background image

Alternatively if you only require one time period per day press the SET/RESET button to cycle through time a speed settings 
of the remaining TIMERS ensuring all start and stop times are set to zero's or to the same time period. Please note all 
settings for AUTO MODE 1 to 4 will be retained in the event of power loss.

After all timers have been set.The CLEVER-POOL will then start and stop the pump at set times and speeds.

- 17 -

Summary of Contents for Clever-Pool M/220V

Page 1: ...d by STARMATRIX GROUP INC Installation Operation Maintanence Instructions Read this manual carefully before commencing installation WWW STARMATRIX CN Please leave this instruction booklet with the owner as it contains important maintanence and safty information 1 ...

Page 2: ... 7 3 2 WIRE CONNECTION 8 3 2 1 WIRE CONNECTION AND DESCRIPTION FOR 2HP AC220V SINGLE PHASE IN SINGLE PHASE OUT 8 3 2 2 WIRE CONNECTION AND DESCRIPTION FOR 3HP AC220V SINGLE PHASE IN THREE PHASE OUT 9 3 2 3 WIRE CONNECTION AND DESCRIPTION FOR 5HP AC380V THREE PHASE IN THREE PHASE OUT 10 3 3 RUNNING 10 3 3 1 CHECK BEFORE RUNNING 10 3 3 2 PROGRAMMING GUIDE 11 2 PRODUCT DIMENSION AND PARAMETERS 3 INST...

Page 3: ...the control panel before power connection to avoid eletricity shock or explosion 3 Please make sure not to confuse the input and output terminals 5 Please DO NOT touch the wire terminals when power is connected 7 Please DO NOT use wet hands for operation 6 Please wait after 10 minutes after the power is cut off when all the indication lights are off for further maintanence 8 Please ask for profess...

Page 4: ... do not connect to power supply 5 Do not disconnect the wire connection if power is connected serious personal damage will occure if against this rule 8 Make sure air ventilation when in summer or high ambient temperature use this will avoid condensate water formed and electrical faulty 1 SAFTY AND CAUTION 1 Installation based on local safty rules 2 Only professionals for installation and maintane...

Page 5: ...electromagnetic interference No rain drops or wet enviroment 1 SAFTY AND CAUTION 1 3 ENVIROMENT CAUTION The correct enviroment for our Clever Pool determines its right function and life So the installation must obey below Indoor use Ambient temperature 10 40 No direct sunshine No oil or salt 5 ...

Page 6: ...t frequency 50 60Hz 50 60Hz 50 60Hz Output voltage 1 220V 3 220V 3 380V PUMP TYPE SINGLE PHASE THREE PHASE THREE PHASE Max Power MAX 2HP MAX 3HP MAX 5HP Max current 12A 10A 10A Mode option Cooling 2 DIMENSION AND PARAMETERS Motor speed range 2 1 DIMENSION AND TECHNICAL PARAMETERS Dimension PARAMETER SHEET 50Hz 1200 3000rpm 60Hz 1200 3600rpm Manual or Auto By air 6 ...

Page 7: ...uction and use screws as shown 2 to fix 3 INSTALLATION AND FUNCTION EXPLANATION power supply socket 6 Strictly follow the operation steps as indicated in this manual 2 Put plate 1 in your installation place plate 1 3 Put the control box 4 on plate 1 and fix with screws as shown 3 4 Connect the plug from pump to the part as shown 6 5 Connect plug 5 as shown to the correct 7 ...

Page 8: ...CTION EXPLANATION 9 Power supply connected only after the control panel is fixed 1 Disconnect power before opening the control panel 2 Make sure no connection between PE N L1 termials and U V terminals 3 Wire connection operated only when power disconnected 4 Check if the input voltage from the power supply is compliance with clever pool 5 No voltage duration test 6 Screw torque for terminal screw...

Page 9: ...rom the power supply is compliance with clever pool 5 No voltage duration test 6 Screw torque for terminal screws more than 1 7N m 7 Ground link must be connected before operation 8 Must use the copper wires over 3G2 0mm2 9 Power supply connected only after the control panel is fixed Procedure and instruction 1 Disconnect power before opening the control panel 2 Make sure no connection between PE ...

Page 10: ...TCH Procedure and instruction 1 Disconnect power before opening the control panel 2 Make sure no connection between PE T S R termials and U V W terminals 3 Wire connection operated only when power disconnected 4 Check if the input voltage from the power supply is compliance with clever pool 5 No voltage duration test 6 Screw torque for terminal screws more than 1 7N m 7 Ground link must be connect...

Page 11: ... modes Manual mode and Auto mode 5 Check if the contral panel is well closed 1 1 Manual mode is used when you are connecting to a pool chlorinator or timer The system time settings are not required to run in this mode 1 2 Auto mode is used when there is no chlorinator or timer and includes up to 4 separate timers with individual speed options This is ideal for when you want to run your pool pump a...

Page 12: ...tton to put it into run mode this will start the pump When the chlorinator timer turns off the CLEVER POOL will store the speed and resume at that speed when switched on again To stop the pump simply press the RUN STOP button again 3 Back Wash mode In stop mode press the SET RESET button once The display will now show MANUAL LOW RPM and the speed in rpm 12 ...

Page 13: ...Press the BACKWASH button The display will now show backwash and the rpm Press the RUN STOP button to put it into on mode this will start the pump 13 ...

Page 14: ...UN STOP button to stop the pump 4 1 Current time In stop and Auto Mode Press UP and Down button to set Current time Press the SET RESET button to step over from hours to minutes The display will then flash the minutes digits 14 ...

Page 15: ...de timer and Speed setting In stop mode press the SET RESET button The display should show CURRENT TIME START TIME STOP TIME and the stored time with hours digits flashing This is the start time for AUTO MODE 1 Press the SET RESET button to step over from hours to minutes and from Start Time to Stop time Press the up or down button to select the hours 15 ...

Page 16: ...ess the SET RESET button to store the speed and step over to AUTO MODE 2 The display should show CURRENT TIME START TIME STOP TIME and the stored time with hours digits flashing This is the start time for AUTO MODE 2 Repeat steps above to set speed start and stop times for AUTO MODE 2 3 and 4 Pressing the SET RESET button after selecting the speed for Auto mode 4 will finalize the timer settings T...

Page 17: ...eed settings of the remaining TIMERS ensuring all start and stop times are set to zero s or to the same time period Please note all settings for AUTO MODE 1 to 4 will be retained in the event of power loss After all timers have been set The CLEVER POOL will then start and stop the pump at set times and speeds 17 ...

Page 18: ... RPM setting Showing all parameters Parameter setting or re set system Manually control pump run or stop 4 1 BUTTON AND FUCNTION EXPLANATION Explanation Power supply connected or disconnected Pump on or off Increase the parameter Decrease the parameter Pump motor RPM setting Pump motor RPM setting Dial switch S1 Frequency option N stands for 50Hz 2 stands for 60Hz If three phase motor runs in anti...

Reviews: