background image

8

                CLOCK     

                   TIME SWITCHED ON     

    TIME SWITCHED OFF

    

 

          AUTO/EH        

                           COOLING    

 

               HEATING

1. Operating display

A. The display shows the time when the equipment is off
B. The display shows water temperature in the pool when the equipment is off

2. Adjusting water temperature

A. This function is accessible regardless of whether the equipment is off or on.
B.  To adjust the water temperature, press the button        or        . The temperature will 

fl

 ash on the regula-

tor. Press the button to adjust to the required water temperature        or        .

C. After 5 seconds, the regulator display returns to its normal mode.

3. Adjusting time

A. This function is accessible regardless of whether the equipment is off or on.
B. To adjust the time, press the button           . When the time on screen begins to 

fl

 ash, press the button           

again to adjust hours. Adjust the value with the button        and        . Before the time stops 

fl

 ashing, press 

the button           for adjusting minutes. Adjust the value with the button        and        . After adjustment, 
press the button           and water temperature will be displayed. After 30 seconds, the regulator display 
returns to its normal mode.

4. Adjusting time of switching on and off of the timer

A. To adjust the time that the timer is switched on, press the button           . When the pilot light turns on 

and begins to 

fl

 ash, press the button           again to adjust hours. Adjust the value with the button

        and        . Before the time stops 

fl

 ashing, press the button           for adjusting minutes. Adjust 

the value with the button        and        . After adjustment, press the button “TIMER ON” and water 
temperature will be displayed. After 30 seconds, the regulator display returns to its normal mode.

B. To adjust the time that the timer is switched off, press the button           . When the pilot light turns on 

and begins to 

fl

 ash, press the button           again to adjust hours. Adjust the value with the button                

        and        Before the time stops 

fl

 ashing, press the button           for adjusting minutes. Adjust the 

value with the button        and        . After adjustment, press the button           and water temperature will 
be displayed. After 30 seconds, the regulator display returns to its normal mode.

C. Cancelling the adjusted time of switching on and off of the timer. To cancel the adjusted time of 

switching on and off of the timer, press the button           or           . When the displayed information 
starts to 

fl

 ash, press the button           . When the timer pilot light switches off and water temperature is 

shown on the display, the adjusted time of switching on and off of the timer has been cancelled. After 
30 seconds, the regulator display returns to its normal mode.

1

1

1

0

0

1

0

0

0

0

EN

Summary of Contents for THP05

Page 1: ...HEATING PUMP FOR SWIMMING POOLS THP05 THP30s INSTALLATION AND USER MANUAL EN ...

Page 2: ...ons 8 VII Testing 10 VIII Safety precautions 10 IX Maintenance 11 X Solving common malfunctions 11 Thank you for choosing our product and trusting our company To ensure that using this product brings you joy please read the instructions carefully and follow the user manual exactly before use to prevent equipment damage or unnecessary injuries EN ...

Page 3: ...HP23s THP30s Input in kW 0 7 0 93 1 4 1 8 2 4 3 7 3 7 4 5 Heating performance in kW 5 6 9 12 16 23 23 30 Efficiency 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 Infeed for one phase 220 240V 50Hz 3N 380V 50Hz Rated current Max cur rent in A 4 6 6 4 4 6 6 4 6 4 8 2 8 2 11 10 9 14 1 17 5 26 5 5 6 8 5 6 8 9 5 Sound dB A 48 48 48 48 50 56 56 58 Net weight Gross weight in kg 45 50 45 50 52 57 65 70 85 93 102 110 10...

Page 4: ...adjustment of the equipment On the grounds of continuous improvement product parameters may change without previous notice Model A B C D E F G H THP05 330 580 285 350 930 200 83 550 THP06 330 580 285 350 930 200 83 550 THP09 330 580 285 350 930 200 83 550 THP12 330 650 300 350 1000 280 83 630 THP16 330 650 300 350 1000 280 83 630 THP23 438 770 425 470 1120 350 83 950 THP30S 438 810 425 470 1180 60...

Page 5: ...ng diagram serves only as an illustration pipeline configuration is only referential Signal cable Diagram of pool heating piping Drai nage Outflow of condensate Water into the pool Water treatment apparatus Inflow Pump Inflow of water into the pool Filter tank Mains supply EN ...

Page 6: ...5 15 15 20 25 40 15 30 Mains supply mm2 3x2 5 3x2 5 3x2 5 3x2 5 3x4 3x6 5x2 5 5x4 Signal cable mm2 3x0 5 3x0 5 3x0 5 3x0 5 3x0 5 3x0 5 3x0 5 3x0 5 Note The information above is for a mains cable of 10 m If the mains cable is 10 m the conductor diameter must be increased The signal cable can be a maximum of 50m long Power supply Circuit breaker fuse secured by the customer Mains supply Pool termina...

Page 7: ...rt height 10 m 5 Once the equipment is operating condensate will leak from the lower part Give attention to this oc currence Insert nozzle accessory into the opening and secure well Then attach the condensate drainage tube B Electrical connection 1 Connect equipment to corresponding mains The voltage must correspond with the product s specified voltage 2 Earth the equipment correctly 3 Electrical ...

Page 8: ... the timer is switched on press the button When the pilot light turns on and begins to flash press the button again to adjust hours Adjust the value with the button and Before the time stops flashing press the button for adjusting minutes Adjust the value with the button and After adjustment press the button TIMER ON and water temperature will be displayed After 30 seconds the regulator display re...

Page 9: ...ance will decrease or it could even switch off C Do not insert hands into the heat pump s outflow and do not remove the ventilator mesh It could cause injury D If anything unusual occurs during operation such as noise smell smoke or electrical leak please switch the equipment off immediately and contact the local seller Do not try to eliminate the fault yourself E To avoid fire do not use or store...

Page 10: ...bstruction Protection in the form of 3 minute time delay Wait Adjusted temperature is too low Increase the adjusted temperature correspondingly If the above shown malfunctions cannot be solved please contact a specialist and state the equipment model and give a detailed description of the malfunction Warning To prevent potential injuries do not take apart or repair the pool heater yourself Malfunc...

Page 11: ...ation after service life expiring Ensure ecological liquidation by specialized firm at products service life expiring Claims and service Complains and claims are proceeded according to proper law about consumer protection In the event of inquest irremovable mistakes will turn on his supplier Date Printing mistakes reserved Your seller EN ...

Reviews: