18 ► SRP 6570
User Manual
Maintenance Machine
MAINTENANCE
Cleaning
Clean the machine thoroughly daily.
Attention
Tightening Torque
After cleaning
– all cables, hoses, connections and connectors are
to be checked for leakage, loose connections,
chafing points and other damage.
– Detected faults are to be eliminated immediately.
No combustible or aggressive materials are to be
used for cleaning.
Strength classes for screws with untreated, non-lubricated
surface.
The values result in 90% utilisation of the apparent yielding
point at a friction coefficient µges= 0.14.
Tightening torques are checked for correctness using
torque wrenches.
When using lubricant MoS2, the specified values do not
apply.
Renew self-locking nuts after each removal.
Important
With vibrating machines, it is important to check all
screwed connections for tightness at regular intervals.
Observe tightening torques.
Screwed Connections
Changing rubber buffer
Inspect the rubber buffers for cracks and chipping as well as
tightness and immediately replace if damaged.
Exciter: Oil change / Oil level
Check / change exciter oil when its warm.
The venting screw (3) must always be unscrewed
first when checking the oil level or changing the
oil.
Important
• Unscrew venting screw (3), oil filling plug (1) and oil drain
plug (2).
• Drain-off old oil.
Care is to be taken with the draining of hot oil
: danger of scalding!
Danger
Collect oil which has run out or overflowed and
dispose it in an environment friendly manner.
Environment
• Screw-in oil drain screw (2).
• Fill-in new oil through the oil fill hole (1). See lubrication
plan for quantity and quality.
Attention
When the dipstick is screwed in, the optimal
oil level is between the «MIN» and «MAX»
markings.
• Replace oil filling plug (1) and venting screw (3).
• Unscrew oil filling plug (1), check the oil level again and
top off with oil if necessary.
• Replace oil fill plug/dipstick (1).