STEALTH DIGI-ARC 160LT
9
6.2 Welding Table
Note: The following table applies to low-carbon steel. For other materials, please refer
to related information.
Electrode diameter
Recommended welding
Recommended welding
(mm)
current (A)
voltage (V)
1.0
20~60
20.8~22.4
1.6
44~84
21.76~23.36
2.0
60~100
22.4~24
2.5
80~120
23.2~24.8
3.2
108~148
23.32~24.92
4.0
160~200
26.4~28
5.0
180~260
27.2~30.4
7. Operation Notices
7.1 Installation
7.1.1 Welding environmental temperature should be between –10ºC to 40ºC.
7.1.2 Welding should be completed in relatively dry environments with air humidity of
not more than 90%.
7.1.3 Avoid environments containing dust or corrosive gases.
7.1.4 Avoid sunlight or rain. Do not allow water or rain water to infiltrated the welding
machine.
7.1.5 Avoid a strong air flow environment when gas welding.
7.2 Safety
This welding machine has been installed with a over-voltage, over-current and
over-temperature protection circuit. When the grid voltage, output current and internal
temperatures exceed the set temperature, the welding machine will automatically
cease working. Excessive use will result in welding damage, so please note:
7.2.1 Ensure good ventilation
The Digi-Arc 140LT DV is equipped with cooling fans. Before use, please check
the vents are clear and the distance surrounding welding is not be less than 0.3
metres.
7.2.2 Prevent overload
The welder should ensure that the duty cycle current is kept within the standard
range (see technical data table). Any current overload will shorten the life of
the machine welding machine and may even ignite.