![Stegmaier-Haupt TV 6.2 Manual Download Page 5](http://html.mh-extra.com/html/stegmaier-haupt/tv-6-2/tv-6-2_manual_1370364005.webp)
TV6.2
5
1 Basic Information
Technical data
TV6.2
Power connection only via an isolating transformer
No galvanic isolation between the power section and the control electronics.
Power connection
TV6.2
30 to 120V~, 40 to 160V=
Output voltage
TV6.2
24 to 120V= clock-pulse controlled
Cooling
self
Device TV6.2
12
Output current
continuous
A=
12
peak
A=
24
Max. el. power
W
1440
Integrated quick fuses
A
16
Armature choke
type
DR42 (0.5 mH)
Dimensions - plug-in device
wxh
16TE
6HE
Dimensions - switch cabinet plug-in device
wxhxd
170x240x80 mm
Common specification
Protection rating
IP 00
Format
VDE 0100 group C
VDE 0160
Humidity rating
class F acc. to DIN 40040
Site of installation
< 1000m above sea level
Operating temperature range
0 to 45°C
Extended operating temperature range
up to 60°C reduced by 2%/°C
Storage temperature range
-30°C to +80°C
Speed controller:
control precision without actual value error
± 0.1%
Control range
1: 1000
Summary of Contents for TV 6.2
Page 12: ...Transistor Servo Drive TV 6 2 12 ...
Page 13: ...TV6 2 13 3 Mechanical Installation ...
Page 14: ...Transistor Servo Drive TV 6 2 14 ...
Page 15: ...TV6 2 15 3 Mechanical Installation ...
Page 17: ...TV6 2 17 4 Adjustments Anschluss Kompaktgerät Anschluss Mehrachskombination ...
Page 38: ...Transistor Servo Drive TV6 2 38 ...
Page 39: ...TV6 2 39 8 Circuit Diagrams ...
Page 40: ...Transistor Servo Drive TV6 2 40 ...
Page 41: ...TV6 2 41 8 Circuit Diagrams ...