PROSET XT3 & XT4 NOSE ASSEMBLIES – 71220-16100, 71230-15800 & 71230-16100
IMPORTANT
Read the safety warnings listed in the ProSet
®
XT3 and ProSet
®
XT4 Instruction Manual carefully before putting
into service.
IMPORTANT
The air supply must be turned off or disconnected before fitting or removing the nose assembly.
Part Number: 71220-16100
Item Part Number Description
Qty
1
07340-00306 Nose Casing
1
2
07003-00067 O Ring
1
3
07612-02003 Jaw Housing
1
4
71220-16120 Jaws (3 pcs)
1 Set
5
07498-04502 Jaw Spreader
1
6
07498-03003 Buffer
1
7
07500-00418 Jaw Pusher Spring
1
8
07340-00327 Locking Ring
1
Part Number: 71230-16100
Item Part Number Description
Qty
1
07340-00306 Nose Casing
1
2
07003-00067 O Ring
1
3
07612-02003 Jaw Housing
1
4
71230-16101 Jaws (3 pcs)
1 Set
5
07498-04502 Jaw Spreader
1
6
07498-03003 Buffer
1
7
07500-00418 Jaw Pusher Spring
1
8
07340-00327 Locking Ring
1
Part Number: 71230-15800
Item Part Number Description
Qty
1
07340-00306 Nose Casing
1
2
07003-00067 O Ring
1
3
07612-02003 Jaw Housing
1
4
07612-02002 Jaws (3 pcs)
1 Set
5
07498-04502 Jaw Spreader
1
6
07498-03003 Buffer
1
7
07500-00418 Jaw Pusher Spring
1
8
07340-00327 Locking Ring
1
FITTING INSTRUCTIONS
Item numbers in
bold
refer to nose assembly components in the tables and diagram above.
•
The air supply must be disconnected.
•
If necessary, remove the complete nose assembly 76003-15000 as described in the ProSet
®
XT3 and ProSet
®
XT4
instruction manual.
•
Fit the XT3 Adapter Kit 76003-20400 to the tool piston and then tighten the locknut (71210-02103) against it using
spanners.
•
Lightly coat Jaws (
4
) with Moly Lithium grease*.
•
Drop Jaws (
4
) into Jaw Housing (
3
).
•
Insert Jaw Spreader (
5
) into Jaw Housing (
3
).
•
Locate Buffer (
6
) on Jaw Spreader (
5
).
•
Locate Spring (
7
) onto Jaw Spreader (
5
).
•
Fit Locking Ring (
8
) onto the jaw spreader housing from XT3 Adapter Kit 76003-20400.
•
Holding tool pointing down, screw the assembled jaw housing onto the jaw spreader housing and tighten with
spanner.
•
Screw the nose tip into Nose Casing (
1
) and tighten with spanner.
•
Place Nose Casing (
1
) with O Ring (
2
) over Jaw Housing (
3
) and screw onto the tool, tightening with spanner.