In stop mode the display will now show MANUAL, LOW RPM and the speed in rpm.
6.A GFCI device must be used in the system.
7.Check if the power supply frequence is the same as CLEVER-POOL, if no please move the dial-switch for option.
8.If all connection is correct,run with no load. If it is a three-phase pump. Please check the motor rotation direction, you
can choose the wire connection between UV,WV or WU, you can also use dial-switch for option.
3.3.2 PROGRAMMING GUIDE
1.The Clever-Pool has two running modes
:
Manual mode and Auto mode.
5.Check if the contral panel is well closed.
1.1 Manual mode is used when you are connecting to a pool chlorinator or timer. The system time settings are not
required to run in this mode.
1.2 Auto mode is used when there is no chlorinator or timer and includes up to 4 separate timers with individual speed
options.This is ideal for when you want to run your pool pump at different times and speeds to take advantage of the different
electrical consumption.
2. Manual mode
1.3 In stop and manual mode press the SET/RESET button once to switch to Auto Mode. In stop and Auto mode press
the RUN/STOP button to switch to Manual Mode.
3. INSTALLATION AND FUNCTION EXPLANATION
- 11 -