3.  Installation instructions and requirements

Pool heating must be installed by a skilled team. Users must not install it independently because it could 
cause injury, or damage to the equipment. 

A.  Installation

1) Pool heating must be installed in a place with good ventilation;
2) The frame must be prepared with screws (M10) into the concrete base or brackets. The concrete base 
must be strong and anchored. The bracket must be strong with an anticorrosive treatment.
3) Do not block the in

fl

 ow or out

fl

 ow area with articles which would obstruct the 

fl

 ow of air. There must 

not be any obstruction within 50cm behind the main equipment; otherwise, heating performance will be 
decreased or absent.
4) The equipment requires a pump attachment (supplied by the customer). Recommended pump speci

fi

 ca-

tion: 

fl

 ow: see technical parameters, max. transport height 

10 m;

5) Once the equipment is operating, condensate will leak from the lower part. Give attention to this oc-
currence. Insert nozzle (accessory) into the opening and secure well. Then attach the condensate drainage 
tube.

B  Electrical connection

1) Connect equipment to corresponding mains. The voltage must correspond with the product’s speci

fi

 ed 

voltage.
2) Earth the equipment correctly
3) Electrical connection must be carried out by a professional technician and according to the connection 
diagram. 
4) Install protection against leakage current according to local regulations (leakage current 

 30 mA).

5) The mains supply and signal cable must be arranged systematically and logically, so that cables do not 
interfere with each other.

C.  After completing all connections and repeated inspection, switch the equipment on.

VI. Operating instructions

Picture of the button arrangement

Setting up water 

temperature and time

Timer inspection 

Timer switched on On 

On / Off

Clock

Ti

m

er

switched-of

f

Ti

m

er

 

pilot light

Heating/cooling 

indicator

EN

Summary of Contents for THP05

Page 1: ...HEATING PUMP FOR SWIMMING POOLS THP05 THP30s INSTALLATION AND USER MANUAL EN ...

Page 2: ...ons 8 VII Testing 10 VIII Safety precautions 10 IX Maintenance 11 X Solving common malfunctions 11 Thank you for choosing our product and trusting our company To ensure that using this product brings you joy please read the instructions carefully and follow the user manual exactly before use to prevent equipment damage or unnecessary injuries EN ...

Page 3: ...HP23s THP30s Input in kW 0 7 0 93 1 4 1 8 2 4 3 7 3 7 4 5 Heating performance in kW 5 6 9 12 16 23 23 30 Efficiency 6 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 Infeed for one phase 220 240V 50Hz 3N 380V 50Hz Rated current Max cur rent in A 4 6 6 4 4 6 6 4 6 4 8 2 8 2 11 10 9 14 1 17 5 26 5 5 6 8 5 6 8 9 5 Sound dB A 48 48 48 48 50 56 56 58 Net weight Gross weight in kg 45 50 45 50 52 57 65 70 85 93 102 110 10...

Page 4: ...adjustment of the equipment On the grounds of continuous improvement product parameters may change without previous notice Model A B C D E F G H THP05 330 580 285 350 930 200 83 550 THP06 330 580 285 350 930 200 83 550 THP09 330 580 285 350 930 200 83 550 THP12 330 650 300 350 1000 280 83 630 THP16 330 650 300 350 1000 280 83 630 THP23 438 770 425 470 1120 350 83 950 THP30S 438 810 425 470 1180 60...

Page 5: ...ng diagram serves only as an illustration pipeline configuration is only referential Signal cable Diagram of pool heating piping Drai nage Outflow of condensate Water into the pool Water treatment apparatus Inflow Pump Inflow of water into the pool Filter tank Mains supply EN ...

Page 6: ...5 15 15 20 25 40 15 30 Mains supply mm2 3x2 5 3x2 5 3x2 5 3x2 5 3x4 3x6 5x2 5 5x4 Signal cable mm2 3x0 5 3x0 5 3x0 5 3x0 5 3x0 5 3x0 5 3x0 5 3x0 5 Note The information above is for a mains cable of 10 m If the mains cable is 10 m the conductor diameter must be increased The signal cable can be a maximum of 50m long Power supply Circuit breaker fuse secured by the customer Mains supply Pool termina...

Page 7: ...rt height 10 m 5 Once the equipment is operating condensate will leak from the lower part Give attention to this oc currence Insert nozzle accessory into the opening and secure well Then attach the condensate drainage tube B Electrical connection 1 Connect equipment to corresponding mains The voltage must correspond with the product s specified voltage 2 Earth the equipment correctly 3 Electrical ...

Page 8: ... the timer is switched on press the button When the pilot light turns on and begins to flash press the button again to adjust hours Adjust the value with the button and Before the time stops flashing press the button for adjusting minutes Adjust the value with the button and After adjustment press the button TIMER ON and water temperature will be displayed After 30 seconds the regulator display re...

Page 9: ...ance will decrease or it could even switch off C Do not insert hands into the heat pump s outflow and do not remove the ventilator mesh It could cause injury D If anything unusual occurs during operation such as noise smell smoke or electrical leak please switch the equipment off immediately and contact the local seller Do not try to eliminate the fault yourself E To avoid fire do not use or store...

Page 10: ...bstruction Protection in the form of 3 minute time delay Wait Adjusted temperature is too low Increase the adjusted temperature correspondingly If the above shown malfunctions cannot be solved please contact a specialist and state the equipment model and give a detailed description of the malfunction Warning To prevent potential injuries do not take apart or repair the pool heater yourself Malfunc...

Page 11: ...ation after service life expiring Ensure ecological liquidation by specialized firm at products service life expiring Claims and service Complains and claims are proceeded according to proper law about consumer protection In the event of inquest irremovable mistakes will turn on his supplier Date Printing mistakes reserved Your seller EN ...

Reviews: