Stat-X SDRP Installation, Operation And Owner'S Manual Download Page 21

Fireaway Inc.

 

 

Version 1 

5852 Baker Road 

 

10/2017 

Minnetonka, MN 55345 

 

P/N 19112 

 

21 

 

7. System Parts List and Replacement Parts List 

 

Part 
Number 

Component Description 

830001 

Control Panel, SDRP, Battery Powered Panel,  

830002 

Module, Test,  

830003 

Switch, Toggle, Manual Release,  

830006 

Cable Assy, SDRP, Battery Powered Panel,  

(

24” Unterminated Actuation Leads) 

830007 

EOL Assy, Detection, Class B, Deutsch 

830009 

Battery Kit, Replacement for 830001, LiSOCl 

830010-xxx 

Sensor, Spot Thermal, Thermotech xxx deg F, Vertical Internal 

830011-xxx 

Sensor, Spot Thermal, Thermotech xxx deg F, Vertical All Weather 

830012-xxx 

Sensor, Spot Thermal, Thermotech xxx deg F, Vertical All Weather 1/2 Conduit 

830013-xxx 

Sensor, Spot Thermal, Thermotech xxx deg F, Explosion Proof 

830020-xxx 

Linear Thermal Wire, 155

o

F Type XCR, xxx' length 

830021-xxx 

Linear Thermal Wire, 190

o

F Type XCR 

830022-xxx 

Linear Thermal Wire, 220

o

F Type XCR 

830023-xxx 

Linear Thermal Wire, 280

o

F Type XCR 

830024-xxx 

Linear Thermal Wire, 356

o

F Type XCR 

830025-xxx 

Linear Thermal Wire, 135

o

F Type XLT 

 

8. Miscellaneous Notes 

 

a.  Battery Storage 

 

STORAGE: Store in a cool, regulated (preferably below 21°C and in any case below 
30°C), dry and ventilated area, away from possible sources of heat, open flames, food 
and drink. Avoid exposure to direct sunlight for long periods. Temperatures above 100°C 
(or higher for high temperatures cells and batteries such as the LSH20-150 cell, refer to 
individual data sheets for maximum temperatures) may cause leakage and rupture, and 
result in shortened battery service life. Keep proper clearance space between batteries 
and walls. A short circuit can cause burn hazard, leakage or explosion hazard. Keep 
batteries in original packaging until use and do not mix them. 

 

HANDLING:  

 Do not open the battery system.  
 Do not crush or pierce the cells.  
 Do not short (+) or (-) terminal with conductors.  
 Do not reverse the polarity.  
 Do not submit to excessive mechanical stress.  
 Do not mix batteries of different types or mix new and old batteries together.  
 Do not use the unit without its electronic management system.  
 Do not expose the unit to water or condensation.  
 Do not directly heat, solder, or throw into fire.  

 
 
 
 

Summary of Contents for SDRP

Page 1: ...Stat X Dual Release Panel SDRP Installation Operation and Owner s Manual...

Page 2: ...erview 3 Component Description a Control Panel b Cable Harness c Alarm Test Module d Detection Wiring e Actuation Wiring 4 System Design and Installation 5 Inspection and Maintenance 6 System Alarms a...

Page 3: ...t aluminum enclosure surrounds the military qualified electronic components The SDRP provides electrical supervision of fire detection release manual activation as well as battery condition The SDRP i...

Page 4: ...rom the elements it s always good practice to keep electronics away from water oil and other conductive materials Ensure the SDRP is not located in the hazard area and is protected in some manner agai...

Page 5: ...ion and Operation Stat X generators must be securely mounted and aimed per the Hazard Analysis Field wiring from the SDRP to each generator may be wired in series or in parallel Only two generators ma...

Page 6: ...igure 2 SDRP Controls and Indications Figure 3 SDRP Labeling The SDRP panel includes two detection zones and two releasing zones The SDRP can be ordered in one of two programming configurations Serial...

Page 7: ...Input Switch will also actuate both actuation zones PN 830001 01 Dual Detection Zones and Dual Releasing Zones Each detection zone will actuate individual separate actuation zones A single dedicated...

Page 8: ...s use color coded ty wraps along with labels which indicate the cable wire function Note It s important to note that while the Stat X generators are not polarized the Alarm Test Module PN 830002 which...

Page 9: ...he ability to live test the SDRP panel and detection circuitry When a detection circuit closes in Alarm the Alarm Module senses the electrical load and simulates a system actuation A red LED in the Al...

Page 10: ...roven MIL 26482 metal shell connector to link the manual switch to the SDRP panel manual release input circuit The normally open toggle switch used with the Manual Release Switch is protected by a lab...

Page 11: ...n End of Line device completing a loop back to the SDRP If a Fire occurs the outer and inner insulating jackets of the linear thermal wire melt allowing the individual conductors of the linear thermal...

Page 12: ...gh an end of line device completing a loop back to the SDRP If a fire occurs the normally open contacts in the spot thermal close This change in electrical resistance is interpreted by the SDRP as a f...

Page 13: ...The end of line device EOL PN 830007 provides a series resistance of 470k ohms The EOL consists of a two position Deutsch connector with an over molded 470k ohm resistor The EOL provides a high resist...

Page 14: ...he SDRP and each spot thermal detector must be at a minimum UL Listed Plenum wire 18 awg Parallel field wiring is used between detectors Detection field wiring must be protected in emt conduit between...

Page 15: ...s easily supervised by the SDRP Parallel field wiring is acceptable but must be protected in emt conduit as individual Stat X generators are not supervised by the SDRP Wiring connections must be secur...

Page 16: ...k Manual Release Switch for any damage or other changes Annual Inspection 1 Before performing any detection circuit tests attach alarm module PN 830002 to both SDRP actuation circuits 2 Flip the test...

Page 17: ...ly use our PN 830009 as a replacement 1 See figures 10 11 below 2 Remove panel from mounting position 3 Remove pull pin and flip toggle switch to Disable System position 4 Replace pull pin 5 Disconnec...

Page 18: ...Fireaway Inc Version 1 5852 Baker Road 10 2017 Minnetonka MN 55345 P N 19112 18 Figure 16 SDRP battery replacement data to be completed annually when batteries are replaced...

Page 19: ...nt Panel Display System OK Green LED ON System Trouble Yellow LED OFF Indicates Status Detection Field Wiring Continuous circuit with correct resistance Actuation Field Wiring Continuous circuit with...

Page 20: ...generator to field wiring connection is intact Check for corrosion at Stat X generator to field wiring connection Check actuation circuit for any breaks or damage Verify Stat X generator has not disc...

Page 21: ...F Type XCR 830025 xxx Linear Thermal Wire 135o F Type XLT 8 Miscellaneous Notes a Battery Storage STORAGE Store in a cool regulated preferably below 21 C and in any case below 30 C dry and ventilated...