Operation Guide
Indication module registration (i95 and i95 ECO)
You may register the indication module (sold separately) to make
operation of the immobilizer more convenient. To do that, switch
the immobilizer to the device registration mode. Then, perform the
following actions:
1) Connect power to the indication module.
2) Wait until the connection monitoring is over (10 seconds before
the LED stops blinking).
3) Press and hold the indication module button for at least 3
seconds, then release it.
4) If the indication module has been registered successfully, you
will see the LED flash in green. In case of a registration error
(i.e., if there is no locking module in the device registration
mode), the LED will flash in red.
5) Turn off the ignition to exit the device registration mode.
The immobilizer only supports one indication module.
53
Module button
Registration
confirmation
Module power supply
Re-energize the indication module
Module LED
Locking module
N times
In device registration mode
Audible signal
> 3 sec
Blinks
for 10 sec
Once
Once