3

INSSFEU0914

modES

Eco

StandaRd

HigH/HaUtE

tHERmoStat

maX

min

Low/BaSSE

sFe

serie

s

série

ConTrol pAnel

1.  

ConTInUoUS VenTIlATIon

 button: provides the    

selection of the high or low speed continuous ventilation mode.

2. 

loW SpeeD ConTInUoUS VenTIlATIon

 green LED: indicates  

 

that the low speed continuous ventilation mode is activated.

3.  

HIGH SpeeD ConTInUoUS VenTIlATIon

 green LED:  

indicates that the high speed continuous ventilation mode is 

activated.

4.  

MoDe

 button: provides the selection of the Standard or Eco mode.

5.  

STAnDArD MoDe

 green LED: indicates Standard mode is 

activated.

6. 

eCo MoDe

 green LED: indicates that the ECO mode is activated 

7.  

ConTInUoUS HeATInG

 button: allows the selection of the 

maximum or minimum continuous heating mode.

8.  

MIn ConTInUoUS HeATInG

 green LED: indicates that the 

minimum of heating capacity is activated (see the CONTINUOUS 

hEATINg section on following page).

9.  

MAX ConTInUoUS HeATInG

 green LED: indicates that the 

maximum of continuous heating mode is activated (see the 

CONTINUOUS hEATINg section on following page).

10.  

THerMoSTAT

 yellow LED: indicates that the furnace is receiving a 

heating demand from the thermostat.

leGenD

1

4

7

2

5

8

3

6

9 10

operation

HeATInG DeMAnD

one-STAGe THerMoSTAT
W1-

 The thermostat closes the R-W1 circuit, which activates 100% 

of the heating sequence. The blower starts up at medium speed and 

the furnace elements are activated one by one to reach the adjustable 

temperature limit set on the potentiometer of the furnace control card. 
If there is still a W1 heating demand after 30 minutes, the heating 

sequence continues as per the W2 sequence.

or W2- 

If there is still a W1 heating demand after 30 minutes, the 

sequence continues as follows: the blower switches to the medium 

speed and all the furnace elements are activated one by one (100% 

heating). The plenum temperature is still limited by the potentiometer 

of the control card.

TWo-STAGe THerMoSTAT

The control card of the furnace auto-detects the two stages of the 

thermostat. 

W1- 

The thermostat closes the R-W1 circuit, which activates the first 

stage of the heating sequence (±50% heating). The blower starts up 

at low speed and the furnace elements are activated one by one to 

reach the adjustable temperature limit set by the potentiometer on the 

furnace control card. 
If there is still a W1 heating demand after 30 minutes, the heating 

sequence continues as per the W2 sequence.

And/or W2- 

If the thermostat closes the R-W2 circuit, the sequence 

continues as follows: the blower switches to the medium speed and all 

the furnace elements are activated one by one (100% heating). The 

plenum temperature is still limited by the potentiometer of the control 

card.

hEATINg DEmAND, 

Standard

 mODE

 (WITh T-STAT INTELLIgENCE)

100% Heat,  

Med speed

Adjust. limit

50% Heat, 

Low speed

Adjust. limit

1 stage W1

2 stages W1

W2

W1>30 min

Activation of relays, 3-sec. interval

Summary of Contents for 360 Comfort

Page 1: ...r information or to consult this guide online please visit our website at www stelpro com This unit complies with the CSA and UL standards This unit is approved according to the Canadian and American...

Page 2: ...electrical wiring of the unit Because this unit is hot when in use it may pose risks even in normal operation Therefore be careful and responsible when using it To avoid burns do not let bare skin tou...

Page 3: ...s up at medium speed and the furnace elements are activated one by one to reach the adjustable temperature limit set on the potentiometer of the furnace control card If there is still a W1 heating dem...

Page 4: ...thout any heating demand Moreover it will reactivate it when a new heating season begins Note that the pilot light indicating the heating option will blink if the furnace deactivates this option becau...

Page 5: ...ndicate which installation has been programmed The heat pump can operate all year and allows the user to make energy savings due to the plenum temperature regulation function exclusive to Stelpro This...

Page 6: ...ting power will ramp up to 50 heating for five 5 minutes If a heating demand lasts 30 minutes a second sequence of five 5 minutes activates a ramp up of the elements to 100 heating at medium speed Hea...

Page 7: ...specify the model of your furnace as well as its serial number Air filter Excessive dust or dirt accumulation can block the airflow forcing the unit to work harder to maintain the desired temperature...

Page 8: ...s turned on Faulty connections Voltage higher than that indicated on the nameplate Elements are on but the motor does not work Defective motor or condensator Faulty relay The desired room temperature...

Page 9: ...10 8 2 BLO 005 SQUIRREL CAGE BLOWER 12 11 3 MO 036 1 MOTOR 208 240 VAC 1PH 1 3HP 4 SPEEDS 1075 RPM 3 MO 037 MOTOR 208 240 VAC 1 PH 1 HP 3 SPEEDS 1075 RPM 3 MO 049 MOTOR 120VAC 1PH 1 3HP 4 SPEEDS 1075...

Page 10: ...ty or personal injury damages penalties special or punitive damages damages for lost profits loss of use of equipment cost of capital cost of substitute products facilities or services shutdowns slowd...

Reviews: