4

INSSFEU0914

ConTInUoUS VenTIlATIon

Two ventilation speeds can be selected on the furnace control panel: LOW SPEED CONTINUOUS VENTILATION or hIgh SPEED CONTINUOUS 

VENTILATION. The user can select the ventilation speed by pressing the button located on the left side of the control panel (item #1 in the control 

panel picture).

ConTInUoUS HeATInG

The continuous heating option allows one or two heating elements to operate continuously. The user can select the minimum (one element) or 

maximum (two elements) continuous heating by pressing the button located on the right side of the control panel (item #7 in the control panel 

picture). Please note that for model #1021, the minimum and maximum continuous heating are the same (one element). The continuous heating 

mode is useful from the beginning to the end of the heating season since it reduces temperature variations into the house. If the minimum or 

maximum continuous heating option is activated by the user, the furnace will deactivate it when the heating season ends (more than two hours 

without any heating demand). Moreover, it will reactivate it when a new heating season begins. Note that the pilot light indicating the heating 

option will blink if the furnace deactivates this option because the heating season is over. This indicates that the continuous heating will be 

activated again at the start of the next heating season.

AIr ConDITIonInG

The furnace supplies the necessary 24V power for the thermostat relay (R-Y terminals) to control the air-conditioner compressor relay. When the 

R-Y terminals are activated, the blower starts-up at high speed. See the connection diagram.

HeAT pUMp

If a heat pump is installed in your central heating system, the Stelpro electric furnace offers the installer two types of installations: type ”A” or type 

”B”. Installation ”A” must be selected when the heat pump is installed 

A

fter the furnace (air supply), and installation ”B” must be selected when 

the heat pump is installed 

B

efore the furnace (air return), as shown in the next picture. Once again, when the R-Y terminals are activated, the 

blower starts-up at high speed. 

AIR SUPPLY

AIR RETURN

HEAT PUMP

TYPE "A"

HEAT PUMP

AIR RETURN

AIR SUPPLY

TYPE "B"

TYPE A

TYPE B

  MIN. 12"  

TYPE "A"

AIR RETURN

AIR SUPPLY

HEAT PUMP

HEAT PUMP

AIR RETURN

TYPE "B"

AIR SUPPLY

Summary of Contents for 360 Comfort

Page 1: ...r information or to consult this guide online please visit our website at www stelpro com This unit complies with the CSA and UL standards This unit is approved according to the Canadian and American...

Page 2: ...electrical wiring of the unit Because this unit is hot when in use it may pose risks even in normal operation Therefore be careful and responsible when using it To avoid burns do not let bare skin tou...

Page 3: ...s up at medium speed and the furnace elements are activated one by one to reach the adjustable temperature limit set on the potentiometer of the furnace control card If there is still a W1 heating dem...

Page 4: ...thout any heating demand Moreover it will reactivate it when a new heating season begins Note that the pilot light indicating the heating option will blink if the furnace deactivates this option becau...

Page 5: ...ndicate which installation has been programmed The heat pump can operate all year and allows the user to make energy savings due to the plenum temperature regulation function exclusive to Stelpro This...

Page 6: ...ting power will ramp up to 50 heating for five 5 minutes If a heating demand lasts 30 minutes a second sequence of five 5 minutes activates a ramp up of the elements to 100 heating at medium speed Hea...

Page 7: ...specify the model of your furnace as well as its serial number Air filter Excessive dust or dirt accumulation can block the airflow forcing the unit to work harder to maintain the desired temperature...

Page 8: ...s turned on Faulty connections Voltage higher than that indicated on the nameplate Elements are on but the motor does not work Defective motor or condensator Faulty relay The desired room temperature...

Page 9: ...10 8 2 BLO 005 SQUIRREL CAGE BLOWER 12 11 3 MO 036 1 MOTOR 208 240 VAC 1PH 1 3HP 4 SPEEDS 1075 RPM 3 MO 037 MOTOR 208 240 VAC 1 PH 1 HP 3 SPEEDS 1075 RPM 3 MO 049 MOTOR 120VAC 1PH 1 3HP 4 SPEEDS 1075...

Page 10: ...ty or personal injury damages penalties special or punitive damages damages for lost profits loss of use of equipment cost of capital cost of substitute products facilities or services shutdowns slowd...

Reviews: