background image

20  

 

   

Installation and Use 

Error proofing is one of the most important features of the eProFSC controller. Once an application has been set-up, the ePro controls 
the torque applied and discerns between a fastening cycle PASS and the following errors: 

LOW TORQUE or Short Cycle: If the tool has run many cycles and the pulse oil or the air motor needs maintenance, the tool may not
be able to reach torque. Also the operator may be stopping the cycle prior to completion of the fastening to TARGET TQ. This 
sometimes occurs when the operator anticipates the end of cycle and releases the throttle trigger prematurely (before the ePro 
controller has shut-off the tool). If LOW LIMIT GRN ON is chosen in the ADMIN MENU and the operator lets go of the throttle after
the LOW LIMIT has been passed, then a PASS will result, even though TARGET TORQUE has not been achieved. 

HIGH TORQUE: This can occur if the joint conditions change to a harder type joint than what was the original or the PSI has been
adjusted to increase the speed of the tool beyond what can be controlled consistently on the application. This can also occur if the 
CAL VALUE is incorrect. 

RE-HIT: This occurs whenever the tool is applied to a pre-tightened fastener. This is not a defaulted error condition. It must be set up 
through the MIN PULSE COUNT in the ADMIN MENU. Once set up correctly an NOK will be displayed when the tool is cycled on a 
previously tightened fastener. If a REHIT is accepted, the MIN PULSE COUNT feature should be adjusted. 

MIN PULSE COUNT: If a  MIN number of PULSES is not achieved before TARGET TORQUE is reached, an error will occur. Once set up 
correctly, if a previous tightened fastener or a cross-thread occurs, a NOK will result. The system default is “0” pulse counts, which 
means all rundowns which result in a final torque between LOW LIMIT and HIGH LIMIT will be OK. 

MAX PULSE COUNT: If a strip or cross-thread occurs, this can cause too many pulses and the bad cycle. This error can also occur if 
the pulse pack in the tool is in need of service or failing. 

Slip-off (or cam out): If the socket or screwdriver bit slips off the fastener, the controller will not count the cycle or alarm this 
condition as TQ LOW if the THRESHOLD has not been crossed. 

Short cycle (premature cycle abort): This feature insures that only attempts to tighten fasteners are counted. The controller will not 
count the cycle or alarm this condition as TQ LOW if the THRESHOLD has not been crossed. 

NOTE

: The eProFSC ignores free air running of the tool unless THRESHOLD is crossed. 

Error Proofing OK / NOK 

Normal Operation: Run Mode 

When operating in the RUN mode, the UP/ DOWN keys allow the operator to change between parameter sets, unless the PSET LOCK 
OUT is activated. PSET LOCK OUT is recommended when only one PSET is being utilized. 

Pressing the BACK button clears the batch. The BATCH NOK output fires and turns on the red BATCH LED. 

Pressing and holding the BACK button for 1-2 seconds puts the ePro in “OVER-RIDE” mode. OVER-RIDE means that the system has 
full power 

without 

any torque control or shut-off capabilities. 

The ePro has a two line main display. This shows the final TORQUE, Parameter or PSET, the BATCH or fastener COUNT and the 
BATCH TIMER. BATCH COUNT represents the number of fasteners that the ePro has been programmed to count (per BATCH). LED’s 
will change to GREEN upon reaching an OK or GOOD fastening cycle. Outputs and  CYCLE lights on the tool, if applicable, fire 
automatically. CYCLE lights on the tool can be fired after crossing the LOW LIMIT or when TARGET TORQUE is achieved.  

The BATCH light on the ePro and internal outputs also fire automatically. Running the next cycle clears and resets these lights and 
outputs automatically. By selecting I/O MOMENTARY from the ADMIN MENU will clear the cycle lights and the outputs after 2 
seconds.

에러 프뤼핑은 PSI-C 컨트롤러에서 가장 중요한 기능 중 하나입니다. 일단 장비가 셋업되면, PSI-C는 적용된 토크를 조정 하고 조
임 사이클 통과와 다음의 에러에서 구별 됩니다.

Low 토크나 Short Cycle : 툴을 너무 오래 사용하고 또 펄스 오일이나 에어 모터가 유지 보수를 필요로 하게 되고, 작업시 목표 토크
값에 도달하지 않을 것 입니다. 또한 작업자가 조임작업이 끝나기 전에 사이클 완료가 될지 모릅니다. 이러한 경우에 작업자가 작업
이 끝나기 전에 트리거를 미리 놓는 현상이 일어나곤 합니다. Low Limit GRN ON이 ADMIN Menu에서 선택되고 작업자에게 LOW 
LIMIT 통과가 발생되고 있으면, 타겟 토크에 도달 하지 않았음에도 불구하고 PASS는 결과값을 보여줄 것입니다. 

High Torque : High Torque는 조인트의 상태가 원래의 조인트 보다 강한 조인트 타입으로 변경 되거나, PSI가 조절 할 수 있는 속
도 이상으로 조정 되었을때 때 발생됩니다. 이러한 현상은 또한 CAL값이 부정확 할 때에도 발생합니다.

Re-Hit : Re-Hit는 툴이 미리 조여진 조임체에 적용될때는 언제나 발생합니다. 이것은 기본 에러 컨디션은 아니고, Admin Menu
의 Min Pulse Count를 통해 셋업해야 합니다. 일단 정확하게 셋업되면 NOK는 툴이 이전에  조여진 조임체에서 작업될 때 나타날 
것 입니다. Rehit이 받아 들여지면, Min Pulse Count기능은 적용 될 것 입니다.

Max Pulse Count : 스트립이거나 Cross-thread가 발생하면, 이것은 굉장히 많은 pulse와 bad cycle를 야기 합니다. 이러한 에러
는 툴 내의 펄스 팩이 서비스의 필요하거나 실패에 있다면 또한 발생할 것입니다. 

Slip-off(or cam out) : 소켓이나 스크루 드라이버 비트가 조임체에서 미끄러져 빠지면, 컨트롤러는 사이클을 카운트 하지 않거나, 
이러한 상태를 Threshold가 교차되지 않는 다면 TQ LOW로써 경고 할 것 입니다. 

Short Cycle(Premature cycle abort) : 이 기능은 조임체를 조인 시도만 카운트 한다는 것을 보증 합니다. 컨트롤러는 Threshold
가 교차하지 않을 경우에 사이클을 카운트 하지 않거나 TQ LOW로 이 조건을 경고 할 것입니다.

NOTE : PSI-C는 Threshold가 교차되지 않으면 툴의 공회전을 무시 합니다.

Run모드에서 작업할때 UP/DOWN키는 작업자가 파라미터셋을 변경하는 하는 것을 가능하게 합니l다. PSET LOCK OUT가 실행되
지 않는 다면 PSET LOCK OUT는 하나의 PSET이 사용될 때 권장 됩니다. 

배치를 지우기 위해 BACK버튼을 누르세요. BATCH NOK는 fire를 출력하고 빨간색 BATCH LED를 켭니다.

1~2초 동안 BACK버튼을 누르고 있으면 PSI-C는 OVER-RIDE모드가 됩니다. OVER-RIDE는 시스템이 어떠한 토크 컨트롤 없
이 full power를 가지거나 가능 출력을 차단하는 것을 의미 합니다. 

PSI-C는 두줄의 메인 디스플레이를 가집니다. 이것은 최종 토크값, 파라미터나 PSET, Batch나 조임 카운트와 Batch Timer을 보
여 줍니다. Batch Count는 PSI-C가 Batch 하나 하나를 카운트 하기 위해 프로그램된 조임의 숫자를 나타냅니다. LED는 OK나 
GOOD fastening cycle로 도달 했다는 Green색을 나타냅니다.   

19

PSI-C

Min Pulse Count : Pulse의 최소 값은 타겟 토크값이 도하기전에 도달되지 않는다면, 에러가 발생 할 것 입니다. 일단 정확하게 셋
업되면 이전에 조여진 조임이나 Cross-thread가 발생하면 NOK가 결과로 나타날 것 입니다. 시스템 디펄트는 0 펄스 카운트입니
다.

Summary of Contents for PSI-C

Page 1: ...the equipment or described in this manual Stanley Assembly Technologies Applications Productivity Center 5800 Enterprise Court Warren MI 48092 3476 Tel 586 393 1100 Fax 586 393 1200 Toll Free in the US 1 877 787 7830 www stanleyworks com PSI C 0406 THE STANLEY WORKS ALL RIGHTS RESERVED G G G G G G G G G G G G G G G G G G rUzUlUjG 㟬䏭ⷸ㐐GἼ㷐ẠGᴴ G _XTXXG 䊀䆠 G_㵜G W 䝬G ࣜࣜࣜऌऄऋऊँࣶࣜࣜ ࣲࣩࣩࣴࣳࣳ ࣳࣤ堆ࣥࣜࣨࣜंࣽऔࣶࣜࣜ ࣩࣴ...

Page 2: ... Air Supply Requirement 6 Tool Compatibility and Transducer Pulse Tools 7 Layout and Operator Interface 8 Main Menu and Application Programming 9 Parameter Set Up 10 Test 11 Administration Functions 12 Error Proofing OK NOK 13 Normal Operation Run Mode 13 Inputs Outputs I O 14 RJ45 15 Networking 15 Service and Maintenance 15 Troubleshooting and Adjustments 16 2 PSI C ...

