Installation and Use 

                                                                                                                                                                                                                                                                                         15 

Administration Functions 

(cont’d)

CYCLE COUNTER: This allows a maintenance cycle counter to be set that will count down from a selectable number of cycles. Once 
this number of cycles is achieved a MAINTENACE REQUIRED screen appears so that normal pulse tool maintenance can be per-
formed. Press Enter and UP/SET, DWN/CLEAR appears. Press UP and CYCLES will appear. Scroll UP to set the number of cycles to 
count. 

BATCH COUNT: Press ENTER to adjust the BATCH COUNT or the total fasteners to be run successfully on the part. Press ENTER and 
scroll UP or DOWN to alter the fastener COUNT per BATCH. 

BATCH TIMER: Press ENTER to adjust the BATCH TIME or the total cycle time for all fasteners to be run successfully on the part. Zero 
is equal to OFF or no timer. Press ENTER and scroll UP or DOWN to alter the number of SECONDS allowed for the BATCH. If all fas-
teners are not successfully tightened in the allotted time, a Batch NOK occurs. 

TARGET TORQUE / HI LIMIT / LOW LIMIT: Adjust the torque target, high or low limit if the specification changes. 

LOW LIMIT GRN ON: Use the ENTER button to toggle ON/OFF whether the green (OK) LED light turns ON after the LOW LIMIT is 
crossed. If OFF is chosen, the green LED will come on when TARGET TQ is achieved. Scroll to the next ADMIN function. Press the 
BACK button to return to the RUN screen. TIME/DATE: Adjust the TIME and DATE accordingly. 

CYCLE DELAY: This setting determines the 

off

 time between the end of one run-down and tool reset for the next cycle. The total 

range of adjustment is between 10 and 1000 counts. This relates to .25 second to 4 seconds of 

off

 time. The default value of 100 will 

keep the tool off for about one half second before allowing the operator to press the trigger for the next fastener. If this is too slow, 
adjust (by using the UP/DWN buttons) the value down to approximately 60-80. Any lower may be too quick and may not allow the 
operator enough time to release the trigger. A higher value causes the tool to reset slower. 

TIME/DATE: Sets TIME and DATE. Press UP to SET. Scroll to change. Press ENTER. Press DOWN to exit. 

STATS: Press ENTER. Scroll UP or DOWN to select SAMPLE SIZE. Press ENTER to view CP, CPK. Press ENTER again to view MEAN, 
RANGE, and press ENTER again to see MIN and MAX readings. Press BACK UP key to EXIT. 

DATA: allows the download of all data stored on optional DTU (Data Transfer Unit). Press ENTER. Press DOWN to download all RS232
serial data through RJ45 serial port. Press UP to CLEAR all DATA. 

I/O (Latched or Momentary): Allows the outputs to be 

latched

 until the next cycle starts, or 

momentary

 which turns the outputs off 2 

seconds after the completion of the cycle. Toggle by pressing ENTER. Scroll UP or DOWN to move to the next option.  

P-SET LOCK OUT: Activating this option locks out the parameter keys from the operator. This prevents the ePro from being switched
to a parameter set that is not set up. Press ENTER to lock and ENTER again to un-lock. Scroll to move on. 

PROGRAM LOCK OUT: Activating this option locks out the program keys from the operator allowing only PSET selection and Batch 
Clear. Press ENTER to lock and ENTER again to un-lock. Scroll to move on to the next option. 

ADMIN LOCK ON/OFF: Initially turning this feature ON will allow the entry of a four button code using the existing four keys in a pro-
grammable order. Once this is done, this programmed button order must be entered every time the ADMIN MENU is accessed 
through the hidden ePro button. Turning this OFF will allow entry to the ADMIN MENU without a four button code. 

FILTER: Sets the FILTER Frequency for the transducer circuit. Default is FREQ=1150. 

EtherNET: Allows entry of the UNIT IP ADDRESS. Scroll UP or DOWN to change. Press ENTER. 

PRETORQUE: Allows the setup of a 

two-step 

fastening procedure. This is used for wheels, cylinder heads or any assembly may  re-

quire a “snug” torque before a “final” torque to compensate for relaxation. Press ENTER. Scroll UP to choose PRETORQUE. This is
usually 50-60% of the specified “final” torque. Press ENTER. Note: BATCH COUNT must be programmed for correct sequencing. The 
“Run Screen” will now show “PTQ” when running the PRETORQUE or “snug” torque. PRETORQUE all fasteners. When PRETORQUE 
BATCH is finished “OK”. The “Run Screen” will change to show “TQ”. Final Torque all fasteners. Note: MIN PULSE COUNT may need 
to be adjusted to accept final torque, while still rejecting a REHIT fastener. 

RAMP SPEED: HIGH, MED, LOW can be chosen to set the RAMP SPEED of the air pressure from the START PSI. The START PSI de-
fault value is 70 PSI. This is to control the rundown speed and prevent torque scatter.  When the tool “runs” a fastener, the PSI is 
RAMPED up to maximum PSI until the TARGET TQ is achieved. The speed at which this PSI is increased is selectable. Toggle with the
ENTER button to choose. Scroll to the next ADMIN function. Press the BACK button to return to the RUN screen. 

CYCLE COUNTER:

이것은 메인터넌스 사이클 카운터를 선택 가능한 수의 사이클로부터로 세어 나갈것인가를 셋팅하는 것을 허용합니

.

이 사이클의 수가 실행되어 지면 노멀 펄스 툴의 메인터넌스가 실행 될 수 있게

,

스크린에

 MAINTENACE REQUIRED

가 나타납니다

.

Enter

키를 누르면

 UP/SET, DWN/CLEAR

가 나타납니다

. UP

키를 누르면 사이클이 나타날 것 입니다

.

사이클 수의 카운트를 설정하기 위

 UP

키를 누르세요

.

BATCH COUNT: BATCH COUNT

를 조정하거나 파트에서 총 조임이 성공적으로 운영되었는지를 알기 위해

 ENTER

키를 누르세요

. ENTER

키를 누르고

 UP

키와

 DOWN

키를 스크롤하여

 BATCH

당 조임 카운트를 바꾸세요

.

BATCH TIMER: BATCH TIME

를 조정하거나 파트에서 모든 조임이 성공적으로 운영되기 위한 총 사이클 타임을 알기 위해

 ENTER

키를

누르세요

.

제로는

 OFF 

또는 타이머가 없는 것과 같습니다

. ENTER

키를 누르고

 BATCH

를 위한 시간의 바꿈을 허용하려면

 UP

키와

 DOWN

키를 스크롤 하세요

.

만일 모든 조임체가 지정된 시간안에 성공적으로 조여지지 않았다면

, Batch NOK

가 나타날 것 입니다

.

TARGET TORQUE / HI LIMIT / LOW LIMIT:

만일 세부 항목이 바뀌면

 target torque, high limit, low limit

을 조정하세요

.

LOW LIMIT GRN ON: LOW LIMIT

이 교차된 후에 녹색의

(OK

) LED

라이트가 켜짐에 관계없이

 ON/OFF

를 바꾸기 위해

 ENTER

키를 사용

하세요

.

만약

 OFF

가 선택되면

, TARGET TQ

가 이뤄질 때 녹색

 LED

가 켜질 것입니다

.

다음

 ADMIN 

기능을 위해 스크롤 하세요

. BACK

키를

누르면 운용 스크린으로 돌아갈 것 입니다

. TIME/DATE

TIME

 DATE

를 조정 하세요

.

CYCLE DELAY:

이 설정은 다음 사이클을 위해 마지막

 1

개의 런다운 데이터와 툴 리셋 사이에

 off time

을 결정합니다

.

조정의 총 범위는

10

 1000 

카운트 사이에 있습니다

.

이것은

 0.25

초에서

 4

초간의

 off time

과 관련이 있습니다

.

초기값

 100

은 작업자가 다음 조임을 위해

트리거를 누르는 것을 허용하기 전에 약

 1.5

초동안 툴을 멈출 것 입니다

.

만일 이것이 너무 느리면 설정값을 대략

 60-80

으로 조정하세

.(UP/DWNO

키를 사용하여

)

낮은 설정은 너무 빠를지도 모르고 툴을 운용 할 작업자에게 충분한 시간을 허용하지 않을지도 모릅니

.

높은 설정값은 툴을 느리게 재설정 할 수 있습니다

.

TIME/DATE: TIME

 DATE

를 셋팅 하세요

. UP

키를 누르면 설정 됩니다

.

스크롤하여 바꾸세요

. ENTER

키를 누르세요

. DOWN

키를 누르

면 돌아 갑니다

.

STATS: ENTER

키를 누르세요

. SAMPLE SIZE

를 선택하기 위해

 UP

키 또는

 DOWN

키를 스크롤 하세요

. CP, CPK

를 보기 위해

 ENTER

키를

누르세요

. ENTER

키를 다시 누르면

 MEAN, RANGE

를 볼 수 있고

,

ENTER

키를 누르면

 MIN

 MAX

의 값을 볼 수 있습니다

. BACK UP

를 누르면 돌아 갑니다

.

DATA:

옵션의

 DTU(DATA Transfer Unit)

는 저장된 모든 데이터의 다운로드를 허용 합니다

. ENTER

키를 누르세요

. RJ45

시리얼 포트를

통해 모든

 RS232 

시리얼 데이터를 다운로드하기 위해

DOWN

키를 누르세요

. UP

키를 누르면 모든 데이터는 지워 집니다

.

I/O (Latched or Momentary):

다음 사이클의 시작까지

 output

을 래치 시키거나 작업 완료 후에 순간적으로

 output

 2

초 동안 정지 시킵

니다

. ENTER

키를 누르면 토글 됩니다

.

다른 옵션으로 이동하기 위해

 UP

키 또는

 DOWN

키를 누르세요

.

P-SET LOCK OUT:

이 옵션은 작업자로부터 파라미터 키로 들어가지 못하게 합니다

.

이것은

 PSI-C

가 셋팅되지 않는 파라미터를 새로 바

꾸게 되는 것을 방지 합니다

. ENTER

키를 누르면 파라미터는 잠기고 다시

 ENTER

키에 누르면 해제 됩니다

.

다음 단계로 가려면 스크롤

하세요

.

PROGRAM LOCK OUT:

이 옵션은 작업자로부터

 PSET 

선택과

 Batch Clear

만을 허락하고 프로그램 키로 들어가지 못하게 합니다

. ENTER

키를 누르면 잠기고

 ENTER

키를 다시 누르면 해제 됩니다

.

다음 옵션으로 가기 위해 스크롤 하세요

.

ADMIN LOCK ON/OFF:

초기에 이 특징을 켜는 것은 프로그램의 명령에서 기존의

 4

개의 키들를 사용하고 있는

 4

개의 버튼 코드의 입장을

허락 할 것입니다

.

이것이 하게 되면,

ADMIN MENU

가 숨겨졌던

 PSI-C

버튼을를 통해 접근 될 때마다

,

이 프로그램 되었던 버튼 명령을

넣어야 합니다

.

이것을 끄게 되면

 4

개의 버튼 코드없이

 ADMIN MENU

에 입장을 허용 할 것 입니다

.

FILTER:

트랜스듀서 회로를 위한

 FILTER Frequency

를 설정합니다

. Default

 FREQ=1150

입니다

.

EtherNET:

본체

IP ADDRESS

의 입장을 허용 합니다

. UP

키 또는

 DOWN

키를 스크롤하여 변경 하세요

. ENTER

키를 누르세요

.

PRETORQUE: two-step

의 조임 과정의 셋팅을 허용 합니다

.

이것은 휠

,

실린더 헤드 또는 어떤 조립이든

 "final" 

토크 전에 응력 완화를 위

한 보정인

 "snug" 

토크가 요구 될때 사용 됩니다

. ENTER

키를 누르세요

. PRETORQUE

를 선택하기 위해

 UP

키를 스크롤 하세요

.

이것은 보

통 설정된

 “final”

토크의

 50-60%

입니다

. ENTER

키를 누르세요

. Note:

올바른 시권스를 위해

 BATCH COUNT

는 프로그램 되어야 합니다

.

