-10-
Programming (CONT'D)
Pattern Cycling of Simultaneous Functions
This section is
OPTIONAL
. ‘Pattern Cycling of Simultaneous Functions’ refers to how the
light reacts if you activate more than one function at the same time.
This light is programmed such that when you activate one of the Traffic Directing patterns
(Left, Right, or Center-Out) at the same time as one of the Warning patterns (Level 1
Flashing, Level 2 Flashing, or TD Warn) they will alternate with the bar producing 3 traffic
directing cycles, then 1 Warning cycle, and repeat (ex: Left, Left, Left, Warn, Left, Left, Left,
Warn, etc.).
If you activate TD Warn with either Level 1 or Level 2 Flashing:
If Level 1 or 2 is pattern 1-16:
TD Warn lights alternate the Level 1 or 2 Pattern with the
Level 1 or 2 lights.
If Level 1 or 2 is pattern 17-31:
TD Warn Lights go into a random Pattern while Level 1 or
Level 2 lights flash in their programmed pattern
(page 8)
.
You may skip the rest of this section if the above settings are acceptable.
Traffic Director Cycle Count
refers to the number times the Traffic Directing Pattern
(Right, Left, Center-Out) will repeat before alternating to the Warn/Flashing Pattern. It is
defaulted to 3.
Warn Cycle Count
refers to the number times the Level 1 Flashing, Level 2 Flashing, or TD
Warn pattern will repeat before alternating to the Traffic Directing Pattern (this also applies if
you activate Level 1 or 2 and the TD Warn). It is defaulted to Off (or 0). (Note: if OFF,
pattern runs once when cycling with Traffic Director).
1. Flip the Program Mode switch onto the ON position (DOWN in the diagram on the
previous page).
2. Connect the Red wire to power and the Black wire to Ground.
3. Program the
Traffic Director Cycle Count
:
A. Activate the Left function by connecting the Green w/Yellow wire to +12VDC.
(Please note that the Left, Right, and Center-Out will all have the same Cycle Count
and can be programmed using any one of those functions.)
One of the heads (or none) will illuminate indicating what the current
Traffic
Director Cycle Count
is.
Ex: If no heads are lit, the feature is off. (Default setting Warning Patterns)
If Head 1 is lit, that mode is programmed to cycle 1 time.
If Head 2 is lit, that mode is programmed to cycle 2 times.
If Head 3 is lit, that mode is programmed to cycle 3 times (Default setting
for Traffic Director Patterns)
and so on through Head 10.
B. Touch and release the Green w/Red wire to +12VDC to scroll through the different
Cycle Counts.
4. Repeat step 3 using the White w/Brown wire to program the
Warn Cycle Count
.
(Please
note that Level 1 Flashing, Level 2 Flashing, and TD Warn will all have the same Cycle
Count and can be programmed using any one of those functions.)
5. Disconnect all wires and flip the corresponding DIP switch out of Programming Mode.