8 PROsine 2.5/3.0 Advanced Control System (ACS) Owner’s Manual
2.2.2. BATTERY INFO
MENU OPTION
DISPLAY
DESCRIPTION
2.2.3. INVERTER
MENU OPTION
DISPLAY
DESCRIPTION
Note
: The DC input ranges are factory configured for the maximum range allowed for proper operation of
the PROsine 2.5/3.0 Inverter•Charger. The installer may wish to narrow this range of operation for
optimization of the system. For example, the LO ALARM setpoint could be raised to 11.5V if you want an
early warning that the battery is being discharged. Or, raising the LO CUTOFF to 11.0V would ensure that
the battery is never fully discharged.
SELECT FROM:
AC INFORMATION
SELECT FROM:
BATTERY
BATTERY INFO:
TYPE: FLOODED
BATTERY INFO:
SIZE:
200 Ah
BATTERY INFO:
TEMP: COLD
INSTALLER SETTABLE
: adjustable
between FLOODED or GEL batteries
INSTALLER SETTABLE
: adjustable from
50 Ah to >2000 Ah
USER SETTABLE
: adjustable from COLD
(ambient <10C, 50F), WARM (10C, 50F to
27C, 80F), and HOT (>27C, 80F). Set to
best match ambient conditions giving
batteries a temperature-compensated charge.
If battery temperature sensor is attached, then
this display shows actual battery temperature
and is not adjustable. Press
ENTER
then
▲
or
▼
to change between C and F.
LOAD SENSE
TURN-
ON POWER: 0 W
LOAD SENSE
INTERVAL:
2.0 s
DC INPUT RANGE:
LO ALARM:
10.5 V
USER SETTABLE
: adjustable between 0
and 1401 watts, 0 = Search mode disabled
USER SETTABLE
: from 2 to 26.5 seconds.
Longer delay = lower standby power draw
SELECT FROM:
AC INFORMATION
SELECT FROM:
BATTERY
SELECT FROM:
INVERTER
DC INPUT RANGE:
HI ALARM:
15,5 V
DC INPUT RANGE:
LO CUTOFF: 10.0 V
DC INPUT RANGE:
HI CUTOFF: 16.0 V
INSTALLER SETTABLE
: from 10-12V
on 12V products or 20-24V on 24V products
INSTALLER SETTABLE
: from 14-16V
on 12V products or 28-32V on 24V products
INSTALLER SETTABLE
: from 10-12V
on 12V products or 20-24V on 24V products
INSTALLER SETTABLE
: from 14-16V
on 12V products or 28-32V on 24V products
Summary of Contents for Prosine 2.5