4
DIMENSIONS
A
B
C
D
E
F
G
H
J
K
L
M
N
METRIC
915
920
530
560
300
1047
130
325
525
190
1475 1” BSP 150
(millimetre)
IMPERIAL
36
36
1
/
4
20
7/ 8
22
11
3/ 4
41
1/ 4
5
1/8
12
3
/
4
20
5/8
7
1
/
2
58
1”BSP
6
(inches)
Female
FEATURE
METRIC
IMPERIAL
HOT PLATE
555 x 325
22 x 13
ROASTING OVEN
400W x 320H x 410D
16W x 12
1
/
2
H x 16D
SIMMERING OVEN
400W x 225H x 410D
16W x 9H x 16D
SPECIFICATION
This appliance has been tested and approved in accordance with the Gas Appliance Directive (90/396/EEC),
the Low Voltage Directive (72/23/EEC) and the Electromagnetic Compatibility Directive (89/336/EEC) as
amended.
Differential Pressure Across the Boiler
Note: Water temperature rise for above test recorded at 16°C.
Design flow rate through the boiler
23 Litres / min. (G.P.M)
Static differential across the boiler
52 mbar (21” W.G.)
Dynamic pressure differential across the boiler
6 mbar (2.41” W.G.)
Note: dimensions stated below may be subject to
a /- variation