SRP 6570 User
Manual ◄ 13
Important
Switching-Off the Engine
OPERATION
Attention
Danger
DO NOT SWITCH-OFF THE ENGINE WHILE UN-
DER FULL LOAD AND DO NOT USE THE DE-
COMPRESSOR LEVER.
• Allow the engine to run a short while on idling.
• Set the speed lever to stop. Additionally by electrostart:
• Turn the ignition key to «0» position. (The indicator lamps
should go out.)
The horn will sound if the ignition key is not re-
turned to the «0» position; a risk of total battery
discharge exists.
• Remove the key.
At the end of a working day or on a break protect
the key from unauthorised access.
Automatic engine cut-off
Machines are equipped with a safety engine cut-off.
The engine switches-off automatically if
• the oil pressure is too low
• the lubrication oil is unstable as a result of
• excessively high oil temperature
• incorrect baisc viscosity
• dilution of the oil by fuel or water
• the lubricating oil filter is blocked
• a leakage in the oil relief valve
• leakages in pipes and seals
• the oil pumps and bearings are worn.
If the oil level is too low or the machine is tilted
too much, it can lead to a mixture of air/oil and
thus to a loss of viscosity.
Attention
If the engine cuts-out because the supply of lubricating oil is
insufficient, proceed as follows :
• Locate the fault and have it rectified.
• Press the lever few seconds.
• Start the engine.
Air filter maintenance indicator
The motors are equipped with a maintenance indicator for
air filters. In case of pollution of the filter element the rubber
bellow contracts by underpressure.
In this case, switch-off the motor and clean or replace the
air-filter.