3

TABLE 1C - HEATER PERFORMANCE DATA SBD MODELS

INPUT

APPROX.

RECOVERY RATING CAPACITIES (GPH AND LPH)

RATE

GAL

EFF.

30° F 40° F 50° F 60° F 70° F 80° F 90° F 100° F 110° F 120° F 130° F 140° F

MODEL

BTUH

CAP.

%

(-) 1 C

4 C

10 C

15 C 21 C

27 C

32 C

38 C

43 C

49 C

54 C

60 C

SBD71120

120,000 BTUH

71 Gal

80

388

291

233

194

166

145

129

116

106

97

90

83

35 kW/Hr

268 L

1469

1102

882

734

628

549

488

439

401

367

341

314

SBD81154

154,000  BTUH

81 Gal

80

498

373

299

249

213

187

166

149

136

124

115

107

45 kW/Hr

306 L

1885

1412

1132

943

806

708

628

564

515

469

435

405

SBD81180

180,000 BTUH

81 Gal

80

579

434

347

289

248

217

193

174

158

145

134

124

53 kW/Hr

306L

2192

1643 1314

1094

939

821

731

659

598

549

507

469

SBD100199* 199,000 BTUH

100 Gal

80

643

482

386

322

276

241

214

193

175

161

148

132

58 kW/Hr

379 L

2434

1825 1461

1219 1045

912

810

731

662

609

560

500

SBD100199

199,000 BTUH

100 Gal

80

643

482

386

322

276

241

214

193

175

161

148

132

58 kW/Hr

379L

2434

1825 1461

1219 1045

912

810

731

662

609

560

500

SBD81190

190,000 BTUH

81 Gal

80

614

461

368

307

263

230

205

184

167

154

142

132

56 kW/Hr

306 L

2324

1745 1393

1162

996

871

776

697

632

583

538

500

SBD100199** 199,000 BTUH

100 Gal

80

643

482

386

322

276

241

214

193

175

161

148

132

58 kW/Hr

379 L

2434

1825 1461

1219 1045

912

810

731

662

609

560

500

SBD100250

250,000 BTUH

100 Gal

80

808

606

485

404

346

303

269

242

220

202

186

173

73 kW/Hr

379 L

3059

2294 1835

1529

1311 1147 1020

918

834

765

706

655

SBD65251

251,000 BTUH

65 Gal

80

811

608

487

406

348

304

270

243

221

203

187

174

73 kW/Hr

246 L

3071

2303 1843

1536 1316 1152 1024

921

838

768

709

658

SBD100275

275,000 BTUH

100 Gal

80

889

667

533

444

381

333

296

267

242

222

205

190

80 kW/Hr

379 L

3365

2524 2019

1682 1442 1262

1122 1009

918

841

776

721

SBD65305

305,000 BTUH

65 Gal

80

986

739

592

493

423

370

329

296

269

246

228

211

89 kW/Hr

246 L

3732

2799 2239

1866 1599 1399

1244

1120 1018

933

861

800

SBD85365

365,000

85 Gal

80

1180

885

708

590

506

442

393

354

322

295

272

253

107 kW/Hr

322 L

4466

3349 2680

2233 1914 1675

1489 1340

1218

1116

1031

957

SBD100399

399,000 BTUH

100 Gal

80

1293

970

776

646

554

485

431

388

353

323

298

277

117 kW/Hr

379 L

4894

3671 2936

2447 2097 1835

1631 1468

1335

1224

1129

1049

SBD85500

500,000 BTUH

85 Gal

80

1616

1212

970

808

693

606

539

485

441

404

373

346

147 kW/Hr

322 L

6118

4588 3671

3059 2622 2294

2039 1835

1668

1529

1412

1311

* Tall models.

** Short models.

TABLE 1D - HEATER PERFORMANCE DATA SBD (CGA) MODELS

INPUT

APPROX.

RECOVERY RATING CAPACITIES (GPH AND LPH)

(CGA)

RATE

GAL

EFF.

30° F

40° F

50° F 60° F 70° F

80° F 90° F 100° F 110° F 120° F 130° F 140° F

MODEL

BTUH

CAP.

%

(-) 1 C

4 C

10 C

15 C

21 C

27 C

32 C

38 C

43 C

49 C

54 C

60 C

SBD71120

120,000 BTUH

71 Gal

80

388

291

233

194

166

145

129

116

106

97

90

83

35 kW/Hr

268 L

1469

1102

882

734

628

549

488

439

401

367

341

314

SBD81154

154,000  BTUH

81 Gal

80

498

373

299

249

213

187

166

149

136

124

115

107

45 kW/Hr

306 L

1885

1412

1132

943

806

708

628

564

515

469

435

405

SBD76180

180,000 BTUH

76 Gal

80

579

434

347

289

248

217

193

174

158

145

134

124

53 kW/Hr

288L

2192

1643 1314

1094

939

821

731

659

598

549

507

469

SBD95199

199,000 BTUH

95 Gal

80

643

482

386

322

276

241

214

193

175

161

148

132

58 kW/Hr

360 L

2434

1825 1461

1219

1045

912

810

731

662

609

560

500

SBD76190

190,000 BTUH

76 Gal

80

614

461

368

307

263

230

205

184

167

154

142

132

56 kW/Hr

288 L

2324

1745 1393

1162

996

871

776

697

632

583

538

500

SBD100199 199,000 BTUH

100 Gal

80

643

482

386

322

276

241

214

193

175

161

148

132

58 kW/Hr

379 L

2434

1825 1461

1219

1045

912

810

731

662

609

560

500

SBD100250 250,000 BTUH

100 Gal

80

808

606

485

404

346

303

269

242

220

202

186

173

73 kW/Hr

379 L

3059

2294 1835

1529

1311

1147

1020

918

834

765

706

655

SBD65251

251,000 BTUH

65 Gal

80

811

608

487

406

348

304

270

243

221

203

187

174

73 kW/Hr

246 L

3071

2303 1843

1536

1316

1152

1024

921

838

768

709

658

SBD100275 275,000 BTUH

100 Gal

80

889

667

533

444

381

333

296

267

242

222

205

190

80 kW/Hr

379 L

3365

2524 2019

1682

1442 1262

1122

1009

918

841

776

721

SBD65305

305,000 BTUH

65 Gal

80

986

739

592

493

423

370

329

296

269

246

228

211

89 kW/Hr

246 L

3732

2799 2239

1866

1599 1399

1244

1120

1018

933

861

800

SBD65365

365,000 BTUH

65 Gal

80

1164

873

698

582

499

436

388

349

317

291

269

249

107 kW/Hr

246 L

4405

3304 2643

2202

1888 1652

1468

1321

1201

1101

1016

944

SBD100399 399,000 BTUH

100 Gal

80

1293

970

776

646

554

485

431

388

353

323

298

277

117 kW/Hr

379 L

4894

3671 2936

2447

2097 1835

1631

1468

1335 1224

1129

1049

SBD85500

500,000 BTUH

85 Gal

80

1616

1212

970

808

693

606

539

485

441

404

373

346

147 kW/Hr

322 L

6118

4588 3671

3059

2622 2294

2039

1835

1668 1529

1412

1311

Summary of Contents for SBD100399

Page 1: ...FYOWNERTOKEEPFORFUTUREREFERENCE PrintedinU S A 0203 PARTNO 195121 000 CAUTION TEXT PRINTED OR OUTLINED IN RED CONTAINS INFORMATION RELATIVE TO YOUR SAFETY PLEASE READ THOROUGHLY BEFORE INSTALLING AND...

Page 2: ...0 000 BTR Hr 85 Gal 82 25 4 50 73 50 65 25 25 50 21 1 65 75 8 27 75 1 50 1 50 1 50 1 50 1 50 1 50 745Lbs 857Lbs 147kW Hr 322L 209cm 12cm 187cm 166cm 65cm 53cm 1 167cm 20cm 70cm 1 50 1 50 1 50 1 50 1 5...

Page 3: ...BD85500 500 000 BTUH 85 Gal 80 1616 1212 970 808 693 606 539 485 441 404 373 346 147 kW Hr 322 L 6118 4588 3671 3059 2622 2294 2039 1835 1668 1529 1412 1311 Tall models Short models TABLE1D HEATERPERF...

Page 4: ...input of 305 000 89 kWh 365 000 107 kWh 399 000 117 kWh and 500 000 147 kWh Btuh with a recovery rating of 277 3 gph 1049 Lph or more also comply with ANSI Z21 10 3 as an automatic instantaneous type...

Page 5: ...having a cold or diminishing sense of smell with age For these reasons the use of a propane gas detector is recommended IF YOU EXPERIENCE AN OUT OF GAS SITUATION DO NOT TRY TO RELIGHTAPPLIANCES YOURS...

Page 6: ...reduction required at high altitudes the output rating of the appliance is reduced and should be compensated for in the sizing of the equipment for application FEATURES SELF CLEANING HYDRO CANNON Thes...

Page 7: ...I NFPA No 70 For Canada refer to Canadian Code CSA C22 1 Only all bronze circulators should be used with commercial water heaters Although circulators are oiled and operated by the manufacturer some c...

Page 8: ...the unit is not level insert the bolts which were used in crating into the legs to correct this condition CLEARANCES These heaters are approved for installation on combustible flooring in an alcove wh...

Page 9: ...lution must be obtained from outdoors The installation instructions for confined spaces in tightly constructed buildings must be followed to ensure adequate air supply CONFINEDSPACE When drawing combu...

Page 10: ...by means of a circulating pump When a circulating pump is used it is important to note that the flow rate should be slow so that there will be a minimum of turbulence inside the heater If a water hea...

Page 11: ...197 198 199 200 Input 180 000 190 000 199 000 Btuh Total Vent Height Feet Draft Hood 6 6 8 10 15 20 30 50 100 Input Btuh Rise Vent Connector Diameter in inches 180 000 1 Ft 8 8 8 8 8 7 7 7 190 000 8 8...

Page 12: ...10 10 8 8 8 Number of Combined Input Heaters in Thousands of Btuh Manifold Common Vent Diameter 2 610 14 14 12 12 12 10 10 10 3 915 16 16 16 14 14 12 12 12 4 1220 18 18 16 16 16 14 14 12 MODEL 365 40...

Page 13: ...0 60 66 138 260 530 810 1520 2400 4300 8800 70 61 125 240 490 750 1400 2250 3900 8100 80 57 118 220 460 690 1300 2050 3700 7500 90 53 110 205 430 650 1220 1950 3450 7200 100 50 103 195 400 620 1150 18...

Page 14: ...e controls The minimum gas supply pressure for input adjustment must FIGURE 10 SINGLE UNIT WIRING DIAGRAM SBD MODELS 120 THROUGH 500A not be less than 4 5 W C 1 12 Kpa for natural gas and 11 0 W C 2 7...

Page 15: ...f applying heat to this fitting Do not allow pipe dope to contact the plastic tube during installation CODE RESTRICTIONS Use of the top inlet water connection is not permitted on installations in the...

Page 16: ...LD NOT EXCEED SAFE USE TEMPERATUREAT FIXTURES SEE WATER TEMPERATURE CONTROL WARNING ON PAGE 27 IF HIGHER PREHEAT TEMPERATURES ARE NECESSARY TO OBTAIN ADEQUATE BOOSTER OUTPUT ADD AN ANTI SCALD VALVE FO...

Page 17: ...GLESWITCHMUSTBECLOSED ON DURING THERINSEOPERATIONANDOPEN OFF WHENDISHWASHER IS NOTOPERATING OR WHEN ON LONG STANDBY NOTE 2 INSTALLLINETEMPERATURECONTROLINANUNINSULATED TEEBEYONDTHEDISHWASHINGMACHINETA...

Page 18: ...in the installation diagrams on the following pages are typical TWO TEMPERATURE TWO HEATERS ONE PRE HEATER ONE BOOSTER HEATER WITH OR WITHOUT BUILDING RECIRCULATION The discharge opening of the temper...

Page 19: ...OTE 3 ADJUST PLUG COCK SO THE SANITIZING LOOP FLOW RATE DOES NOT CAUSE UNNECESSARY TURBULENCE IN THE TANK PIPE RELIEF VALVE TO OPEN DRAIN INSTALL IN ACCORDANCE WITH LOCAL CODES CIRCULATING RETURN LINE...

Page 20: ...HER PREHEAT TEMPERATURES ARE NECESSARY TO OBTAIN ADEQUATE BOOSTER OUTPUT ADD ANANTI SCALD VALVE FOR HOT WATER SUPPLIED TO FIXTURES INSERT A CAUTION IF BUILDING COLD WATER SUPPLY HAS A BACKFLOW PREVENT...

Page 21: ...STER OUTPUT ADD AN ANTI SCALDVALVE FOR HOT WATER SUPPLIED TO FIXTURES PIPE RELIEF VALVE TO OPEN DRAIN WHEN USING A STATE T 140 200 350 OR 400 STORAGE TANK USE LOWER 3 4 OPENING FOR TANK TEMPERATURE CO...

Page 22: ...SBDMODELS 120 69 75 177cm 69 75 177cm 154 73 00 185cm 73 00 185cm 180 67 50 171cm 70 50 179cm 197 75 00 192cm 81 50 207cm 198 75 00 192cm N A 199 67 50 171cm 70 50 179cm 200 72 00 183cm 72 00 183cm 2...

Page 23: ...installation manual for complete instructions MULTIPLE UNIT INSTALLATIONS For multiple unit installations contact State Water Heaters Technical Support Center at 1 800 527 1953 TABLE5 MANIFOLDGASPRES...

Page 24: ...ION PURGE DISCHARGE MUST NOT ENTER CONFINEDAREAS OR SPACES WHERE IGNITION CAN OCCUR THE AREA MUST BE WELL VENTILATED AND ALL SOURCES OF IGNITION MUSTBE INACTIVATED OR REMOVED WARNING THE GAS VALVE MUS...

Page 25: ...SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER E DO NOT OPERATE APPLIANCE UNLESS UNIT IS FILLED WITH WATERAND INLET LINES AFTER FULLY OPEN WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTL...

Page 26: ...L SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER E DO NOT OPERATE APPLIANCE UNLESS UNIT IS FILLED WITH WATERAND INLET LINESAFTER FULLY OPEN WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACT...

Page 27: ...e the damper disc manually or motor damage will occur If the water heater does not operate with the Service Switch in either position Refer to the Troubleshooting Sections and Operational Checklist se...

Page 28: ...n PREVENTIVE MAINTENANCE CHECK THE PILOT At least once a year check the pilot burner fig 15 and the main burner fig 16 for proper operation Refer to the following pilot and main burner sections PILOT...

Page 29: ...the gauge port and refer to Table 5 for correct manifold pressure 2 Use this formula to clock the meter Be sure that other gas consuming appliances are not operating during this interval 3600 X H Btuh...

Page 30: ...heater and replacement of the factory installed magnesium anodes with aluminum anodes may correct the condition Occasionally water softener companies recommend removal of heater anodes for odor reason...

Page 31: ...ex head screws securing tank cleanout plate and remove plate 4 Remove lime scale or sediment using care not to damage the glass lining 5 Inspect cleanout plate gasket if new gasket is required replace...

Page 32: ...ount of UN LIME If the material is vigorously dissolved by the UN LIME it can be reused if not the UN LIME should be replaced TROUBLESHOOTING IGNITION MODULE SYSTEM Before calling your service agent t...

Page 33: ...breaker 5 Disconnect switch off 6 Harness not plugged into appliance receptacle A FLUE DAMPER OPEN OR OPENING Unit is calling for heat and damper disc should be in vertical position VOLTAGE ACROSS 4...

Page 34: ...slower Call serviceman Check gas input If incorrect adjust gas pressure or replace main burner orifice Draft hood not installed or Call serviceman Install draft hood or baffles as one or more flue ba...

Page 35: ...35...

Page 36: ...36 500 Lindahl Parkway Ashland City TN 37015 Phone 800 821 2017 Fax 800 644 9306 www stateind com...

Reviews: