10
Fig.7
* In addition, the terminal should not be nearer than 300mm to an opening in the building fabric formed for the purpose of
accommodating a built in element such as a window frame.
Terminal Position
Distance
(mm)
Terminal Position
Distance
(mm)
A*
Directly below an opening, air brick,
opening window etc.
600
I
Above ground roof or balcony level
300
B
Above an opening, air brick, opening win-
dow etc.
300
J
From a surface facing the terminal
600
C
Adjacent to an opening, air brick, open-
ing window etc.
400
K
From a terminal facing the terminal
600
D
Below gutters, soil pipes or drain pipes
300
L
From an opening in the car port (e.g.
door, window into the dwelling)
1200
E
Below eaves
300
M
Vertically from a terminal on the same
wall
1500
F
Below balconies of car port roof
600
N
Horizontally from a terminal on the same
wall
300
G
From a vertical drain pipe or soil pipe
300
P
From a vertical structure on the roof
600
H
From an internal or external corner
600
Q
Above intersection with roof
150
Fig.5