Page 3: ...Only allow suitably qualified personnel to install program or maintain this equipment and or system These persons must be knowledgeable of any potential sources of danger and maintenance measures as set out in the Installation Operations and Maintenance manual This product must be transported stored and installed as intended and maintained and operated with care to ensure that the product function...

Page 4: ...he standard configuration utilizes a CE approved power supply that is UL listed It consists of a wall mount 120VAC transformer with a 16VAC 50 Hz at 1 Amp power output Power supplies for other International standards Japan 110 v 50 Hz 1 Amp part 10565 Australia 240 v 50 Hz 1 Amp part 10566 United Kingdom 240 v 50 Hz 1 Amp part 10567 Europe 220 v 50 Hz 1 Amp part 10568 To Avoid Injury Plug power co...

Page 5: ... rated up to 7 amps at 48V AC DC Printer optional Internal Thermal Printer for documentation of cycle data onto individual labels 2 x 4 adhesive backed Serial Port RS 232 port RJ45 connector Interface Dual Line 0 5 LCD backlit 16 character Five button keypad Up Down Enter Menu Back ADMIN Back button Momentary for Batch reset hold down 2 sec for Over ride LED Indicators CYCLE OK NOK Indicators BATC...

Page 6: ...valve and will not allow air flow back thru the lubricator This type is not recommended for use with the ePro FSC The tool air hose cable for the EITP EITM and ESPT series of tools is called the GEMINI The GEMINI air hose includes an integral transducer cable and is available in 3 8 I D coiled or straight and available in many lengths A separate transducer cable is also available Prevent any unnec...

Page 7: ...he torque required If prevailing torque is present then an over sized tool may be required If you desire to utilize any other brand of standard pulse tool Uryu Atlas Copco etc contact your salesperson for a transducer attachment for your tool This allows use of these common tools to be controlled with the PSI C process controller wzpTjG䆮䔎 㦖G G㭒㣪䞲Gぢ ⰢG㞚 G㓺䌶ⰂGwlG䔎 㓺 G䗚㓺䒊ὒG 䢎Gᾦ䢮 㦚GṖ㰧 UG 䞲Gộ㦖G 㔶㦮G 㧒㯞ⰾ...

Page 8: ...45 REMOTE KEYPAD LIGHTS etc 12 24V I O INPUTS OUTPUTS POWER SOCKET ePro URYU option POWER SOCKET STD 3 8 NPT AIR OUTPUT GEMINI HOSE CONNECT I O SCHEMATIC DATA X FER NETWORK SERIAL ETHERNET or DCX PFCS 1 2 NPT AIR INPUT TRANSDUCER CABLE CONNECT GEMINI HOSE PSI C ...

Page 9: ...Installation and Use 9 11 10 20 23 22 4 7 5 19 6 17 9 8 18 13 15 24 27 30 32 1 21 3 34 35 12 33 25 29 28 26 2 31 16 36 37 38 ePro FSC Controller Assembly Assembly Part No 11024 PSI C PSI C ...

Page 10: ...creen Press the ENTER key and the ePro automatically checks and sets the ZERO and MAX values of the transducer connected TARGET TORQUE Enter the target torque of the application by scrolling up or down press ENTER HIGH LIMIT Scroll to set the upper torque specification press ENTER LOW LIMIT Scroll to set the low limit torque specification press ENTER BATCH COUNT Scroll up to set the number of fast...

Page 11: ...LETE CAL TRANSDUCER CHECKING CAL CAL TRANSDUCER CHECKING MAX PARAMETER 1 NOT SETUP SET TARGET TORQUE 50 0 NOM CAL VALUE TQ 75 0 CAL TRANSDUCER CHECKING ZERO CAL TRANSDUCER CHECKING MAX CAL TRANSDUCER COMPLETE SET HI LIMIT TORQUE 57 5 Use the UP DWN arrows to find the parameter set desired Press ENTER to select Default HI LO Limits are set to 15 of Torque Target 11 PSI C PSI C ...

Page 12: ...OPERATION FLOWCHART INITIAL SETUP FSC CONT SET BATCH TIMER SECOND S 4 SET BATCH COUNT COUNT 2 TQ 50 5 PS 2 CT 02 TIMER 004 This is the RUN screen SET LO LIMIT TORQUE 42 5 12 PSI C PSI C CONT ...

Page 13: ... the tool will run until TARGET TQ is achieved MAX PULSE COUNT This sets a maximum allowable PULSE COUNT before the cycle is REJECTED If a strip or cross thread occurs this can help detect the bad cycle It can also detect a failing pulse pack unit Press ENTER and LAST RUN and MAX PULSE CT setting will appear The setting can be tested at this point Watch the screen and run some good and bad cycles ...