PRETORQUE

가 실행되거나

 "snug" 

토크가 시행될 때

"Run Screen"

은 표시 되지 않을 것입니다

.

모든

PRETORQUE

조임 .

PRETORQUE

BATCH

가 끝나면

 “OK. “TQ”

를 나타내는

 “Run Screen"

은 변경 될 것 입니다

. Final Torque

의 모든 조임

. Note: REHIT

조임이 거부되는 동

MIN PULSE COUNT

 final

토크를 받기 위해서 조절 될 필요가 있을지도 모릅니다

.

RAMP SPEED: HIGH, MED, LOW

 START PSI

로부터 공압 램프 스피드의 셋팅을 선택 되어질 수 있습니다

. START PSI

디폴트값은

 70 

PSI

입니다

.

이것은 런다운 스피드를 제어하고

,

토크의 분산을 방지한다

.

툴이 조임을

 “RUN” 

할 때,

TARGET TQ

가 도달 할 때까지

 PSI

최대

 PSI

까지

 RAMPED

될 것입니다

.

스피드는

 PSI

가 증가함으로써 선택 가능 합니다

.

다음

 ADMIN 

기능으로 가기 위해 스크롤 하세요

.

BACK

키를 누르면

 RUN 

스크린으로 복귀 할 것 입니다

.

14

PSI-C

Summary of Contents for PSI-C

Page 1: ...the equipment or described in this manual Stanley Assembly Technologies Applications Productivity Center 5800 Enterprise Court Warren MI 48092 3476 Tel 586 393 1100 Fax 586 393 1200 Toll Free in the US 1 877 787 7830 www stanleyworks com PSI C 0406 THE STANLEY WORKS ALL RIGHTS RESERVED G G G G G G G G G G G G G G G G G G rUzUlUjG 㟬䏭ⷸ㐐GἼ㷐ẠGᴴ G _XTXXG 䊀䆠 G_㵜G W 䝬G ࣜࣜࣜऌऄऋऊँࣶࣜࣜ ࣲࣩࣩࣴࣳࣳ ࣳࣤ堆ࣥࣜࣨࣜंࣽऔࣶࣜࣜ ࣩࣴ...

Page 2: ... Air Supply Requirement 6 Tool Compatibility and Transducer Pulse Tools 7 Layout and Operator Interface 8 Main Menu and Application Programming 9 Parameter Set Up 10 Test 11 Administration Functions 12 Error Proofing OK NOK 13 Normal Operation Run Mode 13 Inputs Outputs I O 14 RJ45 15 Networking 15 Service and Maintenance 15 Troubleshooting and Adjustments 16 2 PSI C ...

Page 3: ...Only allow suitably qualified personnel to install program or maintain this equipment and or system These persons must be knowledgeable of any potential sources of danger and maintenance measures as set out in the Installation Operations and Maintenance manual This product must be transported stored and installed as intended and maintained and operated with care to ensure that the product function...

Page 4: ...he standard configuration utilizes a CE approved power supply that is UL listed It consists of a wall mount 120VAC transformer with a 16VAC 50 Hz at 1 Amp power output Power supplies for other International standards Japan 110 v 50 Hz 1 Amp part 10565 Australia 240 v 50 Hz 1 Amp part 10566 United Kingdom 240 v 50 Hz 1 Amp part 10567 Europe 220 v 50 Hz 1 Amp part 10568 To Avoid Injury Plug power co...

Page 5: ... rated up to 7 amps at 48V AC DC Printer optional Internal Thermal Printer for documentation of cycle data onto individual labels 2 x 4 adhesive backed Serial Port RS 232 port RJ45 connector Interface Dual Line 0 5 LCD backlit 16 character Five button keypad Up Down Enter Menu Back ADMIN Back button Momentary for Batch reset hold down 2 sec for Over ride LED Indicators CYCLE OK NOK Indicators BATC...

Page 6: ...valve and will not allow air flow back thru the lubricator This type is not recommended for use with the ePro FSC The tool air hose cable for the EITP EITM and ESPT series of tools is called the GEMINI The GEMINI air hose includes an integral transducer cable and is available in 3 8 I D coiled or straight and available in many lengths A separate transducer cable is also available Prevent any unnec...

