ENERPAC THQ-700 SERIES - 700 BAR/10,000 PSI MAX.
ENERPAC THQ-700 SERIES - 700 BAR/10,000 PSI MAX.
B
A
ENERPAC THC-700 SERIES - 800 BAR/11,600 PSI MAX.
B
A
ENERPAC THC-700 SERIES - 800 BAR/11,600 PSI MAX.
Figure 6, Hose Details
(-E) Pumps
Retract
Advance
(-Q) Pumps
Retract
Advance
Pump Valve
Torque Wrench
4.2 Pump Mounting (See Figure 4)
Refer to Figure 4 for mounting dimensions to secure the pump
to a fi xed surface.
A
B
C
(Note: Reservoir viewed from below)
1- 2 Gal. (4-8 Liter) Reservoir
A
3.75 inch (95 mm)
B
9.00 inch (229 mm)
C
tapped holes, M8 x 1.25
0.25 inch (6 mm) deep
Figure 4, Mounting Dimensions
4.3 Electrical Connections
T
HE
P
UMP
I
S
F
ACTORY
E
QUIPPED
W
ITH
T
HE
C
OMMON
E
LECTRICAL
P
LUG
F
OR
A G
IVEN
V
OLTAGE
. A
LTERING
T
HE
P
LUG
T
YPE
S
HOULD
O
NLY
B
E
D
ONE
B
Y
A Q
UALIFIED
E
LECTRICIAN
, A
DHERING
T
O
A
LL
A
PPLICABLE
L
OCAL
A
ND
N
ATIONAL
C
ODES
.
1. The disconnect and line circuit protection to be provided
by customer. Line circuit protection to be 115
%
of motor
full load current at maximum pressure of application (see
Figure 1).
2. For more information, refer to pump name plate for power
rating.
4.4 Oil Level
Check the pump oil level prior to start-up, if necessary add oil by
removing the SAE #10 plug from the cover plate (see Figure 3).
The reservoir is full when the oil level is as shown in Figure 5.
Reservoir is full when
oil level is here
Figure 5, Sight Glass
IMPORTANT:
Add oil only when all system components are fully
retracted, or the system will contain more oil than the reservoir
can hold.
4.5 Connect Hydraulic Hoses
Connect hoses as shown in Figure 6.
1. (-E) Pump type for Enerpac SQD and HXD torque wrenches:
Be sure to use hoses marked “Enerpac THC-700 Series
- 800 Bar/11,600 psi max.” The couplers on these hoses
are “polarized” at the factory to ensure correct wrench
operation.
A. Hose and wrench female couplers. Hand tighten threaded
coupler lock rings, no tools are required.
B. The (-E) pump’s female couplers are self locking, press
mating couplers together until coupler lock ring snaps
forward. To disconnect, twist coupler lock ring clockwise and
push away from connection.
2. (-Q) Pump type for Enerpac S and W torque wrenches and
other brands: Use hoses marked “Enerpac THQ-700 series
- 700 bar/10,000 psi max.” Couplers must be polarized per
Figure 6 for correct wrench operation. Ensure couplers are
fully engaged and tightened before operating. Partial coupler
engagement will prevent proper wrench operation.
WARNING:
When using (-Q) pumps with multi-wrench
manifolds, ensure all unused couplers have the
protective caps fully installed before starting pump.
Note:
When the wrench is fi rst connected to the pump, air will
be trapped in the hydraulic circuit. Remove air by placing wrench
and straightened hoses below pump, operate wrench without
load until it rotates without hesitation.
Summary of Contents for 76501-02000