  PROBLEM

      DEFECTIVE PART OR PART TO CHECK

The unit does not work

- Defective thermostat, wrong thermostat setting or positionning
- Open circuit breaker or fuse
- Faulty connections
- Faulty motor or condensator
- Faulty blower control switch
- Faulty transformator
- See above: CONTROL CARD AUTODIAgNOSTIC

The unit runs continuously

- Defective thermostat, wrong thermostat setting or positionning
- Heat losses greater than the unit capacity
- Faulty relay
- Thermostat wire incorrectly connected to the furnace
- See above: CONTROL CARD AUTODIAgNOSTIC

The unit cycles under control of the thermal protection (overheat 

indicator)

- Blocked air vents
- Defective motor

Overheating

- Defective thermostat, wrong thermostat setting or positionning

- Defective motor

The breaker trips when the heater is turned on

- Faulty connections

- Voltage higher than that indicated on the nameplate

Elements are on, but the motor does not work

- Defective motor or condensator

- Faulty relay

The desired room temperature cannot be reached

- One or more defective elements
- Defective thermostat or wrong thermostat setting
- Voltage lower than that indicated on the nameplate
- Heat losses greater than the unit capacity
- Faulty relay

ConTrol CArD AUToDIAGnoSTIC

The control card of the furnace is equipped with a pilot LED that allow easy and quick diagnostic of its essential functions. The yellow LED is 

located at the top right side of the control panel (item #10 of the control panel picture).
The pilot LED will start to blink continuously when an electrical problem occurs.

N.B. If you do not solve the problem after checking these points, cut off the power supply at the main electrical panel and contact 

our customer service (see the “Limited warranty” section to obtain the phone numbers).

troubleshooting

Summary of Contents for 360 Comfort

Page 1: ...r information or to consult this guide online please visit our website at www stelpro com This unit complies with the CSA and UL standards This unit is approved according to the Canadian and American...

Page 2: ...electrical wiring of the unit Because this unit is hot when in use it may pose risks even in normal operation Therefore be careful and responsible when using it To avoid burns do not let bare skin tou...

Page 3: ...s up at medium speed and the furnace elements are activated one by one to reach the adjustable temperature limit set on the potentiometer of the furnace control card If there is still a W1 heating dem...

Page 4: ...thout any heating demand Moreover it will reactivate it when a new heating season begins Note that the pilot light indicating the heating option will blink if the furnace deactivates this option becau...

Page 5: ...ndicate which installation has been programmed The heat pump can operate all year and allows the user to make energy savings due to the plenum temperature regulation function exclusive to Stelpro This...

Page 6: ...ting power will ramp up to 50 heating for five 5 minutes If a heating demand lasts 30 minutes a second sequence of five 5 minutes activates a ramp up of the elements to 100 heating at medium speed Hea...

Page 7: ...specify the model of your furnace as well as its serial number Air filter Excessive dust or dirt accumulation can block the airflow forcing the unit to work harder to maintain the desired temperature...

Page 8: ...s turned on Faulty connections Voltage higher than that indicated on the nameplate Elements are on but the motor does not work Defective motor or condensator Faulty relay The desired room temperature...

Page 9: ...10 8 2 BLO 005 SQUIRREL CAGE BLOWER 12 11 3 MO 036 1 MOTOR 208 240 VAC 1PH 1 3HP 4 SPEEDS 1075 RPM 3 MO 037 MOTOR 208 240 VAC 1 PH 1 HP 3 SPEEDS 1075 RPM 3 MO 049 MOTOR 120VAC 1PH 1 3HP 4 SPEEDS 1075...

Page 10: ...ty or personal injury damages penalties special or punitive damages damages for lost profits loss of use of equipment cost of capital cost of substitute products facilities or services shutdowns slowd...

Reviews: