26
Item
Operations
Display
Notes
Turn on the scale, long press
and quickly
press
two times, and enter
to calibrate
SETUP
Position of decimal
point
Press
to choose, press
to confirm
<Pot>
0: XXXXX
1: XXXX,X
2: XXX,XX
3: XX,XXX
Capacity
Press
to add unit one, press
<
to move left one, press
to confirm it
<3000>
Division
press
to choose, press
to confirm.
<FD>
E.g.: 50g
,choose “5”,
100g choose
”1”
No need to set. Enter next step by
pressing
CAL
Auto enter to next step, no need
to set
<26000>
Input the value of standard weight
which was loaded before (e.g.
100kg) by pressing to add 1, and
pressing to move the digit to the
left. After inputting the value, press
to confirm
<25.5>
End of calibration
<Done>
5. CALIBRATION
applicable to scale models SBS-KW-300AW, SBS-KW-300AB and
SBS-KW-300AR
27
Item
Operations
Display
Notes
Press
simultaneously,
and keep pressing for
1 second.
SETUP
Press
simultaneously,
and keep pressing
for 1 second.
P0000
Press
to increase
flashing digital. Press to
move flashing digital. Input
Scale Configuration Password.
P0258
Password:
0258
Press
to confirm password.
SCALE
User‘s gravity
Press
to enter User
Gravity parameter.
Press
to increase
flashing digital, press to
move flashing digital, input
gravity where scale is used.
09,807
Press
to exit the configurati
-
on menu of the scale
End
6. SCALE CONFIGURATION
applicable to scale models SBS-KW-300AW, SBS-
KW-300AB and SBS-KW-300AR
EN
EN