35 of 222 pages
Operating and service manual
Value:
“-“ if not done yet. “RUN” if still running test. “PASS” if test finished successfully. “FAIL” if the test
failed. “ABORT” if the test was aborted by the user. See specific description for alarm 820 - 821 in
Test alarms
p.154
T11 Test result: 80 Compressor (80 Compressor)
Function:
Shows the status of the test of the compressor.
Value:
“-“ if not done yet.
“RUN” if still running test.
“PASS” if test finished successfully.
“FAIL” if the test failed.
“ABORT” if the test was aborted by the user. See specific description for alarm 845 and 846 in
Test alarms
p.158
T12 Test result: 90 FT status (90 FT status)
Function:
Shows the status of the function test.
Value:
“-“ if not done yet. “RUN” if still running test. “PASS” if test finished successfully. “FAIL” if the test
failed. “ABORT” if the test was aborted by the user.
T13 Test result: 100 Temperature set point 5°C (100 T set 5°C)
Function:
Shows the status of the performance test with temperature set point of 5°C (41°F)
Value:
“-“ if not done yet. “RUN” if still running test. “PASS” if test finished successfully. “FAIL” if the test
failed. “ABORT” if the test was aborted by the user. See specific description for alarm 855 in
Test
alarms
p.160
T14 Test result: 110 Temperature set point 0°C (110 T set 0°C)
Function:
Shows the status of the performance test with temperature set point of 0°C (32°F).
Value:
“-“ if not done yet. “RUN” if still running test. “PASS” if test finished successfully. “FAIL” if the test
failed. “ABORT” if the test was aborted by the user. See specific description for alarm 860 in
Test
alarms
p.161
T15 Test result: 111 Hold temperature at 0°C (111 Hold 0°C)
Function:
Shows the status of the performance test with holding temperature set point of 0°C (32°F).
Value:
“-“ if not done yet. “RUN” if still running test. “PASS” if test finished successfully. “FAIL” if the test
failed. “ABORT” if the test was aborted by the user. See specific description for alarm 860 in
Test
alarms
p.161
T16 Test result: 120 Temperature set point -18°C
(120 T set -18°C)
Function:
Shows the status of the performance test with temperature set point of -18°C (-0.4°F).
Value:
“-“ if not done yet. “RUN” if still running test. “PASS” if test finished successfully. “FAIL” if the test
failed. “ABORT” if the test was aborted by the user. See specific description for alarm 870 in
Test
alarms
p.161
T17 Test result: 130 Testing of defrost (130 Defrost)
Function:
Shows the status of the performance test of defrost.