INSSTCP15MA0116
8
temperature set points
The figures displayed beside the
icon indicate the ambient
(
) or the floor (
) temperature set points. They can be
displayed in degrees Celsius or Fahrenheit (see “Display in
degrees Celsius/Fahrenheit”).
Out of any adjustment mode, press down the + button to
increase the set point, or the - button to decrease it. Set points
can only be adjusted by increments of 1 degree. To quickly
scroll through the set point values, press and hold down the
button.
maximum floor temperature limitation
At any time, the floor temperature (in
mode) is maintained
at less than 28°C (82°F) in order to avoid overheating caused
by an excessive heating request, which could damage some
materials or be detrimental for health.
adjustment of the hour and the Day of the Week
Adjustment procedure of the hour and the day of the week.
1. Press down the Day/Hr button, whether it is in Man, Auto or
Pre Prog mode.
2. At this moment, the icon and the day of the week blinks
and you can adjust the day of the week using the + or -
button and confirm your choice by pressing down the Mode
or Day/Hr button. You can also press down the desired
day of the week button without using the + or - button and
confirm your choice using the Mode or Day/Hr button.
3. The two figures indicating the hour blink. You must adjust
them using the + or - button and confirm your choice by
pressing down the Mode or Day/Hr button.
4. The two figures indicating the minutes blink. You must adjust
them using the + or - button and confirm your choice by
pressing down the Mode or Day/Hr button. The adjustment
is then completed and the thermostat returns to the previous
mode.