 Remove jum...

Page 18: ...s TB1 5 and 6 The loudspeaker can be connected independent of jumper settings and other equipment Remote Output The built in relay can carry max 5 A Door opening activated by 5 from a priority station during conversation Set jumper 1 to pos 2 3 Connect the door magnet in series with its power supply to terminals TB1 9 and 10 Optional Warning active when station is called cancelled by 2 Set jumper ...

Page 19: ...be opened to get access to the terminal blocks External loudspeaker Connect a 20 50 ohm loudspeaker to terminals TB1 5 and 6 The loudspeaker can be connected independent of other equipment Remote Output The built in relay can carry max 5 A Door opening activated by 5 from a priority station during conversation Connect the door magnet in series with its power supply to terminals TB1 9 and 10 Remote...

Page 20: ...he CAS feature is programmed in each station CAS calls are in simplex normal calls are in duplex CAS functions in display First call in queue Queue index no Number of calls in queue Features Idle station Accept CAS call 0 Scroll queue T Move call to last in queue X Remote dial connect station A to B 94 A B Audio monitoring automatic one round 95 5 Audio monitoring manually one round 95 6 Audio mon...

Page 21: ...ram the audio level in four levels 5 7 Sound Detection Module DP996 DP996 can be mounted inside all stations in the AB731 series Open the station and replace the 3 nuts on NFE1825 with the 3 supplied spacers Press NFE1821 into the 7 pin header P2 of NFE1825A Fasten NFE1821 with the 3 nuts See separate documentation for programming of the DP996 module 5 8 Wiring Diagram all stations 1 2 ON OFF SW1 ...

Page 22: ...make a call to no 10 by pressing the call button The call queue is indicated in the display of no 10 The calls are accepted one by one by pressing 0 z Station no 10 can dial to all cell stations z Stations no 31 32 and 33 can receive All call messages from no 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6...

Page 23: ...ll button The call queue is indicated in the display of no 10 11 and 12 The calls are accepted one by one by pressing 0 in any of the guard stations z All guard stations can call each other and all substations 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1...

Page 24: ...io for conversation z In the radio the S is start duplex operation closed during the whole conversation if required by the radio set z The T is Talk in simplex operation closed when press to talk button T is used in the calling station 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1...

Page 25: ... 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 8 1 8 1 8 1 8 1 8 AA711 AA711 AA711 AA711 AA711 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 POWER U2 U2 U3 U3 No 10 No 11 No 21 No 20 No 22 Direc t dial 10 key Direc t dial 10 key Direc t dial 10 key Direc t dial 10 key Direc t dial 10 key CASHIER 2 CASHIER 1 ...

Page 26: ...0 11 12 and 13 in group 1 by dialing 91 to stations no 12 and 13 in group 2 by dialing 92 z Station no 10 11 12 and 13 can listen to music by selecting 96 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 8 AA702 AA705 AA703 AB731A AA711 ...

Page 27: ... with the EMC Electromagnetic Compatibility directive 89 336 EEC of the European Community and meet or exceed the following standards EN 50081 1 Emission EN 50082 1 Immunity Industrial Master Stations AA703 AA704 AA705 BC735 AA703 Type Gray Bayblend Dark grey foil Wall Dimensions D x W x H 63 x 124 x 244 mm 2 5 x 4 9 x 9 5 inch Weight 845 g AA704 Type Dark grey PVC Flush wall w box Dimensions D x ...

Page 28: ...for the user The station range is tuned to most user segments and environmental conditions with master stations for office shop and industrial use and substations designed for e g door control lifts small prisons and parking garages Stations support external loudspeakers for increased sound power or 10 W power amplifiers for PA and interface to e g remote door opening warning lights telephone remo...

Reviews: