Page 57
INS_CLX58-AF Rev D
24 - LPC - CXL CONVERSION KIT INSTRUCTIONS
Figure 24E.1
NG Position
*=:,';Q'&/&\d
:
If converting from NAT to LP gas:
mVn
If converting from LP to NAT gas:
m]n
1. , !
2. cd
°
,>
m)\^=Vn
3. , hm m)-
\^)n,
1.
Adjust burner venturi setting by loosening nut, sliding shutter and retightening nut.
CORRECT SETTINGS: NAT. : 1/4” (6 mm) open L.P. : 3/8” (10 mm) open
Note: Venturi may need further adjustment, depending on your venting configuration.
9|}'
2.
Re-install burner assembly into fireplace, checking to ensure burner end is properly seated on burner orifices. Install the left burner
leg.
3.
Extinguish the fireplace.
4.
Re-install the log tray (CTL-58) or glass media tray (CML-58).
5.
Re-install logs (CTL-58) or glass panels and glass bead media (CML-58).
6.
Turn on gas and electrical supplies.
7.
Light fireplace*. Check for leaks at all connections with a soapy leak-check solution, whether field or factory made.
8.
Test inlet pressure.
9.
Visually check pilot flame. Flame should envelope top of flame sensor and extend onto burner far enough for proper ignition.
To Adjust Pilot: Turn pilot adjustment screw clockwise to decrease or counter-clockwise to increase pilot flame.
10. Turn fireplace off.
11. Affix gas type sticker to existing label.
12. Reinstall glass frame assembly and front.
►
►
PILOT
ADJUSTMENT
SCREW
LOW LIMIT
SCREW
▲
▲
▲
IGNITOR
FLAME
SENSOR
PILOT NUT
Figure 24F
▼
PRESSURE REGULATOR CAP
Figure 24B
D. GAS TYPE CONVERSION
E. CONVERT GAS CONTROL VALVE:
F. COMPLETE THE CONVERSION
Figure 24E.2
LP Position