US and Canada call 1-800-683-2378, other countries call 1-904-641-1666
11
Double Head
Maximum
Pump Tube
gallons
liters
gallons
liters
ounces
milliliters
liters
liters
milliliters
Model
Pressure
Number
per day
per day
per hour
per hour
per minute
per minute
per day
per hour
per minute
Adjustable
170DMHP9*
100 psi / 6.9 bar
#1
0.5 to 10.0
1.9 to 37.9
0.02 to 0.42
0.08 to 1.58
0.04 to 0.89
1.32 to 26.32
1.5 to 30.3
0.06 to 1.26
1.04 to 21.04
170DM1
25 psi / 1.7 bar
#1
Fixed Output
170DMPHP9*
100 psi / 6.9 bar
10.0
37.9
0.42
1.58
0.89
26.32
30.3
1.26
21.04
170DMP1
25 psi / 1.7 bar
Adjustable
170DMHP34*
100 psi / 6.9 bar
#2
1.7 to 34.0
6.4 to 128.7
0.07 to 1.42
0.27 to 5.36
0.15 to 3.02
4.44 to 89.38
5.1 to 103.0
0.21 to 4.29
3.54 to 71.55
170DM2
25 psi / 1.7 bar
#2
Fixed Output
170DMPHP34*
100 psi / 6.9 bar
34.0
128.7
1.42
5.36
3.02
89.38
103.0
4.29
71.55
170DMP2
25 psi / 1.7 bar
Adjustable
170DM3
25 psi / 1.7 bar
#3
4.0 to 80.0
15.1 to 302.8
0.17 to 3.33 0.63 to 12.62 0.35 to 7.11
10.49 to 210.28
12.1 to 242.2 0.50 to 10.09
8.40 to 168.22
Fixed Output
170DMP3
25 psi / 1.7 bar
80.0
302.8
3.33
12.62
7.11
210.28
242.2
10.09
168.22
Adjustable
170DM4
25 psi / 1.7 bar
#4
6.0 to 120.0
22.7 to 454.2
0.25 to 5.00 0.95 to 18.93 0.53 to 10.66
15.76 to 315.42
18.2 to 363.4 0.76 to 15.14 12.64 to 252.36
Fixed Output
170DMP4
25 psi / 1.7 bar
120.0
454.2
5.00
18.93
10.66
315.42
363.4
15.14
252.36
Adjustable
170DM5
25 psi / 1.7 bar
#4
8.5 to170.0
32.2 to 643.5
0.35 to 7.08
1.34 to 26.8 0.76 to 15.10
22.36 to 446.88
25.7 to 514.8 1.07 to 21.45 17.92 to 357.50
Fixed Output
170DMP5
25 psi / 1.7 bar
170.0
643.6
7.08
26.8
15.10
446.88
514.8
21.45
357.50
Approx. Outputs @ 60 Hz
Approx. Outputs @ 50 Hz
#1
#2
#3
#4
#5
Outputs 170 series
NOTICE:
The information within this chart is solely intended for use as a guide. The output data is an approximation based on pumping water under a controlled testing environment.
Many variables can affect the output of the pump. G. H. Stenner & Co., Inc. recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.
*pump supplied with injection check valve for 26-100 psi applications
The dial ring for adjustable pumps is marked L-10; L=5%, 1-10 indicates
10% increments of maximum output. (20:1 Turndown Ratio)