Page 14: ...usually 50 60 of the specified final torque Press ENTER Note BATCH COUNT must be programmed for correct sequencing The Run Screen will now show PTQ when running the PRETORQUE or snug torque PRETORQUE all fasteners When PRETORQUE BATCH is finished OK The Run Screen will change to show TQ Final Torque all fasteners Note MIN PULSE COUNT may need to be adjusted to accept final torque while still rejec...

Page 15: ...START 65 START PSI PSI 50 ADMIN MENU START PSI ADMIN MENU DOWNSHIFT DOWNSHIFT TORQUE 50 0 JOINT CONDITION PULSES 0 ADJUST DOWNSHIFT PSI 35 START 50 DYN TQ 0 0 STATIC TQ 0 0 CAL CORRECT CAL 200 0 CONTINUED BELOW PULSE DELAY PULSE S 5 ADMIN MENU PULSE DELAY PRETRIGGER PT 00 0 A 00 0 ADMIN MENU PRETRIGGER ADMIN MENU MAX PULSE COUNT LAST RUN 32 MAX PULSES 200 ADMIN MENU MIN PULSE COUNT LAST RUN 37 MIN...

Page 16: ...0 UP SET DWN CLR ADMIN MENU CYCLE COUNTER CYCLE COUNTER CYCLES 0 ADMIN MENU BATCH COUNT SET BATCH COUNT COUNT 2 SET BATCH TIMER SECOND S 4 ADMIN MENU BATCH TIMER ADMIN MENU LO LIMIT ADJUST LO LIMIT TORQUE 43 2 ADJUST HI LIMIT TORQUE 52 8 ADMIN MENU HI LIMIT CONTINUED BELOW ADMIN MENU CYCLE DELAY SET CYCLE DELAY DELAY 1000 CONTINUED ON NEXT PAGE 16 PSI C PSI C CONT ...

Page 17: ...T ADMIN MENU TIME DATE 03 08 07 01 49 UP SET DWN EXIT SET TIME DATE MONTH 03 SET TIME DATE DAY 08 SET TIME DATE YEAR 07 CONTINUED ON NEXT PAGE ADMIN MENU STATS STATS SAMPLES 10 DATA UP CLR DWN DWNLOAD ADMIN MENU DATA DATA 28 800 8 N 1 DATA DATA CLEARED CONTINUED BELOW 17 PSI C PSI C CONT ...

Page 18: ... TQ 0 0 PRETORQUE THOLD 0 0 PRETORQUE PSI 50 0 ADMIN MENU ADMIN LOCK OFF LEARN ADMIN CODE CODE ADMIN MENU RAMP SPEED MED ADMIN MENU RAMP SPEED HI ADMIN MENU FILTER SET FILTER FREQ FREQ 1150 ADMIN MENU RAMP SPEED LOW UNIT IP ADDRESS 192 ADMIN MENU ETHERNET OPERATION FLOWCHART ADMIN MENU FSC CONT CONTINUED BELOW ADMIN MENU RAMP SPEED OFF 18 PSI C PSI C CONT ...

Page 19: ...OUT is recommended when only one PSET is being utilized Pressing the BACK button clears the batch The BATCH NOK output fires and turns on the red BATCH LED Pressing and holding the BACK button for 1 2 seconds puts the ePro in OVER RIDE mode OVER RIDE means that the system has full power without any torque control or shut off capabilities The ePro has a two line main display This shows the final TO...

Page 20: ...of either polarity I O SCHEMATIC OUTPUTS PIN 1 COMMON PIN 2 CYCLE OK PIN 3 CYCLE NOK PIN 4 BATCH OK PIN 5 BATCH NOK INPUTS PIN 6 DISABLE TOOL PIN 7 BATCH REJECT RESET PIN 8 MANUAL WRENCH ACCEPT PIN 9 PSET BIT 3 BINARY PIN 10 PSET BIT 2 PARAMETER PIN 11 PSET BIT 1 SELECT PIN 12 INPUT COMMON I O CONNECTOR PLUG OPTIONAL PART 11424 BATCH DISABLE BATCH BATCH 12 11 10 9 8 7 6 5 4 3 2 1 0 0 1 PS1 0 1 0 P...

Page 21: ...a Collection and Download If the ePro FSC has the optional DTU Data Transfer Unit part 10771 all parameter sets and rundown data from the last 700 readings per Pset is stored in the memory of the DTU The SigmaSIX Data Transfer Kit part 11556 can be used to download this data to a Microsoft Excel spreadsheet The kit includes the SigmaSIX Data Transfer Software Program and all cables and adapter req...

Page 22: ...led and the ePro is being converted to PFCS communication follow the instructions below PFCS EtherNET network card Remove jumpers from main control board JP1 and JP2 PFCS Serial network card Remove all jumpers from main control board JP1 and install jumpers onto all positions on JP2 Once the Data Collection Cable Assembly is correctly assembled Open the SigmaSIX Data Collection Software Program Se...

Reviews: