GB & IE version
49
5.0 Technical Data
ARGON F900 Natural Gas
Double Burner
Gas type
G20
G20/G25
G20/G25
G25
I2H,I2E
I2E+
I2ELL
I2L
Supply Pressure
mbar
20
20 / 25
20
25
Nominal Heat Input Gross (Hs)
kW
10
10 / 9.1
9.1 / 8.0
9.1
Nominal Heat Input Nett (Hi)
kW
8.9
8.9 / 8.0
8.0 / 7.3
8.0
Consumption
m³/hr
0.94
0.94 / 1.05
0.94 / 0.93
1.05
Burner Pressure (hot)
mbar
18.5
18.5 / 23.0
18.5 / 18.4
23.0
Injector Marking
400 (Front) & 280 (Rear)
Pilot
446.1385.44
Efficiency Class
1
Nox Class
5
High Heat Output
– 7.2 kW
Low Heat Output
– 2.5 kW
ARGON F900 LPG Gas
Double Burner
Gas type
G30/G31
G31
I3B/P(30/50)
I3+
I3P(37,50)
I3P(30)
Supply Pressure
mbar
30/50
28-30/37
37/50
30
Nominal Heat Input Gross (Hs)
kW
8.8
8.8
8.7
8.0
Nominal Heat Input Nett (Hi)
kW
7.8
7.8
7.7
7.1
Consumption
m³/hr
0.25
0.25
0.3
0.26
Burner Pressure (hot)
mbar
28.0
28.0
36.5
29.9
Injector Marking
140 (Front) & 100 (Rear)
Pilot
446.1385.24
Efficiency Class
1
Nox Class
5
High Heat Output
– 6.3 kW
Low Heat Output
– 2.2 kW