i95 LUX, i95, i95 ECO
Specifications
Parameter
Locking module
Indication module
Label
Frequency range of radio
control signals, MHz
2405...2480
Type of control code
Dialog
Maximum operating radius
of immobilizer components,
m
10*
Power voltage, V
9...16
2.0...3.3
Current consumption when
ignition is OFF, mA
6.6 (i95 LUX,
i95) 2.4 (i95
ECO)
–
Current consumption when
ignition is ON, mA
6.8**
0.2
–
Permissible switching
current via relay contacts, A
10
–
Permissible switching
current at lock control
outputs, A
20
–
Operating temperature
range, °C
-40...+125
-40...+85
-20...+70
Battery type
–
CR2025,
CR2032
Battery lifetime, months
12
Dimensions, mm
94 × 24 ×
13 | 41 × 28 × 9
53 × 26 × 7
* – depends on the immobilizer components layout
** – when the locking is OFF
Label coverage may be reduced depending on the installation
location of the system components
14