background image

See Fig, 16 & 17 showing the position of the grate
for wood burning and coal burning, note the position
of the riddling rod also.  

WARNING - DO NOT CHANGE GRATE POSITION
WHEN STOVE IS HOT.

CHANGING GRATE ORIENTATION

For best combustion of coal it is best to burn it on an
open grate as the ash needs to be frequently
removed to avoid a build up of ash on the grate.

For best combustion of wood it is best to use an
almost flat grate with approximately 3mm separation
between grate bars so that it can build up a bed of
ash as it burns.

The grate on the Lismore Stove can be changed
from a coal setting to wood burning setting.

The product is supplied in the coal burning setting,
this should not be changed if a mixture of fuels are
being used i.e. (coal, wood, peat, anthracite).  If
burning wood only, change the grate setting by
opening the ash door and remove the ash pan.  This
should reveal a hex head bolt on the left hand side
which should be removed, with the bolt removed the
riddling bar can now be moved to the wood burning
position. (See fig. 18)

The hex head bolt should now be re-inserted in the
alternative position which will lock the grate in the
wood burning position. See Fig.16.

USER INSTRUCTIONS

Riddling Rod

Wood Setting

Fig.16

Fig.17

Coal Setting

Riddling Rod

Fig.18

Hex Bolt

16

REFUELLING 

Riddle the fire by pulling the grate riddling knob
back and forward (See Figure 19). Before opening
the door, turn the thermostat knob to setting 4 as
this will help to eliminate any smoke or fly ash resi-
dent in the combustion chamber. Add fuel to fire,
close fire door and re-set the thermostat knob to
the required setting.

LIGHTING THE STOVE

1.

Open fire door and open the primary air 
inlet by turning the control knob on the back
of the stove fully clockwise to setting 4 on 
the thermostat.

2.

Open the secondary air inlet by pushing it 
fully back.

3.

Cover the grate with crumpled pieces of 
paper and lay 10-12 pieces of kindling on 
top of the paper towards the back of the 
firebox.

4.

Ignite and close the fire door.

5.

When the kindling is well alight open the fire
door and add more kindling of a larger size 
to sustain the  fire.

6.

Close the fire door.

7.

When a hot fire bed is established add 
the normal fuel.

8.

When well lighted, adjust the controls to 
give the required heat output.

Summary of Contents for Lismore

Page 1: ...should be supervised at all times and should not be allowed to touch the hot working surfaces while in use or until the appliance has thoroughly cooled When using the boiler stove in situations where...

Page 2: ...bles 11 16 Floor Protection 11 17 Plumbing 11 18 Pipe Thermostat 11 19 Regulations 11 20 Gravity Circuit 11 21 Injector Tee 12 22 Water Circuit Temperature 12 23 Flue Water Pipe Locations 13 24 Stove...

Page 3: ...TABLE OF CONTENTS PAGE NO 43 Cleaning a Matt Black Senotherm Stove 18 44 Frozen System 18 45 Prolonged Periods of Non Use 19 46 Fire Safety 19 47 Glass Replacement 19 48 CO Alarm 19 49 Exploded View 2...

Page 4: ...ed as per the requirements of the manual Failure to comply with the Installation requirements or Building Regulations will void your warranty Waterford Stanley reserve the right to replace any part du...

Page 5: ...egulations to have a carbon monoxide alarm fitted to any room with a solid fuel appliance Location 10 Clearance to combustible materials must be adhered to as described in the Clearance to Combustible...

Page 6: ...llow a build up of ashes in the ash pan as this will cause the grate to burn out prematurely Empty the ashpan when refuelling 7 Avoid slow burning of damp or unseasoned fuel as this will result in tar...

Page 7: ...be done in accor dance with current Standards and Local Codes It should be noted that the requirements and these publications may be superseded during the life of this manual Please refer to the curr...

Page 8: ...uld be at be at least 2300mm when measured horizontally and at least 1000mm when measured vertically see Fig 1 In circumstances where there are adjoining buildings structures roof openings there are a...

Page 9: ...550mm per each kw of rated output above 5kw should be provided where a flue draught stabiliser is used the total free area shall be increased by 300mm for each kw of rated output 9 All materials used...

Page 10: ...duct approval covers this appliance when installed in accordance with the manufactur er s instructions and relevant standards As there is currently no standard for Ducted Combustion Air Supply this do...

Page 11: ...oking on refu elling See Fig 7 REGULATIONS The plumbing must be in accordance with all relevant regulations and practices It must include a gravity circuit with expansion pipe open to the atmosphere T...

Page 12: ...id condensation on the boiler and return piping Fitting a pipe thermo stat to the flow pipe of the gravity circuit and wiring it into the pump control will ensure rapid circulation of the hot water In...

Page 13: ...ly to be used on the stove and warn them to use only the recommended fuels for the stove Advise the user what to do should smoke or fumes be emitted from the stove The customer should be warned to use...

Page 14: ...e a stove provides 2kW to the room and 8kW to the boiler and if the thermostatic damper shuts down the air supply to provide 4kW to the boiler then the heat to room will decrease pro portionally to 1k...

Page 15: ...gs 1 BSP Max Water Pressure 2 Bar Efficiency 76 3 76 8 Model Energy Efficiency Class Heat Output to Room Heat Output to Water Energy Efficiency Index Preferred Fuel Nominal Heat Output Net Efficiency...

Page 16: ...18 The hex head bolt should now be re inserted in the alternative position which will lock the grate in the wood burning position See Fig 16 USER INSTRUCTIONS Riddling Rod Wood Setting Fig 16 Fig 17 C...

Page 17: ...the boiler cleaning plate The boiler cleaning plate can also be removed when cleaning the chimney if the flue pipe is fitted to the back outlet Fig 21 PERIODIC MAINTENANCE Adjusting the Door Catch Ove...

Page 18: ...possibility that the water system may be frozen do not attempt to light the stove until you are certain there is no ice in the system possibly causing a blockage VITREOUS ENAMEL CLEANING General clean...

Page 19: ...s and carefully remove the broken glass c Clean the glass recess in the door d Replace the sealing rope in the door if necessary e Tighten screws f Replace glass only with ceramic glass 5mm thick See...