Page 7: ...he torque required If prevailing torque is present then an over sized tool may be required If you desire to utilize any other brand of standard pulse tool Uryu Atlas Copco etc contact your salesperson for a transducer attachment for your tool This allows use of these common tools to be controlled with the PSI C process controller wzpTjG䆮䔎 㦖G G㭒㣪䞲Gぢ ⰢG㞚 G㓺䌶ⰂGwlG䔎 㓺 G䗚㓺䒊ὒG 䢎Gᾦ䢮 㦚GṖ㰧 UG 䞲Gộ㦖G 㔶㦮G 㧒㯞ⰾ...

Page 8: ...45 REMOTE KEYPAD LIGHTS etc 12 24V I O INPUTS OUTPUTS POWER SOCKET ePro URYU option POWER SOCKET STD 3 8 NPT AIR OUTPUT GEMINI HOSE CONNECT I O SCHEMATIC DATA X FER NETWORK SERIAL ETHERNET or DCX PFCS 1 2 NPT AIR INPUT TRANSDUCER CABLE CONNECT GEMINI HOSE PSI C ...

Page 9: ...Installation and Use 9 11 10 20 23 22 4 7 5 19 6 17 9 8 18 13 15 24 27 30 32 1 21 3 34 35 12 33 25 29 28 26 2 31 16 36 37 38 ePro FSC Controller Assembly Assembly Part No 11024 PSI C PSI C ...

Page 10: ...creen Press the ENTER key and the ePro automatically checks and sets the ZERO and MAX values of the transducer connected TARGET TORQUE Enter the target torque of the application by scrolling up or down press ENTER HIGH LIMIT Scroll to set the upper torque specification press ENTER LOW LIMIT Scroll to set the low limit torque specification press ENTER BATCH COUNT Scroll up to set the number of fast...

Page 11: ...LETE CAL TRANSDUCER CHECKING CAL CAL TRANSDUCER CHECKING MAX PARAMETER 1 NOT SETUP SET TARGET TORQUE 50 0 NOM CAL VALUE TQ 75 0 CAL TRANSDUCER CHECKING ZERO CAL TRANSDUCER CHECKING MAX CAL TRANSDUCER COMPLETE SET HI LIMIT TORQUE 57 5 Use the UP DWN arrows to find the parameter set desired Press ENTER to select Default HI LO Limits are set to 15 of Torque Target 11 PSI C PSI C ...

Page 12: ...OPERATION FLOWCHART INITIAL SETUP FSC CONT SET BATCH TIMER SECOND S 4 SET BATCH COUNT COUNT 2 TQ 50 5 PS 2 CT 02 TIMER 004 This is the RUN screen SET LO LIMIT TORQUE 42 5 12 PSI C PSI C CONT ...

Page 13: ... the tool will run until TARGET TQ is achieved MAX PULSE COUNT This sets a maximum allowable PULSE COUNT before the cycle is REJECTED If a strip or cross thread occurs this can help detect the bad cycle It can also detect a failing pulse pack unit Press ENTER and LAST RUN and MAX PULSE CT setting will appear The setting can be tested at this point Watch the screen and run some good and bad cycles ...

Page 14: ...usually 50 60 of the specified final torque Press ENTER Note BATCH COUNT must be programmed for correct sequencing The Run Screen will now show PTQ when running the PRETORQUE or snug torque PRETORQUE all fasteners When PRETORQUE BATCH is finished OK The Run Screen will change to show TQ Final Torque all fasteners Note MIN PULSE COUNT may need to be adjusted to accept final torque while still rejec...

Page 15: ...START 65 START PSI PSI 50 ADMIN MENU START PSI ADMIN MENU DOWNSHIFT DOWNSHIFT TORQUE 50 0 JOINT CONDITION PULSES 0 ADJUST DOWNSHIFT PSI 35 START 50 DYN TQ 0 0 STATIC TQ 0 0 CAL CORRECT CAL 200 0 CONTINUED BELOW PULSE DELAY PULSE S 5 ADMIN MENU PULSE DELAY PRETRIGGER PT 00 0 A 00 0 ADMIN MENU PRETRIGGER ADMIN MENU MAX PULSE COUNT LAST RUN 32 MAX PULSES 200 ADMIN MENU MIN PULSE COUNT LAST RUN 37 MIN...

