background image

9

VII. Testing

1. Examination before use

A. Check installation of the whole apparatus and pipeline connections according to the relevant plan.
B. Check the electrical connection according to the relevant diagram, check earth connection.
C. Check that the equipment’s main switch is switched-off.
D. Check the adjusted temperature.
E. Check the supply and out

fl

 ow of air.

2. Trial

A. The user must “start the pump before the equipment and switch off the equipment before the pump”, 

otherwise the equipment will be damaged.

B. The user must start the pump and check that there are no leakages in the water system; then adjust the 

temperature on the thermostat and switch the equipment on.

C. The pool heater is equipped with a guard in the form of a delayed start function; when starting the equip-

ment, the ventilator starts 1 minute before the compressor.

D. After starting the heater, check that the equipment does not make excessive noise during operation.

VIII. Safety precautions

1. Warning

A.  Adjust to a suitable temperature to give a pleasant water temperature; avoid over- or under-heated water.
B. Do not block air supply or out

fl

 ow area with objects which could obstruct the air 

fl

 ow, otherwise the 

heater’s performance will decrease or it could even switch off.

C. Do not insert hands into the heat pump’s out

fl

 ow and do not remove the ventilator mesh. It could cause 

injury.

D. If anything unusual occurs during operation, such as noise, smell, smoke or electrical leak, please switch 

the equipment off immediately and contact the local seller. Do not try to eliminate the fault yourself.

E. To avoid 

fi

 re, do not use or store the equipment near to 

fl

 ammable liquids or gases such as thinner, paint 

or fuel.

F. For optimal heating effects, install a heat insulating material on the pipes between the pool and the 

heater. During operation of the heater, cover the pool with a heat insulating cover.

G. Connecting piping between the heater and the pool must be 

10 m, otherwise the heating performance 

cannot be guaranteed.

H. Equipment in this range is most effective at temper15°C to +25°C.

2. Safety

A. Please keep the main on-switch out of reach of children
B. If there is a power failure during operation, the heater will switch on automatically once the power is res-

tored. Therefore, please switch the heat off during a power failure and after power is restored, re-adjust 
the temperature. 

C. During a thunderstorm, please switch off the power supply, to protect the equipment from damage by 

lightning.

D. During long-term non-use, disconnect power and drain water from the equipment by turning on the tap 

in the supply pipeline.

EN

Summary of Contents for THP05

Page 1: ...HEATING PUMP FOR SWIMMING POOLS THP05 THP30s INSTALLATION AND USER MANUAL EN ...

Page 2: ...ons 8 VII Testing 10 VIII Safety precautions 10 IX Maintenance 11 X Solving common malfunctions 11 Thank you for choosing our product and trusting our company To ensure that using this product brings you joy please read the instructions carefully and follow the user manual exactly before use to prevent equipment damage or unnecessary injuries EN ...

Page 3: ...HP23s THP30s Input in kW 0 7 0 93 1 4 1 8 2 4 3 7 3 7 4 5 Heating performance in kW 5 6 9 12 16 23 23 30 Efficiency 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 Infeed for one phase 220 240V 50Hz 3N 380V 50Hz Rated current Max cur rent in A 4 6 6 4 4 6 6 4 6 4 8 2 8 2 11 10 9 14 1 17 5 26 5 5 6 8 5 6 8 9 5 Sound dB A 48 48 48 48 50 56 56 58 Net weight Gross weight in kg 45 50 45 50 52 57 65 70 85 93 102 110 10...

Page 4: ...adjustment of the equipment On the grounds of continuous improvement product parameters may change without previous notice Model A B C D E F G H THP05 330 580 285 350 930 200 83 550 THP06 330 580 285 350 930 200 83 550 THP09 330 580 285 350 930 200 83 550 THP12 330 650 300 350 1000 280 83 630 THP16 330 650 300 350 1000 280 83 630 THP23 438 770 425 470 1120 350 83 950 THP30S 438 810 425 470 1180 60...

Page 5: ...ng diagram serves only as an illustration pipeline configuration is only referential Signal cable Diagram of pool heating piping Drai nage Outflow of condensate Water into the pool Water treatment apparatus Inflow Pump Inflow of water into the pool Filter tank Mains supply EN ...

Page 6: ...5 15 15 20 25 40 15 30 Mains supply mm2 3x2 5 3x2 5 3x2 5 3x2 5 3x4 3x6 5x2 5 5x4 Signal cable mm2 3x0 5 3x0 5 3x0 5 3x0 5 3x0 5 3x0 5 3x0 5 3x0 5 Note The information above is for a mains cable of 10 m If the mains cable is 10 m the conductor diameter must be increased The signal cable can be a maximum of 50m long Power supply Circuit breaker fuse secured by the customer Mains supply Pool termina...

Page 7: ...rt height 10 m 5 Once the equipment is operating condensate will leak from the lower part Give attention to this oc currence Insert nozzle accessory into the opening and secure well Then attach the condensate drainage tube B Electrical connection 1 Connect equipment to corresponding mains The voltage must correspond with the product s specified voltage 2 Earth the equipment correctly 3 Electrical ...

Page 8: ... the timer is switched on press the button When the pilot light turns on and begins to flash press the button again to adjust hours Adjust the value with the button and Before the time stops flashing press the button for adjusting minutes Adjust the value with the button and After adjustment press the button TIMER ON and water temperature will be displayed After 30 seconds the regulator display re...

Page 9: ...ance will decrease or it could even switch off C Do not insert hands into the heat pump s outflow and do not remove the ventilator mesh It could cause injury D If anything unusual occurs during operation such as noise smell smoke or electrical leak please switch the equipment off immediately and contact the local seller Do not try to eliminate the fault yourself E To avoid fire do not use or store...

Page 10: ...bstruction Protection in the form of 3 minute time delay Wait Adjusted temperature is too low Increase the adjusted temperature correspondingly If the above shown malfunctions cannot be solved please contact a specialist and state the equipment model and give a detailed description of the malfunction Warning To prevent potential injuries do not take apart or repair the pool heater yourself Malfunc...

Page 11: ...ation after service life expiring Ensure ecological liquidation by specialized firm at products service life expiring Claims and service Complains and claims are proceeded according to proper law about consumer protection In the event of inquest irremovable mistakes will turn on his supplier Date Printing mistakes reserved Your seller EN ...