21
•
DIAGNOSE
–
This screen allows the operator to troubleshoot connection issues between the placing tool and the pump
by displaying if the microprocessor has received a signal from the trigger button. No signal indicates the problem is most
likely with the trigger or trigger control cord.
SCREEN 12
BAR
DIAGNOSE
00001
00001
BAR displayed when placing tool trigger button is not activated.
01001
BAR displayed when the placing tool trigger is pressed.
3.4
RETURN TIMER SETTING
Note: This is not applicable to pump models 76506-02000 and 76507-02000
–
refer to
section 3.6.
•
The pump has an adjustable Return Timer that allows operator to set the length of time that the motor will run, after
releasing the trigger or achieving th
e ‘High Pressure’ value, before swit
ching to idle mode.
•
The timer can be set at any value between 5 and 20 seconds, but must be adjusted to allow the placing tool piston
sufficient time to fully return before switching the motor off.
The following timer settings are recommended for the Avdel
®
range of placing tools and pumps.
PUMP RETURN TIMER SETTING
TOOL PART NUMBER
73430-02000 73432-02000 73434-02000 73435-02000
TOOL MODEL
AV
™
10
AV
™
15
AV
™
30
AV
™
50
ZU4 Pump
–
Timer Setting
5 seconds
5 seconds
8 seconds
10 seconds
ZE4 Pump
–
Timer Setting
5 seconds
5 seconds
8 seconds
10 seconds
ZE6 Pump
–
Timer Setting
5 seconds
5 seconds
5 seconds
6 seconds
•
The process below explains how to correctly set the Return Timer.
•
Connect the unit to the power supply and switch on as described on pages
13
and
14
.
•
Press the MENU
button on the LCD screen until the ‘
RET TIME
’ menu is displaye
d.
•
Use the Up and Down Arrows to adjust to the timer in 1 second intervals to the desired value.
•
Save the setting and return t
o the ‘A
VDEL
’ display by pressing an
d holding the MENU button for 2 seconds. The timer is
now set.