11
Pro700
Installation and Programming Manual
A100K10226 v.4.1 Jul. 2006
HD752
Audio, PA and Radio Interface
z
General interface for connection of various external audio sources
to the Pro700 system
-
public address
-
closed radio networks
-
alarm systems and more.
z
The unit has one input (RX) for receiving and one for transmitting
(TX) audio signals.
z
Built-in relays control the KEY and ON functions.
z
All Call can be activated by an external closing contact and use an
external audio source as input.
HD754
Telephone Interface
z
Analogue interface unit to interconnect a Pro700 system with a
public telephone line or PABX.
z
The unit permits calling in both directions
z
A call number must be dedicated to the interface unit
z
Outgoing calls
-
One pre-programmed number in the telephone network.
-
One alternative pre-programmed number if the first number does
not answer within a specified time
z
Incoming calls
-
One preprogrammed number in the Pro700 system (call no. 13 or
the door bell function)
-
Selective dialing (any number) in the Pro700 system.
z
A programming option is to give a 4-digit password code to
incoming calls before access is given to the Pro700 system.
z
The telephone conversation may be loud-speaking and hands-free
in the Pro700 system.
FC740
10 Watt Amplifier w/ talk-back
z
10W amplifier unit for use with stations AA703, AA704, AA705 and
BC735.
z
The unit can be used as an amplifier with talk- back function or as
a plain amplifier.
z
It contains a printed circuit board NFE1832 which is a piggy-back
card for mounting on top of the station PCB NFE1830.
DP996
Sound Detection Module
z
This module is designed to be mounted inside the stations AB731,
AB731-F, AB731A and AB731A-F.
z
The circuit on the Sound Detection Module will detect voice,
screams or audible noise and then output an alarm signal.
z
The card can be configured by the installer to fit the particular
application. The loudness and length of the audio signal to activate