GENERAL SAFETY INFORMATION
This equipment is designed and sold for commercial use only, and is intended for use by personnel
trained and experienced in its operation. This is not sold for consumer use in and around the home
nor for use directly by the general public in food service locations.
Before using your new equipment, read and understand all the instructions and labels associated
with the unit prior to putting it into operation. Make sure all people associated with its use understand
the units operation and safety before they use the unit.
GENERAL INSTALLATION INFORMATION
The unit is shipped fully assembled and ready to plug into a standard outlet specified for its voltage
and amp draw. If improper electrical supply can be determined through troubleshooting, contact
a qualified electrician prior to using the unit. Removal or replacement of the power cord or plug will
void the warranty. Should you require assistance, contact your local authorized service agent for any
service or required maintenance.
Level unit using the adjustable feet under the unit (there is approximately 0.5 (1/2) inch of adjustment).
Allow enough space around the toaster for adequate ventilation. It is recommended that you leave at
least a one (1) inch gap on each side as well as at least a two (2) inch gap on the top. Do not operate
the unit without the crumb tray properly positioned. If operated improperly, overheating and poor
toasting may occur.
Before using the unit for the first time, ensure to clean the toaster properly. Refer to the Cleaning
Procedure document for cleaning instructions.
ELECTRICAL CONNECTION
Before making any electrical connection to this unit, check that the power supply is adequate for the
voltage, amperage, and requirements stated on the rating plate. This unit will require a NEMA L6-30R
receptacle. Make certain to disconnect the unit from the power source before installing or removing
any parts. Be absolutely sure that the ground connection for the receptacle is properly wired. Do not
connect equipment to power without proper ground connections. Improper grounding may result in
personal injury or fatality.
DO NOT CUT OR REMOVE THE PLUG OR
ELECTRICAL REQUIREMENTS
GROUNDING PRONG FROM THE PLUG.
30 amps, 208/240 volts, and a NEMA
CONNECT/PLUG UNIT INTO DEDICATED
L6-30R receptacle are required.
AC LINE ONLY SPECIFIED ON THE DATA
PLATE OF THE UNIT.
DO NOT IMMERSE OR LET THE UNIT STAND
IN WATER.
DO NOT HOSE DOWN THE UNIT OR THE
TABLE/COUNTER IF THE UNIT IS ON THE
TABLE/COUNTER.
KEEP AWAY FROM RUNNING WATER.