Page 16: ...0 UP SET DWN CLR ADMIN MENU CYCLE COUNTER CYCLE COUNTER CYCLES 0 ADMIN MENU BATCH COUNT SET BATCH COUNT COUNT 2 SET BATCH TIMER SECOND S 4 ADMIN MENU BATCH TIMER ADMIN MENU LO LIMIT ADJUST LO LIMIT TORQUE 43 2 ADJUST HI LIMIT TORQUE 52 8 ADMIN MENU HI LIMIT CONTINUED BELOW ADMIN MENU CYCLE DELAY SET CYCLE DELAY DELAY 1000 CONTINUED ON NEXT PAGE 16 PSI C PSI C CONT ...

Page 17: ...T ADMIN MENU TIME DATE 03 08 07 01 49 UP SET DWN EXIT SET TIME DATE MONTH 03 SET TIME DATE DAY 08 SET TIME DATE YEAR 07 CONTINUED ON NEXT PAGE ADMIN MENU STATS STATS SAMPLES 10 DATA UP CLR DWN DWNLOAD ADMIN MENU DATA DATA 28 800 8 N 1 DATA DATA CLEARED CONTINUED BELOW 17 PSI C PSI C CONT ...

Page 18: ... TQ 0 0 PRETORQUE THOLD 0 0 PRETORQUE PSI 50 0 ADMIN MENU ADMIN LOCK OFF LEARN ADMIN CODE CODE ADMIN MENU RAMP SPEED MED ADMIN MENU RAMP SPEED HI ADMIN MENU FILTER SET FILTER FREQ FREQ 1150 ADMIN MENU RAMP SPEED LOW UNIT IP ADDRESS 192 ADMIN MENU ETHERNET OPERATION FLOWCHART ADMIN MENU FSC CONT CONTINUED BELOW ADMIN MENU RAMP SPEED OFF 18 PSI C PSI C CONT ...

Page 19: ...OUT is recommended when only one PSET is being utilized Pressing the BACK button clears the batch The BATCH NOK output fires and turns on the red BATCH LED Pressing and holding the BACK button for 1 2 seconds puts the ePro in OVER RIDE mode OVER RIDE means that the system has full power without any torque control or shut off capabilities The ePro has a two line main display This shows the final TO...

Page 20: ...of either polarity I O SCHEMATIC OUTPUTS PIN 1 COMMON PIN 2 CYCLE OK PIN 3 CYCLE NOK PIN 4 BATCH OK PIN 5 BATCH NOK INPUTS PIN 6 DISABLE TOOL PIN 7 BATCH REJECT RESET PIN 8 MANUAL WRENCH ACCEPT PIN 9 PSET BIT 3 BINARY PIN 10 PSET BIT 2 PARAMETER PIN 11 PSET BIT 1 SELECT PIN 12 INPUT COMMON I O CONNECTOR PLUG OPTIONAL PART 11424 BATCH DISABLE BATCH BATCH 12 11 10 9 8 7 6 5 4 3 2 1 0 0 1 PS1 0 1 0 P...

Page 21: ...a Collection and Download If the ePro FSC has the optional DTU Data Transfer Unit part 10771 all parameter sets and rundown data from the last 700 readings per Pset is stored in the memory of the DTU The SigmaSIX Data Transfer Kit part 11556 can be used to download this data to a Microsoft Excel spreadsheet The kit includes the SigmaSIX Data Transfer Software Program and all cables and adapter req...

Page 22: ...led and the ePro is being converted to PFCS communication follow the instructions below PFCS EtherNET network card Remove jumpers from main control board JP1 and JP2 PFCS Serial network card Remove all jumpers from main control board JP1 and install jumpers onto all positions on JP2 Once the Data Collection Cable Assembly is correctly assembled Open the SigmaSIX Data Collection Software Program Se...

Reviews: