View A
Door lock assy
M8 fixing hex hd.
M8 fixing button hd.
Rubber 'P' section
Horizontal door member
10 HALF HEIGHT GATE
10.1 Half height gate assembly
Before fitting gate frame please refer to 2.1 for corner upright preparation.
Once in position secure horizontal door member in the same manor as 2.2.
Fix hinge side using 2 x M8 button head screws through slots, glue ‘P’ section over slots,
ensuring front edge of ‘P’ section is flush with door frame.
On the slam side remove door lock assy. Fix back using 2 x M8 hex head screws. Refit door
lock once wiring is complete.
If after fitting gate frame, holes are visible on corner upright, use blanking plugs provide.