US and Canada call 1-800-683-2378, other countries call 1-904-641-1666
15
Outputs 170 MDC series
Dual Head
Maximum
Pump Tube
gallons
liters
gallons
liters
ounces
milliliters
liters
liters
milliliters
Dual Control
Pressure
Number
per day
per day
per hour
per hour
per minute
per minute
per day
per hour
per minute
Model
Adjustable
170MDCHP9*
100 psi / 6.9 bar
#1
0.3 to 5.0
1.1 to 18.9
0.01 to 0.21
0.05 to 0.79
0.03 to 0.44
0.76 to 13.13
0.9 to 15.1
0.4 to 0.63
0.63 to 10.49
170MDC1
25 psi / 1.7 bar
#1
170MDCHP34*
100 psi / 6.9 bar
0.8 to 17.0
3.0 to 64.4
0.03 to 0.71
0.13 to 2.68
0.07 to 1.51
2.08 to 44.65
2.4 to 51.5
0.10 to 2.15
1.67 to 35.76
170MDC2
25 psi / 1.7 bar
170MDC3
25 psi / 1.7 bar
#2
2.0 to 40.0
7.6 to 151.4
0.08 to 1.67
0.32 to 6.31
0.18 to 3.55
5.27 to 105.14
6.1 to 121.1
0.25 to 5.05
4.24 to 84.10
170MDC4
25 psi / 1.7 bar
3.0 to 60.0
11.4 to 227.1
0.13 to 2.5
0.48 to 9.46
0.27 to 5.33
7.92 to 157.71
9.1 to 181.7
0.38 to 7.57
6.32 to 126.18
170MDC5
25 psi / 1.7 bar
4.3 to 85.0
16.3 to 321.8
0.18 to 3.54
0.68 to 13.40
0.38 to 7.55
11.32 to 223.40
13.0 to 257.4
0.54 to 10.73 9.03 to 178.75
Outputs for Inner Pump Head Only
Approx. Outputs @ 60 Hz
Approx. Outputs @ 50 Hz
#1
#2
#3
#4
NOTICE:
The information within this chart is solely intended for use as a guide. The output data is an approximation based on pumping water under a controlled testing environment.
Many variables can affect the output of the pump. G. H. Stenner & Co., Inc. recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.
*pump supplied with injection check valve for 26-100 psi applications
#5
The dial ring for adjustable pumps is marked L-10; L=5%, 1-10 indicates